Description
1. Product Presentation
The oral reinforced uncuffed endotracheal tube with Murphy eye of 10.0 mm (Ref. ETA010002A2) is the airway solution that your anaesthesia, intensive care and emergency department needs when face mask ventilation is not viable and the largest size in the family is required for large adult patients. Manufactured from medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the anti-kink helical reinforcement with the safety of the Murphy eye and a cuffless design that reduces the risk of pressure injury to the tracheal mucosa. Supplied in a box of 10 individually packaged units, it is the ideal format for restocking the intubation trolley, the operating theatre and critical care units.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs through the universal 15 mm connector.
The helical spiral integrated into the PVC wall resists compression, biting and kinking, maintaining airway patency even with head movement, cervical flexion-extension or postural changes, situations frequent in neurosurgery, head and neck surgery and prone position ventilation. As it has no cuff, sealing is achieved by the fit of the size against the tracheal wall, so correct size selection is crucial. The Murphy eye, a lateral opening located near the distal tip, acts as a backup ventilation pathway: if the main lumen were obstructed by secretions or kinking, airflow continues through this opening and occlusion is never total. The radiopaque line and depth graduation allow radiographic verification of the tube position.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Reference (SKU) | ETA010002A2 (Cahnos distributor’s own code; ETA series: reinforced cuffless) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 10.0 mm (maximum size in the range; large-framed adult) |
| Configuration | Reinforced, cuffless (sealed by size fit) |
| Reinforcement | Anti-kink helical spiral integrated into the tube wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Cuffless (facilitates insertion and reduces the risk of pressure injury) |
| Murphy eye | Present, distal lateral safety orifice |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, non-reusable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Indicative population | Large adult (largest size in the range) |
| Presentation | Box of 10 individually packaged units |
| Regulatory standard | ISO 5361 (tracheal tubes and connectors); connector according to ISO 5356-1; verify CE/MDR marking of each batch |
This size belongs to the Cahnos range of oral reinforced uncuffed endotracheal tubes with Murphy eye (ETA series), available in several diameters to complete the department’s stock:
| Reference | Internal diameter (ID) |
| ETA030002A2 | 3.0 mm |
| ETA035002A2 | 3.5 mm |
| ETA040002A2 | 4.0 mm |
| ETA045002A2 | 4.5 mm |
| ETA050002A2 | 5.0 mm |
| ETA055002A2 | 5.5 mm |
| ETA060002A2 | 6.0 mm |
| ETA065002A2 | 6.5 mm |
| ETA070002A2 | 7.0 mm |
| ETA075002A2 | 7.5 mm |
| ETA080002A2 | 8.0 mm |
| ETA085002A2 | 8.5 mm |
| ETA090002A2 | 9.0 mm |
| ETA095002A2 | 9.5 mm |
| ETA010002A2 (this product) | 10.0 mm |
4. Equivalences and Cross-References
Reference ETA010002A2 is a proprietary code from the Cahnos catalogue (ETA series: oral reinforced uncuffed tracheal tubes) and must not be confused with the official part number of any specific manufacturer. For this configuration (oral, reinforced, uncuffed, with Murphy eye, ID 10.0 mm) there is no manufacturer-validated equivalence table in the official sources consulted; the following references are offered exclusively as a functional category comparison, not interchangeable 1:1, and must be confirmed with the Cahnos technical department before use in tenders or stock replacement:
| Manufacturer / Line | Reference | Description | Degree of correspondence |
| P. J. Dahlhausen (Woodbridge series) | 44.000.20.100 | Spiral reinforced endotracheal tube with cuff and stylet, ID 10.0 mm, PVC, sterile (manufacturer’s official catalogue) | Comparable by category; same size and reinforcement, but with cuff and stylet: not interchangeable 1:1 |
| P. J. Dahlhausen (Magill series) | 44.000.11.0XX | Magill-type tube without cuff and without stylet with Murphy eye; series range verified in other sizes | Comparable by category; the 10.0 mm size not confirmed in public sources, pending verification |
| ENDOSID® (Asid Bonz) | Range 849xxx | Reinforced spiral line with Murphy eye; officially documented up to 9.0 mm | No direct match in 10.0 mm according to official catalogue; not applicable as an equivalent in this size |
| Teleflex (Rüsch® / Sheridan®), Medtronic (Shiley™), ICU Medical (Portex®), Intersurgical (InTube™) | Consult reference by size | Market families of reinforced endotracheal tubes covering large adult sizes | Comparable by category; verify datasheet and IFU (diameter, material, cuff, Murphy eye, reinforcement and regulatory classification) before replacing |
Important notice: there is no manufacturer-validated equivalence table for this reference; consult the Cahnos technical department before using this reference as an equivalence in specifications or tenders. These alternatives must not be treated as direct equivalents without prior field-by-field technical validation (measurements, material, geometry and regulations).
5. Selection tips and variants of interest
Size selection (usual practice in clinical use, not manufacturer specification): the ID of 10.0 mm is the maximum size in this family and is reserved for large adult patients or wide airways. As a general guide, in adults tubes of 7.0 to 10.0 mm are used depending on build and airway, always selecting the largest size compatible with the patient’s anatomy. As this is an uncuffed tube, size selection determines the seal: an insufficient size causes leaks and an excessive one can damage the tracheal mucosa.
Pre-intubation verification: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the 15 mm connector to the circuit. The uncuffed configuration is the appropriate option for procedures of limited duration and for patients in whom cuff inflation is preferably avoided.
Variants of interest in the catalogue: if your protocol requires an airtight seal or prolonged ventilation, consider the reinforced tube with cuff of the same size (Ref. ETA010C02A2); if insertion assistance is needed, Ref. ETAM10C02A1 (same size, with guide); and to complete the adult intubation trolley, cover the adjacent sizes in the family (ETA095002A2 and ETA090002A2). Single-use device: do not re-sterilise or reuse; dispose of it after removal according to the centre’s healthcare waste management protocols. For volume conditions, samples or hospital supply lead times, contact the Cahnos technical-commercial department.




Reviews