Description
1. Introduction
The oral reinforced tracheal endotracheal tube with cuff, guide and Murphy eye ID 6.5 mm (ref. ETAM65C02A1) is the airway solution that anaesthesia, emergency and intensive care services need when face mask ventilation is not viable. Its helical reinforcement makes it the reference option when tube movement, special positioning or head and neck surgery are anticipated. It is presented in a box of 10 units, ready for restocking intubation trolleys, ICU bays and operating theatres, with a uniform and reliable standard in every procedure.
2. Technical explanation of the device
In orotracheal intubation, the tube is introduced orally through the glottis until its distal end is positioned in the trachea, below the vocal cords. The included insertion guide provides controlled rigidity during advancement and allows correct positioning, being removed once the tube is placed. The reinforced body (helical spiral integrated into the PVC wall) prevents tube collapse under external compression, biting or kinking. The cuff, inflated via the pilot balloon with Luer connection, seals the tracheal lumen and allows positive pressure ventilation without leaks, as well as preventing aspiration of secretions. The Murphy eye, a distal lateral orifice, acts as a safety route: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through this orifice, avoiding total occlusion. It connects to the ventilator, anaesthesia circuit or resuscitation bag via the universal 15 mm connector in accordance with ISO 5356-1.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
| Reference | ETAM65C02A1 |
| Type | Reinforced oral endotracheal tube with cuff |
| Internal diameter (ID) | 6.5 mm |
| Access route | Oral (orotracheal) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent |
| Reinforcement | Integrated helical spiral, kink resistance |
| Insertion guide | Yes, included |
| Sleeve | Cuffed, inflated via pilot balloon with Luer connection |
| Murphy eye | Present (distal lateral safety opening) |
| Connector | Universal 15 mm (ISO 5356-1) |
| Radiopacity | X-ray contrast line |
| Latex | Natural rubber latex-free |
| Sterility | Sterile, individually packaged (ethylene oxide) |
| Use | Single-use, non-reusable |
| Indications | Positive pressure ventilation and anaesthesia administration |
| Presentation | Box of 10 units |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the manufacturer’s declaration of conformity and CE marking on each supplied batch before use in procedures.
Range of sizes available from Cahnos (ETAM family, reinforced with cuff and guide):
| Reference | Internal diameter (ID) | Indicative patient |
| ETAM30C02A1 | 3.0 mm | Newborn |
| ETAM35C02A1 | 3.5 mm | Newborn |
| ETAM45C02A1 | 4.5 mm | Child |
| ETAM50C02A1 | 5.0 mm | Child |
| ETAM55C02A1 | 5.5 mm | Child / small adult |
| ETAM65C02A1 (this product) | 6.5 mm | Small adult |
| ETAM70C02A1 | 7.0 mm | Adult |
| ETAM75C02A1 | 7.5 mm | Adult |
| ETAM80C02A1 | 8.0 mm | Adult |
| ETAM85C02A1 | 8.5 mm | Adult / large adult |
| ETAM90C02A1 | 9.0 mm | Large adult |
| ETAM95C02A1 | 9.5 mm | Large adult |
4. Equivalences and Cross-References
Functional category equivalence (not interchangeable 1:1). By clinical indication (oral reinforced endotracheal tube with cuff and Murphy eye, ID 6.5 mm) this product is comparable to reinforced tubes from manufacturers such as Teleflex (Rüsch® / Sheridan®), Medtronic (Shiley™ / Mallinckrodt™), ICU Medical (Portex® Blue Line®) and Intersurgical. All these brands offer oral tubes with helical reinforcement to resist compression, but they differ in outer diameter (OD), total length, distal end geometry and cuff characteristics, so they must be compared specification by specification before replacing a specific product. On the market, third-party references can be found such as the Rüschflex® 6.5 from Teleflex or the Safety-Flex 118-65M line of 6.5 mm: they are cited solely as a functional category comparison and their code must be verified against the manufacturer before any replacement.
The reference ETAM65C02A1 is a proprietary code of the Cahnos range; it does not correspond to an official manufacturer part number published in public sources, so it must be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before use in tenders or stock replacement.
Comparable by category within the Cahnos catalogue in the same ID 6.5 mm size (not interchangeable 1:1):
| Reference | Description |
| ETA065C02A2 | Oral reinforced endotracheal tube with cuff, without guide |
| ETAN65C02 | Oral endotracheal tube with cuff and Murphy eye, without reinforcement |
| ETSL65C02 | Oral endotracheal tube with cuff and subglottic suction lumen |
| ETPN65C02 | Preformed nasal tracheal tube with cuff and Murphy eye |
5. Selection tips and variants of interest
- The ID 6.5 mm is intended for adolescent or small-framed adult patients; as a general guide, in adults tubes of 7.0 to 9.0 mm are used depending on build, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
- Verify the integrity of the cuff and pilot balloon before insertion and control the sealing pressure with a manometer, keeping it within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm the service protocol).
- The reinforced tube with guide is especially indicated when frequent repositioning, prone positioning, head and neck surgery or risk of kinking are anticipated.
- If intubation is to be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL65C02); if a guide is not required, the standard reinforced ETA065C02A2 can be selected; for nasal approaches, the preformed ETPN65C02.
- For volume conditions, samples or hospital supply lead times, contact the technical and commercial department of Cahnos.





Reviews
There are no reviews yet.