We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Spinocan® NRFit® Spinal Needle B. Braun – Quincke Bevel 22G–29G with NRFit® Connection (ISO 80369-6) for Spinal Anaesthesia and Lumbar Puncture

Price range: 70,46 € through 660,79 €

Spinal needle with Quincke cutting bevel and NRFit® connection (ISO 80369-6) for spinal anaesthesia and diagnostic lumbar puncture. Spinocan® range from B. Braun in gauges from 22G to 29G, with transparent prism hub that instantly confirms cerebrospinal fluid reflux and colour-coded obturator stylet. Medical-grade stainless steel cannula, sterile and single-use. Presentation in a box of 25 units, with B2B supply for anaesthesiology services, operating theatres and pain units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BBR-SPINOCAN-NRFIT

Description

1. Introduction

The Spinocan® NRFit® range from B. Braun is the established reference in anaesthesiology and operating theatre services for access to the subarachnoid space using a Quincke cutting bevel needle, now with NRFit® connection (ISO 80369-6): the small-bore connector system that prevents accidental connection to intravenous or infusion lines, enhancing patient safety in regional anaesthesia. Available in gauges from 22G to 29G, it is presented in a box of 25 units in individual sterile packaging, covering the needs of hospitals, clinics and diagnostic centres.

2. Technical explanation of the procedure

Subarachnoid or spinal anaesthesia involves the administration of local anaesthetic into the cerebrospinal fluid (CSF) of the subarachnoid space, achieving a rapid, deep and reliable sensory and motor block, indicated for abdominal, urological, trauma and orthopaedic surgery, obstetrics and lower limbs. The Quincke bevel tip, with its cutting geometry, creates a clean, controlled incision in the dura mater, facilitates advancement through the ligamentous planes and allows the characteristic dural ‘click’ to be felt. The colour-coded obturator stylet maintains lumen patency and prevents tissue entry; the transparent hub with prism shines silver before reflux and becomes transparent when CSF passes, confirming correct cannulation before injection. The NRFit® connection is designed to prevent cross-connection with other medical systems, in accordance with ISO 80369-6. It is a sterile, single-use product, ensuring maximum protection against cross-infection.

3. Technical Specifications

Characteristic Specification
Needle type Bevelled spinal needle (Quincke cutting tip)
Available sizes 22G to 29G
Common lengths 40 / 75 / 88 / 120 mm depending on gauge
Connection NRFit® (ISO 80369-6), small cone not connectable to Luer
Hub Transparent with prism that reflects CSF outflow
Mandrel Stainless steel with colour coding
Material Medical-grade stainless steel cannula
Application Spinal anaesthesia and diagnostic lumbar puncture
Sterility Sterile (EO), single-use, individual blister pack
Contains PVC / Latex / DEHP No / No / No
Presentation Box of 25 units

Spinocan® range (standard catalogue references B. Braun; the NRFit® version maintains the same dimensions with ISO 80369-6 connection):

Reference Gauge Size Identification colour Introducer
4507401-13 22G 0.70 × 40 mm (1 1/2″) Black No
4507754-13 22G 0.70 × 75 mm (3″) Black No
4507908-01 22G 0.70 × 88 mm (3 1/2″) Black No
4506090-13 22G 0.70 × 120 mm (4 3/4″) Black No
4505905-01 25G 0.53 × 88 mm (3 1/2″) Orange No
4502906-01 26G 0.47 × 88 mm (3 1/2″) Brown No
4503902-01 27G 0.42 × 88 mm (3 1/2″) Grey No
4502140-13 27G 0.42 × 120 mm (4 3/4″) Grey No
4501900-13 29G 0.35 × 88 mm (3 1/2″) Red Yes
4501918-13 29G 0.35 × 120 mm (4 3/4″) Red No

Specific NRFit® references are confirmed on request with the technical-commercial team at Cahnos according to the required gauge and length.

4. Equivalences and Cross-References

B. Braun does not publish an official cross-reference table for the Spinocan® range; equivalences between brands must be verified field by field before use in tenders. By tip family (Quincke cutting bevel, 27G gauge), the following references from another manufacturer are comparable by category (not interchangeable 1:1):

Manufacturer / Brand Family / Model Code / SKU Equivalence Level Technical Differences / Remarks
Dahlhausen Quincke bevel spinal needle, 27G × 3.5″ / 89 mm 76.111.27.035 Comparable by category (not interchangeable 1:1) Same Quincke cutting tip family and 27G gauge; very similar length (89 mm); connector and hub according to manufacturer.
Dahlhausen Quincke bevel spinal needle, 27G × 4.72″ / 120 mm 76.111.27.120 Comparable by category (not interchangeable 1:1) Same Quincke tip family and 27G gauge; longer length (120 mm), suitable for greater insertion travel.

Technical warnings: the Quincke cutting tip is not equivalent to the atraumatic pencil-point tip (Pencan®, Whitacre, Sprotte): the incidence of post-dural puncture headache is different and they must not be substituted for each other without clinical evaluation. The BD Quincke 27G needle of 0.4 × 90 mm is comparable by category, but its specific code is pending confirmation with the manufacturer before citing it. Always verify before substitution: gauge, length, tip type, presence of introducer, connector (Luer vs. NRFit®, ISO 80369-6) and sterility of the actual product. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.

5. Selection tips and variants of interest

The 27G × 88 mm gauge is the most requested standard variant for lumbar approaches in adults of medium build, prioritising minimal dural trauma within the fine range. If you require greater injection flow and rigidity, consider intermediate gauges (25G, 26G) or 22G; if you work with special populations or need greater insertion travel, consult the long lengths (120 mm) and the versions with introducer in the range. The NRFit® connection is the recommended option in departments that have already implemented the ISO 80369-6 connector system or in procedures where the risk of erroneous connections with intravenous infusion material is to be eliminated. To minimise the risk of post-dural puncture headache in outpatients or early discharge patients, the department may consider the atraumatic pencil-point tip family (Pencan®), available in the Cahnos catalogue with and without introducer. Verify the integrity of the sterile packaging before each use and dispose of the needle after a single puncture in an approved container for sharps and cutting waste. For volume orders, supply contracts or tenders, contact the technical-commercial team at Cahnos.

Additional information

Brand

B. Braun

Application

Spinal anaesthesia and diagnostic lumbar puncture

Stylet material

stainless steel

Connector design

square

Packaging

Individual blister

Sterility

Sterile (EO), single-use

Sterilisation

EO

Presentation

Box of 25 units

Calibre (G)

18, 26, 25, 22, 29, 27, 20

Longitud

88 mm, 120 mm, 75 mm, 40 mm

Con introductor

No, Sí

Referencia

4501390N-01, 4502906N-01, 4505905N-01, 4505913N-01, 4507908N-01, 4501900N-01, 4502140N-01, 4503902N-01, 4505751N-01, 4506090N-01, 4507401N-01, 4507754N-01, 4509900N-01, 4504917N-01, 4509757N-01, 4521801N, 4522001N, 4522201N, 4522203N, 4522701N, 4522204N, 4522501N, 4522601N, 4522702N, 4522202N

Product line

Spinocan®

Product type

Spinal needle

Bevel type

Quincke (cutting)

Available sizes

22G to 29G

Connection

NRFit® (ISO 80369-6)

Material

Medical-grade stainless steel cannula; stainless steel stylet

Hub

Transparent with prism that reflects CSF outflow

Mandrel

Colour-coded

Contains PVC

No

Contains DEHP

No

Latex

Latex-free

Tipo uso

Single-use

Documentation

Reviews

There are no reviews yet.

Be the first to review “Spinocan® NRFit® Spinal Needle B. Braun – Quincke Bevel 22G–29G with NRFit® Connection (ISO 80369-6) for Spinal Anaesthesia and Lumbar Puncture”

Your email address will not be published. Required fields are marked *