Description
1. Commercial Introduction
The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID from the Prime range (PREMISUT RAPID) is the trusted solution for the professional who needs short-term tissue support with predictable behaviour and excellent handling. Its ⅜ circle needle with triangular point in precision conventional cutting with a 16 mm square body (XNS16) guarantees a clean and controlled penetration, ideal for tissue approximation, ligatures and ophthalmic surgery.
Available for B2B wholesale distribution in a box of 12 units, this reference combines a versatile gauge (USP 4/0), an undyed non-ribbed thread of 70 cm and top-tier mechanical performance for clinics, hospitals, ophthalmic centres and purchasing departments.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament format without ribbing. This structure provides excellent handling tolerance, smooth passage through tissue and secure knotting, with absorption by hydrolysis over a period of 40 to 45 days and minimal tissue reaction. The RAPID version is formulated to lose its tensile strength quickly: it retains approximately 50% at 5 days and 0% at 14 days, being suitable for tissues that only require support for a short period.
The 16 mm XNS needle combines a square body, which prevents rotation in the needle holder and improves the precision of the surgical gesture, with a triangular point in precision conventional cutting (extra cutting), designed for firm tissues and surfaces where a clean passage and minimal trauma are required. The undyed colour of the thread makes it especially suitable for ophthalmic surgery and procedures where minimising suture visibility is sought.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Detail |
| Material | Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide |
| Structure | Braided multifilament, non-ribbed |
| Thread colour | Colourless (violet on request) |
| USP size | 4/0 (metric 2, diameter 0.15 – 0.199 mm) |
| Thread length | 70 cm |
| Needle shape | ⅜ circle |
| Needle tip | Triangular, conventional precision cutting (extra cutting) |
| Needle body | Square |
| Needle size | XNS 16 mm (Prime) |
| Quality | Prime (PREMISUT RAPID) |
| Sterilisation | Gamma radiation |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Reference | P2L28XNS1640 (Warehouse SKU: AMP2L28XNS1640) |
3.2. Absorption profile and tensile strength retention
| Parameter | Value |
| Absorption type | Hydrolysis |
| Absorption time | 40 – 45 days |
| Tensile strength at 5 days | 50 % |
| Tensile strength at 14 days | 0 % |
| Absorption rate | Predictable |
| Tissue reaction | Minimal |
3.3. Size equivalence
| USP size | Approximate diameter | Metric size |
| 4/0 | 0.15 – 0.199 mm | 2 |
4. Equivalences and Cross-References
Polyglactin 910 is the most widespread absorbable multifilament material in the surgical market, and its rapid absorption line is comparable to the short-support braided sutures of major international manufacturers. Only references verified in public sources of authorised distribution are listed below; the comparison is at category level and does not imply 1:1 interchangeability.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon | VICRYL RAPIDE™ (polyglactin 910) | VR426 – USP 4/0, thread 70 cm, PS-2 needle 19 mm, ⅜ circle, colourless, braided, box of 12 | Comparable by category (not interchangeable 1:1) | Same material, gauge, length of 70 cm and rapid absorption profile (≈50% at 5 days, 0% at 12-14 days); the needle differs (PS-2 reverse cutting 19 mm vs XNS16 precision conventional cutting with square body) and the body (round vs square). |
| DemeTECH | DemeCRYL™ (polyglactin 910) | DemeCRYL 4/0 – 70 cm, needle 19 mm ⅜ circle reverse cutting, undyed/transparent | Comparable by category (not interchangeable 1:1) | Same material, gauge and length; standard absorption (56-72 days) according to catalogue vs the rapid profile of this reference; reverse cutting needle of 19 mm vs precision conventional cutting XNS16. |
In the same therapeutic block are also the rapid absorption lines of B. Braun (Safil Quick / Novosyn Quick), comparable by category by material and absorption profile, although with their own codes depending on needle configuration; their specific codes must be verified against the manufacturer’s catalogue before any substitution. There is no equivalence table validated by the manufacturer for this reference; consult with the technical department before using in tenders.
5. Selection tips and variants of interest
The USP 4/0 gauge (metric 2) is indicated for delicate tissues and moderate tension: skin, mucous membranes, subcutaneous tissue and ophthalmic surgery. The ⅜ circle needle with precision conventional cutting point and square body is especially recommended in firm tissues where a clean and controlled passage is needed.
- If your protocol requires a thicker gauge, consider the USP 3/0 version with 75 cm thread from the same XNS family (ref. P2L22XNS1630).
- If you prefer reverse cutting for skin and tissues of greater resistance, consult the XDS variant of the same PGLAR RAPID range.
- If you need a longer tensile support, consider the PGLA range – Polyglactin 910 with standard absorption (56–72 days) with the same XNS16 needle (e.g. P1L21XNS1640).
- If you require greater thread visibility, request the violet coloured version on demand.
- For other compositions of the same format, the PGA RAPID range (polyglycolic acid) can be considered.
Contact our technical-commercial team to optimise your order by boxes and benefit from special B2B conditions.





Reviews
There are no reviews yet.