Description
1. Commercial Introduction
The reinforced orotracheal endotracheal tube with cuff of 7.0 mm (Ref. ETA070C02A2) is the solution that your anaesthesia, intensive care, emergency or resuscitation department needs to ensure a patent, stable and reliable airway in critical procedures. Its medical-grade PVC construction and reinforced structure provide the necessary resistance to keep the lumen open even under external pressure, patient mobilisation or frequent repositioning. A professional choice, available in a box of 10 units and with immediate delivery from Cahnos.
2. Technical explanation of the device
The tube is inserted orally through the glottis into the trachea and is connected at its proximal end to the ventilator, the anaesthesia circuit or the resuscitation bag via the universal 15 mm connector (ISO 5356-1). The high-volume, low-pressure cuff, integrated at the distal end, provides an airtight seal against the tracheal wall, allowing positive-pressure ventilation for prolonged periods while minimising the risk of pressure injury to the mucosa.
The tube wall incorporates an anti-kink reinforcement spiral that provides high resistance to compression and torsion: the airway remains patent even with head movement, cervical flexion-extension or postural changes, situations frequently encountered in neurosurgery, head and neck surgery or prone position ventilation. The Murphy eye, a lateral opening at the distal tip, acts as a backup ventilation pathway: if the main lumen becomes obstructed by secretions or kinking, airflow continues through this opening. The radiopaque line with depth graduation facilitates radiographic position control.
3. Technical Specifications
| Reference Cahnos | ETA070C02A2 |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 7.0 mm |
| Configuration | Reinforced, with cuff |
| Sleeve | High volume and low pressure |
| Murphy eye | Present, distal lateral safety orifice |
| Reinforcement | Helical anti-kink spiral integrated into the wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Connector | Universal 15 mm (ISO 5356-1) |
| Marking | Radiopaque line and depth graduation |
| Use | Single-use, non-reusable |
| Sterilisation | Ethylene oxide (EO), sterile supply |
| Presentation | Box of 10 units |
| Main indication | Positive-pressure ventilation and administration of anaesthesia when the use of a face mask is not possible. |
This size belongs to the range of oral endotracheal tubes reinforced with cuff from Cahnos (series ETA…C02A2), available in several diameters to complete the department’s stock:
| Reference | ID (mm) |
| ETA065C02A2 | 6.5 |
| ETA070C02A2 (this product) | 7.0 |
| ETA075C02A2 | 7.5 |
| ETA080C02A2 | 8.0 |
| ETA085C02A2 | 8.5 |
| ETA090C02A2 | 9.0 |
| ETA095C02A2 | 9.5 |
| ETA010C02A2 | 10.0 |
4. Equivalences and Cross-References
The reference ETA070C02A2 is a proprietary code from the Cahnos catalogue, so it does not have an equivalent factory code published by a specific manufacturer. For this specific configuration (oral, reinforced, with cuff, with Murphy eye, ID 7.0 mm) there is no manufacturer-validated equivalence table in the official sources consulted; the following references are offered as functional category comparison, not 1:1 interchangeable, and must be confirmed with the technical department before use in tendering:
| Manufacturer | Reference | Description | Key difference |
| Dahlhausen | 44.000.20.070 | Spiral-reinforced endotracheal tube with cuff, ID 7.0 mm | Same family, material, size and reinforcement; comparable by category, pending field-by-field documentary confirmation. |
| Endosid® (Asid Bonz) | 849070 | Spiral-reinforced endotracheal tube with Murphy eye and cuff, ID 7.0 mm | Same clinical concept, size and configuration; pending documentary confirmation. |
| Teleflex (Rüsch® / Sheridan) | Reinforced series with cuff | Reinforced oral endotracheal tubes with cuff | Comparable at category level; verify measurements, material and geometry per manufacturer. |
Important notice: there is no manufacturer-validated equivalence table for this reference; any specific cross-reference must be consulted with the technical department of Cahnos before use in tendering. These alternatives are not 1:1 interchangeable and must be verified field by field (measurements, material, geometry and regulations) before replacing the product.
5. Selection tips and variants of interest
The 7.0 mm ID falls within the usual adult intubation range (indicative recommendation: 7.0–8.0 mm depending on sex and build) and is one of the most commonly used sizes in adult patients, especially in women and adults of medium build. As a general guideline, always select the largest size compatible with the patient’s anatomy to minimise leaks and avoid mucosal damage.
The cuffed configuration is the appropriate option when an airtight seal is required in prolonged ventilation or sustained positive pressure; if the protocol prefers to avoid the inflatable balloon in procedures of limited duration, consider the uncuffed variant of the same size (Ref. ETA070002A2). To standardise the airway trolley, complete the supply with the adjacent sizes in the range (ETA075C02A2, ETA080C02A2) and the available paediatric sizes. Single-use device: discard it after removal and follow the centre’s healthcare waste management protocols. For institutional orders, supply contracts or formalised quotations, contact our technical-commercial department.