We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · 3/8 Circle Needle Triangular Point Precision Reverse Cutting XDS 19 mm Square Body · USP 3/0 · Colourless · 45 cm (Ref. P2L21XDS1930) · Box of 12 units

Original price was: 93,16 €.Current price is: 58,70 €.

Absorbable multifilament Polyglactin 910 (PGLAR PRIME) suture in RAPID version, with a ⅜ circle needle with a triangular point in precision reverse cutting edge (extra-long cutting edge) and a square body of 19 mm (XDS19 Prime profile). USP gauge 3/0, colourless non-grooved thread of 45 cm. Absorption by hydrolysis in 40–45 days, with 50% retention of tensile strength at 5 days and 0% at 14 days. Sterilised by gamma radiation and single-use, offers minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures, ophthalmic surgery and plastic-cosmetic procedures. Presentation in box of 12 units; minimum order of 10 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 10 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L21XDS1930

Description

1. Commercial Introduction

The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID in Prime quality (PREMISUT RAPID) is the reference option for B2B procurement for operating theatres, ophthalmology clinics, plastic and cosmetic surgery services and purchasing centres that need a synthetic absorbable suture with rapid absorption, exceptional handling and maximum knot security. Its ⅜ circle needle with precision reverse cutting triangular point and square body of 19 mm offers controlled penetration and a clean track, highly valued in skin, mucous membranes and tissues in tension areas. The colourless 45 cm thread provides maximum discretion on the surgical field.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure. In the RAPID variant, the thread is formulated to lose tensile strength rapidly: it retains 50% of the initial strength at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing, ligatures and ophthalmic surgery, where prolonged tensile support is not required.

The XDS needle (precision reverse cutting with extra-long cutting edge) concentrates the cutting edge at the tip, generates a clean entry hole by orienting the cut away from the wound, preserves the skin edge and prevents the cut from enlarging in the puncture bed. The square body optimises grip in the needle holder, preventing rotation and improving the precision of the surgical gesture. Absorption by hydrolysis is uniform and predictable, with minimal tissue reaction and excellent knot-tying capacity. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Characteristic Detail
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide
Structure Braided multifilament, non-ribbed
Thread colour Colourless (violet on request)
USP size 3/0 (metric 3, diameter 0.20 – 0.249 mm)
Thread length 45 cm
Needle shape 3/8 circle
Needle tip Triangular, precision reverse cutting (extra-long cutting edge)
Needle body Square
Needle size XDS 19 mm (Prime)
Quality Prime (PREMISUT RAPID)
Absorption By hydrolysis, 40 – 45 days
Sterilisation Gamma radiation, single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures, ophthalmic and plastic-cosmetic surgery
Presentation Box of 12 units
Factory reference P2L21XDS1930 · SKU Cahnos AMP2L21XDS1930

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable
Tissue reaction Minimal

3.3. Size equivalence

USP size Approximate diameter Metric size
3/0 0.20 – 0.249 mm 3

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used clinical reference multifilament absorbable in the surgical market. This reference shares material, USP 3/0 gauge, ⅜ circle curvature, reverse cutting needle and colourless or violet thread with the main polyglactin 910 lines on the market. Only codes verified in public catalogue sources and authorised distribution are listed; the comparison is declared at category level, not interchangeable 1:1, because the needle, body and/or absorption profile differ.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE™ (braided polyglactin 910, colourless) VR497 – USP 3/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 45 cm, box of 12 Comparable by category (not interchangeable 1:1) Same material, gauge, needle size (19 mm), curvature and thread length (45 cm), with similar rapid absorption profile (≈50% at 5 days, 0% at 10–12 days according to data sheet); the needle differs (PS-2 with round body versus XDS19 Prime with extra-long cutting edge and square body).
Ethicon (Johnson & Johnson MedTech) Coated VICRYL® (braided polyglactin 910, colourless) J427H – USP 3/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 70 cm Comparable by category (not interchangeable 1:1) Same material, gauge and needle size (19 mm); the absorption profile differs (standard VICRYL with 35-day tensile support versus RAPID), the thread length (70 cm) and the coating.
DemeTECH DemeCRYL™ (polyglactin 910) G1173024F4P – USP 3/0, 24 mm needle, ⅜ circle, reverse cutting, colourless, 70 cm, box of 12 Comparable by category (not interchangeable 1:1) Same material family, gauge and ⅜ reverse cutting geometry; the needle size differs (24 mm versus 19 mm), the absorption profile (standard DemeCRYL more prolonged versus RAPID 40–45 days), the thread length (70 cm) and the needle body.

In the same therapeutic block are the rapid absorption lines of B. Braun (Safil Quick / Novosyn Quick), comparable by category by material and absorption profile, although with their own codes depending on needle configuration; their specific codes must be verified against the manufacturer’s catalogue before any substitution.

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders.

5. Selection tips and variants of interest

USP 3/0 gauge is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucous membranes and soft tissue closures. The XDS19 Prime needle (precision reverse cutting with square body) is especially recommended in plastic and cosmetic surgery, dermatology and ophthalmology, where the needle passage must be clean and without tearing.

The 45 cm thread is designed for optimal use in microsurgery and reduced fields; if you require greater length, consider the same XDS19 Prime configuration in 75 cm (ref. P2L22XDS1930). You can also upgrade to an XDS24 Prime needle with 45 cm thread (ref. P2L21XDS2430) for tissues of greater consistency.

If you require greater tensile support, consider the PGLA – Polyglactin 910 range with standard absorption (56–72 days) or the PDO/PDS monofilament (180–210 days). The same XDS Prime needle is offered in other absorbable families in the catalogue (PGA, PGCL, PDO) to unify supplier. If you prefer a conventional precision cutting point, consult the XNS variant of the same PGLAR RAPID range; if you prefer a cylindrical body, the HR/HRP/HRT ranges. The colourless version offers maximum aesthetic discretion; if you require greater visibility in the field, request the same configuration in violet on request.

Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions or volume orders, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (90 % glycolide / 10 % L-lactide)

Structure

Braided multifilament, non-ribbed

Thread colour

Colourless (violet on request)

USP size

3/0 (metric 3, diameter 0.20–0.249 mm)

Thread length cm

45

Needle tip

Triangular, precision reverse cutting (extra-long cutting edge)

Needle body

Square

Needle size

XDS 19 mm (Prime)

Quality

Prime (PREMISUT RAPID)

Tensile strength 5 days

50% of initial strength

Tensile strength 14 days

0% (total loss of tensile support)

Sterilisation

Gamma radiation, single-use, not re-sterilisable

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures, ophthalmic and plastic-cosmetic surgery

Presentation

Box of 12 units

Minimum order

10 boxes

Manufacturer reference

P2L21XDS1930

Medida de aguja

XDS 19

Usp

3/0

Color

Colourless, Violet

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · 3/8 Circle Needle Triangular Point Precision Reverse Cutting XDS 19 mm Square Body · USP 3/0 · Colourless · 45 cm (Ref. P2L21XDS1930) · Box of 12 units”

Your email address will not be published. Required fields are marked *