Paediatric laryngoscope set MAXLITE F.O. fibre-optic – 3 Miller blades 00-0-1, rechargeable xenon/halogen handle 2.5 V · 8,000 lux (Ref. 34332)

285,00 €

Paediatric laryngoscope set MAXLITE F.O. fibre-optic with 3 straight Miller blades (sizes 00-0-1) and 2.5 V rechargeable xenon/halogen handle providing cold, bright illumination of up to 8,000 lux. Blades with integrated fibre optics, non-magnetic and reusable, from the GREEN family, compatible with standard Green handles according to BS EN ISO 7376 and autoclavable up to 134 °C. Ideal for intubation of neonates, infants and children in anaesthesia, paediatrics, neonatology, emergency and critical care. Battery and charging base 31542 not included. Class I medical device. For large orders, you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM34332

Description

1. Commercial Introduction

The MAXLITE F.O. paediatric laryngoscope set is the reference equipment for direct laryngoscopy and orotracheal intubation of neonates, infants and children. It includes three Miller straight-profile blades in sizes 00, 0 and 1, with fibre optics integrated into the blade body itself, and a 2.5 V rechargeable handle with xenon/halogen bulb capable of providing cold, bright illumination of up to 8,000 lux, ensuring a clear view of the glottis even in small and delicate anatomies.

It belongs to the renowned GREEN series of laryngoscopes, characterised by its robustness, maximum light transmission and compatibility with the Green standard most widespread in the European market. It is the ideal choice for anaesthesiology, paediatrics, neonatology, emergency, critical care and resuscitation departments.

2. Technical explanation of the equipment and procedure

Direct laryngoscopy is the reference technique for endotracheal intubation. In the paediatric population, the straight Miller blade is the geometry of choice: it allows direct elevation of the epiglottis to expose the glottis, being especially useful in infants and young children, where airway management requires maximum precision and the least possible leverage force. Sizes 00, 0 and 1 cover from premature and newborn infants up to older children.

The MAXLITE blades incorporate fibre optics integrated into the blade body itself, eliminating the central light point and offering a wider, more homogeneous field of view. The light travels from the xenon/halogen bulb of the 2.5 V rechargeable handle to the distal end of the blade, providing intense, stable illumination of up to 8,000 lux without heat generation on the tissues. The blades are non-magnetic, an important requirement in environments with equipment sensitive to magnetic fields.

3. Technical Specifications

Reusable paediatric laryngoscopy set from the MAXLITE / GREEN series with integrated fibre optic illumination and xenon/halogen bulb.

  • F.O. laryngoscopes with cold, bright illumination (cool bright illumination) of up to 8,000 lux.
  • Paediatric set with 3 Miller blades with integrated fibre optics (sizes 00-0-1).
  • MAXLITE blades with integrated fibre optics and anti-glare matte finish.
  • Rechargeable F.O. handle with xenon/halogen bulb.
  • 2.5 V rechargeable handle (battery not included); accepts standard or rechargeable batteries. Rechargeable handles must be used with charging base 31542 (not included).
  • Non-magnetic blades, manufactured in corrosion-resistant austenitic stainless steel.
  • Blades autoclavable up to 134 °C for 5 minutes (up to 2,000 cycles) and compatible with plasma sterilisation.
  • Compatibility with standard Green handles according to BS EN ISO 7376.
  • 3-year manufacturer’s warranty.
Reference Model Sales unit Details
GM34332 3 Miller blades 00-0-1 1 pc Paediatric set (3 Miller blades 00-0-1) · 2.5 V · 8,000 lux

Product data

Brand MAXLITE
Manufacturer GIMA
Manufacturer reference 34332
Lighting Fibre optic, xenon/halogen bulb · 8,000 lux
Handle voltage 2.5 V (rechargeable, battery not included)
Blade profile Miller (straight) 00-0-1 – integrated fibre optic
Sales unit 1 pc
Device type Medical device (Medical device)
Device class I
CND Z12021003
GMDN 15076
EAN 8023279343328

4. Equivalences and Cross-References

This set belongs to the international Green System standard (BS EN ISO 7376), so its blades are interchangeable at the connection level with reusable laryngoscope handles that comply with this same standard, regardless of their light source (AA or C batteries, 2.5 V and 3.5 V rechargeable batteries, xenon/halogen or LED bulbs).

Within the catalogue itself, the counterpart of this paediatric configuration with LED illumination is the MAXLITE F.O. LED PEDIATRIC set (ref. GM34336, 3 Miller blades 00-0-1, 20,000 lux), which shares the same blade family. The equivalent from the GREEN family with detachable fibre is the paediatric set GM34451/GM34454 (Miller blades 0-1 and McIntosh 0). The adult sets of the same MAXLITE series are refs. GM34333/GM34334 (xenon/halogen, 8,000 lux) and GM34335/GM34337 (LED, 20,000 lux). Individual blades from the MAXLITE line are available in Miller sizes (refs. 58051 and 58052) and McIntosh sizes (refs. 58056 to 58061). As recharge accessories, the 2.5 V rechargeable battery (ref. 34467) and the charging base 31542 (not included) are recommended.

No 1:1 equivalence table validated by the manufacturer against third-party codes (e.g. Heine, Penlon, Riester or KaWe) is available; before replacing blades from another brand, the fit of the connection, profile and size must be verified according to BS EN ISO 7376 and the reference checked with the technical department of Cahnos.

5. Selection tips and variants of interest

Choose the blade size according to the patient: size 00 corresponds to premature infants, size 0 to newborns and small infants, and size 1 to infants and young children. This set covers the entire initial paediatric spectrum, making it ideal as the main equipment for a paediatric airway trolley or a neonatology unit.

The 2.5 V handle accepts standard or rechargeable batteries (not included); for intensive use, it is recommended to have the charging base 31542 (not included) and spare batteries. Follow the indicated reprocessing protocol (autoclave at a maximum of 134 °C for 5 minutes, with a limit of 2,000 cycles) and always remove the battery from the handle before cleaning or sterilisation to prolong the instrument’s service life and maintain the warranty. For complete equipment, airway trolleys or tenders, contact the technical-commercial department of Cahnos:. For large orders you can request a quote.

Additional information

Original manufacturer

GIMA S.p.A.

Manufacturer reference

34332

Product type

Reusable paediatric laryngoscope set

Blade profile

Miller (straight), sizes 00-0-1

Population

Neonates, infants and children

Illumination system

Fibre optic (F.O.) with integrated fibre and xenon/halogen bulb

Light output

8,000 lux

Handle voltage

2.5 V (rechargeable, battery not included)

Power supply

Standard or rechargeable batteries (not included); charging base 31542 (not included)

Blade material

Corrosion-resistant austenitic stainless steel

Finish

Anti-glare matte finish

Magnetism

Non-magnetic

Sterilisation

Autoclave up to 134 °C / 5 min; up to 2,000 cycles; compatible with plasma sterilisation

Compatibility

Standard handles Green System BS EN ISO 7376

Warranty

3 years

Device type

Medical device (Medical device)

CND code

Z12021003

GMDN code

15076

EAN

8023279343328

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEspañol PDF · English PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Paediatric laryngoscope set MAXLITE F.O. fibre-optic – 3 Miller blades 00-0-1, rechargeable xenon/halogen handle 2.5 V · 8,000 lux (Ref. 34332)”

Your email address will not be published. Required fields are marked *