We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 6.5 mm | PVC, Box of 10 units (Ref. ETA065C02A2)

99,80 €

Reinforced orotracheal endotracheal tube with cuff and Murphy eye, internal diameter 6.5 mm, manufactured from medical-grade polyvinyl chloride (PVC) with anti-kink spiral reinforcement. Designed for positive-pressure ventilation and administration of anaesthesia when the use of a face mask is not feasible, it maintains a patent and stable airway during critical procedures, head and neck surgery or special positioning. Includes sealing cuff with pilot balloon, universal 15 mm connector and radiopaque marker. Supplied in a box of 10 units, ideal for ICU, operating theatre and emergency departments. Ref. ETA065C02A2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETA065C02A2

Description

1. Introduction

The reinforced oral endotracheal tube with cuff and Murphy eye, 6.5 mm (ref. ETA065C02A2) is the airway solution that anaesthesia, intensive care and emergency services need when face mask ventilation is not viable. Its spiral-reinforced wall makes it the reference option when patient movement, frequent repositioning or head and neck surgery are anticipated, ensuring a patent lumen at all times. It is supplied in a box of 10 units for restocking intubation trolleys, ICU bays, operating theatres and emergency services.

2. Technical explanation of the device

In orotracheal intubation, the tube is inserted orally through the glottis until its distal end is positioned in the trachea, below the vocal cords. The reinforced body (spiral integrated into the PVC wall) prevents collapse of the lumen under external compression, patient biting or kinking, maintaining airway patency throughout the procedure. The sealing cuff, inflated via the pilot balloon, seals the tracheal lumen and allows positive-pressure ventilation without leaks, while also helping to prevent aspiration of secretions. The Murphy eye, a lateral opening at the distal tip, acts as a safety pathway: if the main opening were obstructed by contact with the tracheal or bronchial wall, respiratory flow continues through this opening, preventing total occlusion. The universal 15 mm connector (ISO 5356-1) allows direct connection to the ventilator, anaesthesia circuit or resuscitation bag.

3. Technical Specifications

The specifications correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference ETA065C02A2
Type Reinforced oral endotracheal tube with cuff
Internal diameter (ID) 6.5 mm (indicative 26 Fr)
Access route Oral (orotracheal)
Material Medical-grade polyvinyl chloride (PVC), transparent
Reinforcement Integrated helical spiral, kink-resistant
Sleeve Cuffed, inflated via pilot balloon
Murphy eye Present (distal lateral safety opening)
Connector Universal 15 mm (ISO 5356-1)
Radiopacity X-ray contrast line
Latex Natural rubber latex-free
Sterility Sterile, individually packaged (ethylene oxide, EO)
Use Single-use, non-reusable
Indications Positive pressure ventilation and anaesthesia administration
Presentation Box of 10 units

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the manufacturer’s declaration of conformity and CE marking on each supplied batch before use in procedures.

4. Equivalences and Cross-References

Reference ETA065C02A2 is a proprietary code of the Cahnos range; it does not correspond to an official manufacturer part number published in public sources, so it should be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code. There is no manufacturer-validated equivalence table for this reference; consult the Cahnos technical department before use in tendering. By clinical indication (reinforced oral endotracheal tube with cuff and Murphy eye, ID 6.5 mm) this product is comparable at category level (not 1:1 interchangeable) with spiral-reinforced tubes from manufacturers such as Teleflex (Rüsch® Flex / Sheridan®), Medtronic (Shiley™), ICU Medical (Portex® Blue Line®) and Intersurgical: all these brands offer reinforced oral cuffed tubes to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and balloon characteristics, so they must be compared specification by specification before replacing a specific product. Third-party references such as the Rüschflex® or the 6.5 mm Safety-Flex line are cited in the market; their codes must be verified against the manufacturer before any substitution (not verified in primary sources at the time of writing this datasheet).

Comparable within the Cahnos catalogue in the same ID 6.5 mm size (not 1:1 interchangeable):

Reference Description
ETAM65C02A1 Reinforced oral endotracheal tube with cuff, insertion guide and Murphy eye, ID 6.5 mm
ETA065002A2 Reinforced oral endotracheal tube without cuff with Murphy eye, ID 6.5 mm
ETAN65C02 Oral endotracheal tube with cuff and Murphy eye, without reinforcement
ETSL65C02 Oral endotracheal tube with cuff and subglottic suction lumen
ETPN65C02 Preformed nasal tracheal tube with cuff and Murphy eye

5. Selection tips and variants of interest

  • The 6.5 mm ID is intended for adolescent or small-build adult patients; as a general guide, tubes of 7.0 to 9.0 mm are used in adults depending on build, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
  • Verify the integrity of the cuff and pilot balloon before insertion and control the sealing pressure with a manometer, keeping it within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm the service protocol).
  • The cuffed reinforced tube is especially indicated when frequent repositioning, prone positioning, head and neck surgery or risk of kinking are anticipated.
  • If intubation is to be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL65C02); if an integrated insertion guide is desired, select version ETAM65C02A1; for nasal approaches, the preformed ETPN65C02.
  • For volume conditions, samples or hospital supply lead times, contact the technical and commercial department of Cahnos.

Additional information

Reference

ETA065C02A2

Product type

Reinforced oral endotracheal tube with cuff

Inner diameter

6.5 mm

Access route

Oral (orotracheal)

Material

Medical-grade polyvinyl chloride (PVC)

Reinforcement

Integrated anti-kink helical spiral

Sleeve

Cuffed, with pilot balloon

Connector

Universal 15 mm (ISO 5356-1)

Radiopacity

X-ray contrast line

Latex

Natural rubber latex-free

Sterilisation

Ethylene oxide (EO), sterile

Use

Single-use, non-reusable

Indicative patient

Adolescent / adult of small build

Presentation

Box of 10 units

Regulatory standard

ISO 5361 / ISO 5356-1

Ojo murphy

With Murphy's eye

Reviews

There are no reviews yet.

Be the first to review “Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 6.5 mm | PVC, Box of 10 units (Ref. ETA065C02A2)”

Your email address will not be published. Required fields are marked *