Description
1. Commercial Introduction
The reinforced oral endotracheal tube with cuff and Murphy eye, 4.5 mm internal diameter (Ref. ETA045C02A2), is the airway solution that anaesthesia, paediatrics, emergency and intensive care departments need when face mask ventilation is not viable. Manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the helical anti-kink reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, designed for the intubation trolley and high-turnover hospital consumables, guaranteeing a uniform and reliable standard in every procedure.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The helical reinforcement integrated into the PVC wall prevents tube collapse under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial procedures, prone positioning and complex surgical positions, as well as for paediatric patients who move their head during ventilation.
The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive-pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety route: if the tip of the tube rests against the tracheal or bronchial wall, respiratory flow continues through this opening and occlusion is never complete. The universal 15 mm connector (ISO 5356-1), radiopaque line and depth graduation allow connection to the circuit and radiographic verification of position. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications set out below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference (SKU) | ETA045C02A2 (Cahnos distributor’s own code; ETA series: reinforced with cuff, without guide) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 4.5 mm (paediatric calibre / reduced-calibre airway) |
| Reinforcement | Anti-kink helical spiral integrated into the tube wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Sealing (cuff inflation), with pilot balloon and self-sealing valve |
| Murphy eye | Present (distal lateral safety opening) |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, non-reusable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Indicative population | Paediatric (infants and young children) / reduced-calibre airway |
| Presentation | Box of 10 units |
| Regulatory standard | ISO 5361 (tracheal tubes and connectors); connector according to ISO 5356-1; sterilisation according to EN ISO 11135-1; verify CE/MDR marking of each batch |
Range of calibres confirmed in the Cahnos catalogue (ETA…C02A2 series, reinforced with cuff and Murphy eye, without guide):
| Reference | Internal diameter (ID) | Indicative population |
|---|---|---|
| ETA035C02A2 | 3.5 mm | Paediatric |
| ETA040C02A2 | 4.0 mm | Paediatric |
| ETA045C02A2 (this product) | 4.5 mm | Paediatric / reduced airway |
| ETA055C02A2 | 5.5 mm | Paediatric / adolescent |
| ETA060C02A2 | 6.0 mm | Small adult / tall paediatric |
| ETA065C02A2 | 6.5 mm | Adolescent / small adult |
| ETA080C02A2 | 8.0 mm | Adult |
| ETA085C02A2 | 8.5 mm | Adult / large adult |
| ETA090C02A2 | 9.0 mm | Large adult |
| ETA010C02A2 | 10.0 mm | Large adult |
Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The reference ETA045C02A2 is a code specific to the Cahnos catalogue (ETA series: reinforced oral tracheal tubes with cuff, without guide; technical nomenclature of the DEAFLUX line from DEAS S.r.l., Italy) and must not be confused with the official reference number of any specific manufacturer. To date there is no equivalence table validated by the manufacturer for this reference, so the following options are classified as comparable at category level (not interchangeable 1:1), pending technical verification against each manufacturer’s official data sheet:
| Reference / Line | Description | Degree of correspondence |
|---|---|---|
| 849045 / 849045A (ENDOSID® / Asid Bonz, via Medline) | Spiral reinforced endotracheal tube (Magill) with high-volume low-pressure cuff and Murphy eye, ID 4.5 mm, PVC, 15 mm connector | Comparable by category; code verified in official Medline EU catalogue. Cross-check inflation system, outer diameter and packaging |
| 44.000.20.045 (4400020045) (P. J. Dahlhausen) | Reinforced endotracheal tube with cuff (Woodbridge type), ID 4.5 mm, PVC, sterile | Comparable by category; code verified in authorised distributor’s data sheet. Confirm presence of Murphy eye and batch packaging |
| 118-45M (Safety-Flex, Mallinckrodt/Teleflex) | Reinforced tube with cuff and Murphy tip, ID 4.5 mm (series pattern) | Comparable by category; pending verification of official data sheet |
| Rüsch® / Sheridan® (Teleflex RUS-112480045), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical | Reinforced cuffed endotracheal tube ranges on the market in paediatric sizes | Comparable by category; not interchangeable 1:1 without verification of each manufacturer’s data sheet and IFU |
Comparable by category within the Cahnos catalogue in the same internal diameter 4.5 mm (not interchangeable 1:1):
| Reference | Description | Key difference |
|---|---|---|
| ETAM45C02A1 | Reinforced oral tube with cuff, insertion guide and Murphy eye, ID 4.5 mm | Adds included insertion stylet |
| ETA045002A2 | Reinforced oral tube without cuff, with Murphy eye, ID 4.5 mm | Without cuff |
| ETAN45C02 | Oral tube with cuff and Murphy eye, ID 4.5 mm | Without helical reinforcement |
| ETAN45002 | Oral tube without cuff or reinforcement, with Murphy eye, ID 4.5 mm | Without cuff or reinforcement |
| 841045 (ENDOSID) | Tube with low-pressure cuff and Murphy eye, ID 4.5 mm | Without helical reinforcement; verify inflation system and external diameter |
Fields to be checked before comparing: internal diameter (4.5 mm), material (medical-grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, 15 mm connector and helical reinforcement. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tender documents or bids or as a direct replacement for stock from other brands.
5. Selection tips and variants of interest
Size selection: the 4.5 mm ID is intended for paediatric patients (infants and young children) or those with a reduced airway calibre. As a general clinical practice guideline (not a manufacturer specification), in the paediatric range tubes of 3.5 to 5.0 mm are used depending on age, weight and anaesthetic assessment; always select the largest size compatible with the patient’s anatomy and the centre’s protocol.
Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the service has one available. In paediatric patients, adjust the seal to the minimum effective volume.
Pre-insertion verification: check the patency of the Murphy eye, the secure attachment of the 15 mm connector to the circuit and the correct condition of the cuff before insertion.
Relevant variants: if insertion assistance is required, consider Ref. ETAM45C02A1 (same size, with guide); if the procedure is short and it is preferred to avoid the cuff, Ref. ETA045002A2 (reinforced without cuff). Complete the intubation trolley stock with the adjacent sizes in the range (ETA040C02A2 and ETA055C02A2) and, for prolonged ventilation with risk of ventilator-associated pneumonia (VAP), consult the lines with subglottic suction lumen. Single-use product: do not re-sterilise or reuse. Contact the technical-commercial department of Cahnos for samples, volume conditions and reference approval for your tender.