We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament Polyglactin 910 Suture RAPID PGLAR Prime — Straight Needle Conventional Cutting GS48 mm, USP 2/0, Colourless Thread 2×75 cm (Box of 12 units)

96,83 €

Absorbable multifilament polyglactin 910 suture (PGLAR Prime) in RAPID version, with a straight needle with triangular point and conventional cutting edge of 48 mm (GS48). USP gauge 2/0, double colourless strand of 2×75 cm and non-grooved surface. Predictable absorption by hydrolysis in 40–45 days: retains 50% of tensile strength at 5 days and loses all its strength at 14 days. Sterile by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying. Indicated for soft tissue approximation, ligatures and ophthalmic surgery. Ref. AMP2L22GS4820.2 · Sold in boxes of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22GS4820.2

Description

Absorbable suture PGLAR Polyglactin 910 RAPID · Straight needle GS48

1. Product Presentation

At Cahnos we offer you an absorbable multifilament suture of polyglactin 910 (PGLAR) in RAPID version and Prime quality, designed for the supply of operating theatres, purchasing centres and ophthalmic surgery clinics. This reference incorporates a straight needle with triangular point and conventional cutting of 48 mm (GS48) and a double-strand configuration of 2×75 cm in USP gauge 2/0, undyed and non-grooved thread. Predictable mechanical behaviour, minimal tissue response and reliable knot tying, in a box of 12 units.

2. Technical explanation of the material and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, structured in a multifilament braid that provides flexibility, soft touch and great knot security. Its absorption occurs by hydrolysis, a predictable mechanism independent of the patient’s enzymatic activity: the thread degrades into substances that the body metabolises without generating relevant tissue reaction.

The RAPID variant is optimised for short-term support: it retains 50% of tensile strength at 5 days and loses 100% of its resistance at 14 days, with complete absorption between 40 and 45 days. The straight GS48 needle of 48 mm, with triangular conventional cutting point and non-grooved surface, facilitates penetration into firm tissues with absolute control of the path, being especially suitable for manual suturing on directly accessible surfaces, approximation stitches, superficial continuous sutures, ligatures and ophthalmic surgery procedures. The double-strand 2×75 cm format reduces handling in the operating theatre and increases yield per unit.

3. Technical Specifications

Parameter Specification
SKU Cahnos AMP2L22GS4820.2
Material Polyglactin 910 (PGLAR Prime), copolymer 90% glycolide / 10% L-lactide
Thread structure Braided multifilament, non-grooved surface
Gauge USP 2/0
Thread length 2×75 cm (double strand)
Needle shape Straight
Tip type Triangular — conventional cutting
Needle size GS48 (48 mm)
Colour Colourless
Absorption By hydrolysis, between 40 and 45 days
Sterilisation Gamma radiation; sterile, single-use
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units

Tensile strength retention profile after implantation:

Time point Tensile strength retention
5 days 50% of initial strength
14 days 0% (total loss of strength)
Complete absorption 40–45 days by hydrolysis

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate.

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer that cross-references this specific configuration (straight conventional cutting needle GS48 of 48 mm, USP gauge 2/0, undyed thread in double strand 2×75 cm) with references from other commercial houses; consult the technical department of Cahnos before using this information in tenders or in the direct substitution of references.

At category level, fast-absorbing polyglactin 910 corresponds to the market’s braided fast-absorbing synthetic absorbable sutures. The closest homologous family is VICRYL RAPIDE™ from Ethicon / Johnson & Johnson MedTech (polyglactin 910, same composition 90% glycolide / 10% L-lactide and same absorption profile 40–45 days with total loss of strength at 14 days), as well as the Safil Quick and Novosyn Quick ranges from B. Braun in the segment of multifilament absorbables with rapid loss of strength. Any code from these lines should be checked against its technical data sheet and IFU before proposing substitution, since needle nomenclatures, point type (conventional cutting versus reverse cutting) and configuration (single strand versus double strand) vary by manufacturer. The cited brands belong to their respective manufacturers and are mentioned only as an equivalence reference.

5. Selection tips and variants of interest

To choose the correct suture, verify three parameters: USP gauge (this model, USP 2/0, is intended for soft tissues of thin-medium thickness that require short-term support), needle geometry (straight conventional cutting for direct-access sutures with good control of the path; circular 3/8 or 1/2 variants are reserved for reduced fields) and configuration (the double-strand 2×75 cm format offers greater yield per unit).

Variants of interest within the Cahnos catalogue:

  • AMP2L22GS4820: same GS48 configuration, USP 2/0, undyed, in single strand of 75 cm.
  • AMP2L22GS4830 / AMP2L22GS4830.2: straight needle GS48, USP 3/0, undyed, in 75 cm and 2×75 cm.
  • AMP2L22GS6030 / AMP2L22GS6030.2: straight needle GS60 (60 mm), USP 3/0, undyed, in 75 cm and 2×75 cm.
  • AMP2L28GR1940: straight needle conical point GR19, USP 4/0, undyed, 70 cm, for microsurgery and more reduced fields.
  • AMP2L22HR2630.2: ½ circle cylindrical needle with taper point HR26, USP 3/0, undyed, 2×75 cm.

As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume, hospital supply agreements or equivalence queries, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR Prime), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament, non-grooved surface

Gauge

USP 2/0

Thread length

2 x 75 cm (double strand)

Tip type

Triangular — conventional cutting

Needle size

GS48 (48 mm)

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation

Presentation

Box of 12 units

Manufacturer reference

P2L22GS4820.2

Medida de aguja

GS 48

Usp

2/0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Conventional triangular

Forma de aguja

Straight, Straight Cut

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Polyglactin 910 Suture RAPID PGLAR Prime — Straight Needle Conventional Cutting GS48 mm, USP 2/0, Colourless Thread 2×75 cm (Box of 12 units)”

Your email address will not be published. Required fields are marked *