Description
1. Commercial Introduction
The Miller No. 1 laryngoscope blade for infant patients (ref. 34312) is the classic and reliable solution for direct laryngoscopy and orotracheal intubation in babies and infants. It is part of the renowned range of laryngoscopes, characterised by the quality of its materials, the durability of its stainless steel contacts and the excellent light transmission of its 2.5 V vacuum bulbs.
It is the professional choice for anaesthesiology, paediatrics, emergency, critical care and resuscitation departments seeking reusable, ergonomic instruments compatible with the most widespread standard Green handles on the European market. For large orders you can request a quote: ask for terms and availability from our technical-commercial team.
2. Technical explanation of the equipment and procedure
Direct laryngoscopy with a Miller-type blade is the classic straight-profile technique for endotracheal intubation: the straight blade directly lifts the epiglottis, exposing the glottis and facilitating the passage of the endotracheal tube. Size No. 1 is specifically designed for the infant anatomy (babies), where an inadequate blade would compromise visualisation and increase the risk of injury.
This blade incorporates a standard 2.5 V vacuum bulb which, combined with the stainless steel contacts, guarantees a light transmission of up to 3,500 LUX and a long service life. The coupling according to standard ISO 7376 allows its use with existing handles from the same range or from other manufacturers that comply with the Green standard, while the satin finish of the associated handles reduces reflections during examination. The blade is non-magnetic and latex-free.
3. Technical Specifications
Reusable laryngoscope blade from the range, straight profile Miller No. 1, indicated for infant patients (babies), with standard 2.5 V vacuum bulb and coupling ISO 7376.
| Characteristic | Specification |
|---|---|
| Manufacturer reference (SKU) | 34312 (SKU GM34312) |
| Blade model | Miller (MILLER) No. 1 |
| Target population | Infants / babies (babies) |
| Total length (Overall Length) | 102 mm |
| Distal width (Distal Width) | 11.5 mm |
| Lighting | Standard vacuum bulb 2.5 V |
| Light transmission (with 2.5 V handles) | 3,500 LUX |
| Compatibility | Coupling ISO 7376; compatible with standard Green handles |
| Contacts | Stainless steel (long service life) |
| Sterilisation | Autoclavable up to 134 °C for 5 minutes (approx. 2,000 cycles); also ETO or steam |
| Other features | Non-magnetic blade; latex-free |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | Z12021099 |
| GMDN | 46827 |
| EAN | 8023279343120 |
Advantages certified by the manufacturer
- Standard 2.5 V vacuum bulb.
- Lightweight ergonomic handle with a satin finish that reduces reflections.
- Stainless steel contacts that ensure a long service life.
- Easy sterilisation by ETO or steam.
- Complete range of Mc-Intosh and Miller blades, latex-free.
- Couplings ISO 7376 that allow use with existing handles.
- The 2.5 V handles work with alkaline batteries or rechargeable batteries.
- Good light transmission: 3,500 LUX with 2.5 V handles.
- Autoclavable up to 134 °C for 5 minutes (approx. 2,000 times).
- Non-magnetic blades.
4. Equivalences and Cross-References
This blade belongs to the international Green System coupling standard (ISO 7376 / BS EN ISO 7376), therefore it is interchangeable at the connection level with reusable laryngoscope handles that comply with this same standard, regardless of their light source (batteries, rechargeable batteries of 2.5 V and 3.5 V, or xenon/halogen or LED bulbs).
Within the catalogue itself, the homologous blade by profile, size and population within the GREEN F.O. fibre optic series is the Miller No. 1 for infants (ref. 34462 / SKU GM34462). Similar references from the same classic range include the Miller No. 2 blade for adults (ref. 34313 / GM34313) and the Mc-Intosh No. 1 blade for infants (ref. 34318 / GM34318); the HEINE Classic+ F.O. Miller 1 blade (ref. GM34413, 100 mm / 11.5 mm) offers a straight profile with very close geometry within the same standard. There is no 1:1 equivalence table validated by the manufacturer against third-party codes (e.g. Penlon, Riester or KaWe); before replacing a blade from another brand, the fit of the connection, the profile and the size must be verified according to ISO 7376 and the reference checked with the technical department of Cahnos.
5. Selection tips and variants of interest
The blade size must be chosen according to the patient’s age and anatomy: in the classic Miller series (refs. 34310 to 34314), size No. 1 (this reference) is indicated for infants and babies, while the smaller sizes cover neonatal/premature population and size No. 2 (ref. 34313) is aimed at adult patients with reduced anatomy. For curved profiles in the paediatric population, the Mc-Intosh family (refs. 34317 to 34321) constitutes the complementary classic alternative.
To complete the laryngoscope, combine this blade with a standard Green handle (ISO 7376) from the range: the 2.5 V handles accept standard alkaline batteries or rechargeable batteries and offer up to 3,500 LUX of light transmission. Always verify the fit compatibility before each procedure and follow the recommended sterilisation protocol (autoclave at a maximum of 134 °C for 5 minutes, with an approximate limit of 2,000 cycles) to prolong the service life of the instrument. For complete sets, airway trolleys or tenders, contact the technical-commercial department of Cahnos:.