Reinforced Oral Endotracheal Tube with Cuff, Stylet and Murphy Eye – ID 5.5 mm | Medical-Grade PVC, Sterile, Box of 10 units (Ref. ETAM55C02A1)

118,95 €

Reinforced oral endotracheal tube with cuff, stylet and Murphy eye, internal diameter 5.5 mm (ref. ETAM55C02A1), manufactured from medical-grade polyvinyl chloride, transparent, latex-free and single-use. Its integrated helical spiral resists kinking and external compression, keeping the airway patent during positive-pressure ventilation and administration of anaesthesia when a face mask is not viable. Includes intubation stylet, cuff with pilot balloon and self-sealing valve, universal 15 mm connector (ISO 5356-1), radiopaque line and depth scale. Presentation: box of 10 units sterile, ideal for the intubation trolley, operating theatre and critical care units. Verify the CE/MDR marking of each batch before use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAM55C02A1

Description

1. Introduction

The 5.5 mm oral reinforced endotracheal tube with cuff, stylet and Murphy eye (ref. ETAM55C02A1) is the airway solution that anaesthesia, emergency and intensive care services need when mask ventilation is not feasible. Made from medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the resistance of the anti-kink helical reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, offering a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, ready for restocking intubation trolleys, ICU bays and operating theatres with a uniform and reliable standard.

2. Technical explanation of the device and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision aided by the included intubation stylet, passes through the glottis and sits in the trachea, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The stylet provides controlled rigidity during advancement and is removed once the tube is placed. The helical reinforcement embedded in the PVC wall prevents kinking and collapse during flexion, head and neck movements, biting or external compression, making it especially suitable for ENT, maxillofacial, thyroid surgeries or complex surgical positions. The cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety pathway: if the tip becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through that opening and occlusion is never total. The radiopaque line and depth scale allow radiographic verification of correct position. It is a single-use device: it must be discarded after each patient to prevent cross-infection.

3. Technical Specifications

The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference (SKU) ETAM55C02A1 (distributor’s own code Cahnos)
Type Reinforced oral tracheal endotracheal tube (orotracheal), with cuff, stylet and Murphy eye
Access route Oral (orotracheal)
Internal diameter (ID) 5.5 mm (approximate calibre of 22 Fr according to common market usage, indicative)
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Reinforcement Integrated helical spiral, kink resistance
Sleeve Sealed, with pilot balloon and self-sealing valve
Intubation guide Included (insertion guide/stylet, removed after placement)
Murphy eye Present (distal lateral safety opening)
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth scale
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, non-reusable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; the connector complies with the corresponding part of standard ISO 5356-1. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.

Range of sizes available at Cahnos (ETAM family, reinforced with cuff, guide and Murphy eye):

Reference Internal diameter (ID) Indicative patient
ETAM30C02A1 3.0 mm Newborn
ETAM35C02A1 3.5 mm Newborn
ETAM45C02A1 4.5 mm Child
ETAM50C02A1 5.0 mm Child
ETAM55C02A1 (this product) 5.5 mm Older child / small adult
ETAM65C02A1 6.5 mm Small adult
ETAM70C02A1 7.0 mm Adult
ETAM75C02A1 7.5 mm Adult
ETAM80C02A1 8.0 mm Adult
ETAM85C02A1 8.5 mm Adult / large adult
ETAM90C02A1 9.0 mm Large adult
ETAM95C02A1 9.5 mm Large adult

4. Equivalences and Cross-References

The SKU ETAM55C02A1 is a proprietary code of Cahnos (ETAM series: oral reinforced tracheal tubes with cuff and stylet) and does not correspond to the official part number of any specific manufacturer published in public sources. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in specifications, tenders or direct replacement of stock from another brand.

The following options are classified as comparable at category level (not 1:1 interchangeable), pending technical verification against the official datasheet of each manufacturer (they differ in outer diameter, total length, distal tip geometry and cuff characteristics):

Reference / Line Description Degree of correspondence
ETA055C02A2 (Cahnos) Reinforced oral tube with cuff and Murphy eye, ID 5.5 mm, without stylet Comparable by category; differs in the included guide
ETAN55C02 (Cahnos) Oral tube with cuff and Murphy eye, ID 5.5 mm, without reinforcement Comparable by category; without helical reinforcement
849055-M (ENDOSID®, Asid Bonz) Spiral reinforced endotracheal tube with stylet and Murphy eye, 5.5 mm Comparable by category; pending verification of official data sheet
44.000.20.055 (P. J. Dahlhausen) Reinforced endotracheal tube with cuff, 5.5 mm Comparable by category; same size and reinforcement, verify design and IFU
44.000.10.055 (P. J. Dahlhausen) Magill-type endotracheal tube with cuff and Murphy eye, 5.5 mm Comparable by category; without spiral reinforcement
Rüsch® / Sheridan® (Teleflex) Line of reinforced tubes with cuff (stainless steel spiral reinforcement) Comparable by category; not interchangeable 1:1 without datasheet verification

Fields verified before comparing: internal diameter (5.5 mm), material (PVC), cuff type, presence of stylet, Murphy eye, 15 mm connector and helical reinforcement. Any difference in one of these fields places the comparison at category level, not exact equivalence.

5. Selection tips and variants of interest

  • Size selection (usual use in clinical practice, not manufacturer specification): the 5.5 mm ID is intended for older paediatric patients, adolescents or adults with a reduced airway calibre. The final choice must be based on the service protocol and anaesthetic assessment (age, weight and estimated airway calibre), always selecting the largest size compatible with the patient’s anatomy.
  • Cuff pressure: check the integrity of the cuff and pilot balloon before insertion; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) monitoring with a manometer if the service has one, to minimise pressure injury on the tracheal mucosa.
  • Pre-verification: check the correct fixation and removal of the stylet after placement, the patency of the Murphy eye, the inflation of the cuff and the secure attachment of the 15 mm connector to the circuit.
  • Variants of the same size (ID 5.5 mm): reinforced with cuff without stylet (ETA055C02A2), with cuff without reinforcement (ETAN55C02), oral preformed (ETPO55C02) or nasal preformed (ETPN55C02). For prolonged intubations with risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL series).
  • Other sizes in the ETAM family: the series covers from 3.0 mm to 9.5 mm (ETAM30C02A1 to ETAM95C02A1), allowing the intubation trolley to be completed with a single supplier.

For volume conditions, samples or hospital supply lead times, contact the technical-commercial department of Cahnos for the approval of references and configuration of the most suitable size stock for your service.

Additional information

Product type

Reinforced oral endotracheal tube with cuff, guide and Murphy eye

Access route

Oral (orotracheal)

Inner diameter

5.5 mm

Approx. calibre Fr

22 Fr (indicative, common market usage)

Material

Medical-grade polyvinyl chloride (PVC), transparent, latex-free

Reinforcement

Integrated helical spiral, anti-kink

Sleeve

Sealed, with pilot balloon and self-sealing valve

Intubation guide

Included (removed after placement)

Murphy eye

Present (distal lateral safety opening)

Connector

Universal 15 mm (ISO 5356-1)

Radiopacity

Radiopaque line and depth scale

Sterilisation

Ethylene oxide (EO), sterile, individual packaging

Use

Single-use, non-reusable

Regulatory standard

ISO 5361 (tracheal tubes and connectors); connector ISO 5356-1

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Presentation

Box of 10 units

Unit of sale

Box (10 units)

Reviews

There are no reviews yet.

Be the first to review “Reinforced Oral Endotracheal Tube with Cuff, Stylet and Murphy Eye – ID 5.5 mm | Medical-Grade PVC, Sterile, Box of 10 units (Ref. ETAM55C02A1)”

Your email address will not be published. Required fields are marked *