Description
1. Introduction
The Contiplex® C NRFit® Set from B. Braun is the continuous regional anaesthesia solution that simplifies perineural catheter placement: a patented catheter-over-needle (catheter-over-needle) system that combines the simplicity of a single puncture with the analgesic power of a catheter. Designed for anaesthesiology departments, pain units and enhanced recovery protocols (ERAS), it allows continuous blockade of plexuses and peripheral nerves with less trauma, less complexity and greater patient comfort, since the puncture cannula is of fine gauge (25 G).
All components that come into contact with the infusion line incorporate the NRFit® connection, in accordance with standard ISO 80369-6, which prevents any incorrect connection with Luer systems from other lines.
2. Technical explanation of the equipment and procedure
The set is based on a differentiating design: the Contiplex® C puncture needle (25 G) is mounted inside the Contiplex® C catheter (19 G) and both components advance together during puncture. Once the target structure is located using neurostimulation and/or ultrasound imaging (dual guidance), the needle is removed and the echogenic catheter remains in final position in a single step, without the need to thread or advance it secondarily. This reduces the number of manoeuvres, tissue trauma and the risk of catheter displacement.
The echogenic catheter offers excellent visibility under ultrasound control, facilitating verification of local anaesthetic spread around the nerve. The system is completed with the C-grip (control handle during puncture), the Perifix® catheter connector, the Perifix® 0.2 µm filter, the Perifix® PinPad (adhesive fixation of the filter) and the infusion extension line, all with NRFit® connection in accordance with ISO 80369-6. It also includes an adhesive label identifying the catheter location.
3. Technical Specifications
| System | Catheter over needle (catheter-over-needle) for continuous plexus and peripheral nerve block (cPNB) |
| Contiplex® C puncture needle | 25 G – outer diameter 0.53 mm – length 190 mm – 15° faceted bevel – graduated every 1 cm – NRFit® connection |
| Contiplex® C catheter | 19 G, echogenic, advances with the needle during puncture |
| Guidance | Neurostimulation and/or ultrasound imaging (dual guidance) |
| Connection | NRFit® according to ISO 80369-6 (needle, catheter connector, filter and extension line) |
| Filter | Perifix® 0.2 µm with NRFit® connection |
| Fixation | Perifix® PinPad (adhesive) |
| Additional components | Adhesive label identifying the catheter location, C-grip, Perifix® catheter connector, infusion extension line with NRFit® connection |
| Sterilisation | Ethylene oxide (EO), sterile packaging |
| Use | Single-use |
| Presentation | Box of 5 units |
Kit contents (included components)
- Contiplex® C puncture needle (25 G) with NRFit® connection.
- Contiplex® C echogenic catheter (19 G).
- Adhesive label identifying the catheter location.
- C-grip.
- Perifix® catheter connector with NRFit® connection.
- Perifix® 0.2 µm filter with NRFit® connection.
- Perifix® PinPad.
- Infusion extension line with NRFit® connection.
Available references
| Reference | Description | Presentation |
|---|---|---|
| 4898115NR | SET CONTIPLEX C NRFIT | Box of 5 units |
4. Equivalences and Cross-References
The reference 4898115NR (also coded as BBR4898115NR) corresponds to the Contiplex® C set with NRFit® connection, which differs from the standard Contiplex® C version exclusively by incorporating NRFit® safety connectors (ISO 80369-6) throughout the infusion line: the version with Luer connection (Contiplex® C, refs. 4898115 / 4898130) performs the same clinical function but is not interchangeable 1:1 with NRFit® systems.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Observations |
|---|---|---|---|---|
| B. Braun | Contiplex® C (Luer version, without NRFit®) | 4898115 / 4898130 | Comparable by category (not interchangeable 1:1) | Same catheter-over-needle system, but with standard Luer connection: incompatible with NRFit® syringes and systems ISO 80369-6. |
| B. Braun | Contiplex® S Ultra 360 NRFit® | — | Comparable by category (not interchangeable 1:1) | Same NRFit® family with catheter through needle (18 G) and 360° echogenic needle. |
| B. Braun | Contiplex® Tuohy Ultra 360 NRFit® | — | Comparable by category (not interchangeable 1:1) | NRFit® set with Tuohy bevel for continuous catheterisation. |
| Teleflex (Arrow) | StimuCath™ Continuous Peripheral Nerve Block Set | AB-19608-S | Comparable by category (not interchangeable 1:1) | Complete continuous block system with stimulating catheter and introducer; verify configuration and references before substituting. |
There is no equivalence table officially validated by the manufacturer for cross-referencing this reference with other brands; the indicated correspondences have been checked against the official catalogue and are offered as guidance by category. Before any substitution in tenders or by alternative brand, consult the technical department to verify gauges, lengths and connector compatibility.
5. Selection tips and variants of interest
- NRFit® connection: choose this version if your hospital works with NRFit® syringes, three-way stopcocks and infusion circuits (ISO 80369-6). If your equipment park is Luer, consider the standard Contiplex® C version.
- Guidance technique: the set is prepared for dual guidance (ultrasound imaging + neurostimulation); the 15° faceted bevel of the 25 G needle offers fine and atraumatic sliding, suitable for superficial approaches and patients with delicate tissue.
- System advantage: by advancing needle and catheter together, placement is performed in a single step, reducing manoeuvres and the risk of catheter displacement compared with conventional catheterisation systems.
- House variants: for continuous block with needle through 18 G catheter, consider the Contiplex® S Ultra 360 NRFit® or Contiplex® Tuohy Ultra 360 NRFit® sets, which share NRFit® connection and echogenic technology.
- Compatibility: for an optimal and safe connection between the neurostimulator and the needle, the manufacturer recommends combining products of the same brand; consult the instructions for use (IFU).
- Single-use: sterile single-use product; check the integrity of the packaging and the expiry date before each procedure.