Description
1. Introduction
The Pencan® NRFit® range from B. Braun is the reference in anaesthesiology and operating theatre services when seeking safe, controlled and minimally traumatic access to the subarachnoid space. These atraumatic pencil-point needles (Whitacre type) are indicated for spinal/subarachnoid anaesthesia, lumbar subarachnoid anaesthesia and diagnostic lumbar puncture, with particular value in patients where the aim is to minimise the risk of post-dural puncture headache (PDPH).
The family covers gauges from 22G to 27G and lengths ranging from 50 mm (paediatrics) to 156 mm (extra-long), in versions with and without introducer, all with the NRFit® connection (ISO 80369-6) that guarantees exclusive compatibility with the regional anaesthesia system and prevents accidental connection with Luer taper devices.
2. Technical explanation of the procedure
Spinal or subarachnoid anaesthesia consists of administering local anaesthetic into the cerebrospinal fluid (CSF) of the subarachnoid space, achieving a rapid, deep and reliable sensory and motor block, suitable for abdominal, urological, trauma, obstetric and lower limb surgery.
Unlike cutting bevel needles of the Quincke type, the pencil point of the Pencan® separates the dural fibres rather than cutting them, which promotes spontaneous sealing of the dura and significantly reduces the incidence of post-puncture headache, neurological injury and subsequent lower back pain. The transparent hub with prism shines silver before reflux and becomes transparent when CSF passes through, immediately confirming correct cannulation before injection. The obturator stylet with colour-coded mandrel ensures lumen patency and precise orientation throughout the puncture.
The NRFit® connection (ISO 80369-6) is the differentiating attribute of this range: it is specifically designed for intrathecal and regional anaesthesia devices, eliminating the risk of incorrect connections with stopcocks and Luer taper administration systems, in line with international safety recommendations for neuraxial procedures.
3. Technical Specifications
| Characteristic | Specification |
| Brand / Line | B. Braun – Pencan® NRFit® |
| Available sizes | 22G (0.70–0.73 mm), 25G (0.50–0.53 mm), 27G (0.40–0.42 mm) |
| Available lengths | 50 mm (2″), 88 mm (3 1/2″), 103 mm (4″), 120 mm (4 3/4″), 156 mm |
| Tip type | Atraumatic pencil point (Whitacre type) |
| Connection | NRFit® (ISO 80369-6) |
| Introducer | With or without introducer depending on reference |
| Material | Cannula of medical-grade stainless steel; stainless steel stylet; transparent hub with prism |
| Application | Spinal / rachidian / subarachnoid anaesthesia and diagnostic lumbar puncture |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Packaging | Individual sterile blister |
| Presentation | Box of 25 units |
| Latex-free / PVC / DEHP | Yes (does not contain latex, PVC or DEHP) |
| Storage | 10 °C – 25 °C; humidity 30 % – 90 % |
Pencan® reference range (official standard B. Braun):
| Gauge | Length | Introducer | Packaging | Ref. standard B. Braun |
| 27G | 88 mm (3 1/2″) | No | 25 units | 254502027-01 |
| 27G | 88 mm (3 1/2″) | Yes | 25 units | 254502051-13 |
| 27G | 103 mm (4″) | Yes | 25 units | 254502124-13 |
| 27G | 120 mm (4 3/4″) | No | 25 units | 254502132-13 |
| 27G | 50 mm (2″) – paediatrics | No | 25 units | 4502175-13 |
| 25G | 88 mm (3 1/2″) | No | 25 units | 254502019-01 |
| 25G | 88 mm (3 1/2″) | Yes | 25 units | 254502043-13 |
| 25G | 103 mm (4″) | Yes | 25 units | 254502116-13 |
| 25G | 120 mm (4 3/4″) | No | 25 units | 254502120-13 |
| 25G | 50 mm (2″) – paediatrics | Yes | 25 units | 254502159-13 |
| 25G | 156 mm – extra-long | No | 25 units | 333877 |
| 22G | 88 mm (3 1/2″) | Yes | 25 units | 254502035-13 |
Note: the references cited correspond to the official standard of the Pencan® range; the exact configuration with NRFit® connection (ISO 80369-6) is supplied under the same family and the NRFit® catalogue reference must be confirmed with the technical-commercial department of Cahnos when placing the order.
4. Equivalences and Cross-References
B. Braun does not publish an official cross-reference table for the Pencan® NRFit® range; equivalences between brands must be verified field by field before use in tenders. By tip family (atraumatic pencil point with NRFit connection, ISO 80369-6), the following references from other manufacturers are comparable by category (not interchangeable 1:1):
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| BD | Whitacre Pencil Point Spinal 27G × 3 1/2″ (0.40 × 90 mm) with 22G introducer, NRFit connection (ISO 80369-6) | 405075 | Comparable by category (not interchangeable 1:1) | Same atraumatic pencil-point family, 27G gauge and NRFit connection; slightly longer length (90 mm vs 88 mm) and includes introducer |
| BD | Whitacre Pencil Point Spinal NRFit 22G × 3 1/2″ (0.70 × 90 mm), NRFit connection (ISO 80369-6) | 401995 | Comparable by category (not interchangeable 1:1) | Same atraumatic pencil-point family and NRFit connection; 22G gauge and 90 mm length compared to the 88 mm version |
| Dahlhausen | Spinal needle with pencil point 27G × 3.5″ / 89 mm with introducer | 76.222.27.035 | Comparable by category (not interchangeable 1:1) | Same atraumatic tip family and 27G gauge with introducer; Luer-Lock connection (not NRFit, ISO 80369-6) |
Technical warnings: the pencil point (Pencan, Whitacre, Sprotte) is not equivalent to the cutting Quincke-type point (e.g., Spinocan® from B. Braun or BD’s Quincke line): the incidence of post-puncture headache is different and they should not be substituted for each other without clinical evaluation. Other brands with a homologous pencil-point family with NRFit connection (Vygon Whitacre NRFit™, Pajunk Sprotte) are comparable by category; their specific codes are pending confirmation with each manufacturer before citing them. Always verify before substitution: gauge, length, tip type, presence of introducer, connector (Luer vs NRFit, ISO 80369-6) and sterility of the actual product. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Gauge: prioritise 27G for minimal dural trauma and lower incidence of post-dural puncture headache; 25G offers the best balance between trauma and injection flow rate; 22G provides maximum flow rate and rigidity for techniques requiring rapid confirmation of CSF flow.
- Length: 88 mm (3 1/2″) is the standard for adults of medium build; 103 mm and 120 mm for patients with a longer insertion path or adipose panniculus; 156 mm extra-long for deep tissue planes.
- Paediatrics: 50 mm (2″) versions in 25G and 27G gauges for paediatric patients and very thin build.
- Introducer: versions with a guide protect the fine cannula during advancement through tissues and improve tactile control; in the current design they provide an additional 10 mm of useful length.
- NRFit® connection: choose this range if your installed base of regional anaesthesia devices is NRFit (ISO 80369-6) or if your protocol requires prevention of misconnections with Luer systems.
Check the integrity of the sterile packaging before each use and dispose of the needle after a single puncture in an approved container for sharps and cutting waste. For volume orders, supply contracts or tenders, contact the technical-commercial team at Cahnos.