Description
Introduction
The Guedel airway ISO10 10 cm (ref. 830040M) is an essential medical device for basic and advanced airway management in unconscious patients or those with a reduced level of consciousness. Designed to separate the tongue from the posterior pharyngeal wall, it facilitates ventilation with a self-inflating bag, oxygenation and suction of secretions in critical situations.
What it is and how it works
The Guedel oropharyngeal airway is manufactured in rigid medical plastic with an anatomical curve that reproduces the morphology of the palate and pharynx. Its central channel and lateral reinforcements prevent the tongue and soft tissues from collapsing over the hypopharynx during ventilation, maintaining a continuous airflow. It is commonly used in anaesthetic induction, cardiopulmonary resuscitation and prehospital care, always as a complement to adequate airway opening and assisted ventilation. Size ISO10, with a length of 10 cm, is indicated for adult patients of medium-tall height.
Technical specifications
| Parameter | Specification |
| Reference | 830040M |
| Model / Size | ISO10 |
| Length | 10 cm |
| Material | Rigid, durable and anatomical medical plastic |
| Use | Maintenance of oropharyngeal airway patency |
| Application | Anaesthesia, resuscitation and medical emergencies |
| Function | Prevents tongue obstruction and ensures airflow |
| Indication | Adult patients (medium-tall height) |
| Presentation | Unit |
Equivalences and cross-references
This airway is part of the Cahnos range of Guedel airways in progressive sizes: ISO10 (ref. 830040M, 10 cm), ISO11 (ref. 830050M, 11 cm) and ISO12 (ref. 830060M, 12 cm), allowing different adult patient profiles to be covered within the same technical family. As complementary alternatives, Cahnos offers the Guedel Soft Airway ISO10 (ref. SGU241100) in flexible material for sensitive anatomies, the Guedel Optical Fibre Airway ISO10 (ref. SLT253100) for intubation in low-visibility conditions, and sterile oropharyngeal airways for clinical use in sizes from 6 to 11 cm (refs. 5000 to 5005), ideal for completing the intubation trolley and comprehensive airway management in anaesthesia, emergency and critical care services.
Selection tips and variants
To choose the correct Guedel airway size, measure the distance between the labial commissure and the mandibular angle of the patient. As a reference, size ISO10 (10 cm) fits adult patients of medium-tall height; patients of smaller stature may require ISO9 or ISO8, and larger patients, ISO11 or ISO12. For paediatric patients or those with delicate oral tissues, the Soft version is recommended, while in difficult intubation or low-light situations, the optical fibre version provides a differential advantage. Consult our technical-commercial team to assess volumes, supply conditions and the configuration of airway kits adapted to your anaesthesia, emergency, ICU or medical transport service.




Reviews
There are no reviews yet.