We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Multifilament Absorbable Suture PGLAR Polyglactin 910 RAPID Prime · ⅜ Circle Reverse Cutting Triangular Point Needle DS36 (36 mm) · USP 2/0 (Metric 3) · Colourless 2×75 cm · Box of 12 units (Ref. P2L22DS3620.2)

85,40 €

Multifilament absorbable suture of Polyglactin 910 (PGLAR) in Prime quality, RAPID variant with fast and predictable absorption: retains 50% of tensile strength at 5 days and loses it at 14 days, with complete reabsorption by hydrolysis between 40 and 45 days. Mounted with ⅜ circle needle with reverse cutting triangular point, 36 mm (DS36), USP size 2/0 (metric 3) and colourless fluted thread in double format 2×75 cm: two ready-to-use strands per package to maximise operating theatre efficiency. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P2L22DS3620.2 · Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS3620.2

Description

1. Commercial Introduction

The PGLAR Polyglactin 910 RAPID Prime multifilament absorbable suture is the accelerated-absorption surgical closure reference for general and ambulatory surgery theatres, ophthalmology departments, emergency services and B2B purchasing centres that require a braided, flexible thread with early and fully predictable loss of strength. This presentation mounts a ⅜ circle 36 mm needle with triangular body and reverse cutting point (DS36), USP 2/0 gauge and undyed thread in a double strand 2×75 cm format: two threads per pack that optimise performance in each procedure and reduce the cost per suture. It is supplied in a box of 12 sterile units, with batch traceability and factory reference P2L22DS3620.2.

2. Technical explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish and coating that favours sliding, very smooth handling and a firm, secure knot. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— over a period of 40 to 45 days, retaining 50% of the initial tensile strength at 5 days and losing it completely at 14 days. This profile makes it particularly suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture, in many cases without the need to remove the material.

The ⅜ circle needle (135°) with triangular body and reverse cutting point (reverse cutting) passes through firm, non-compliant tissues with a clean, controlled passage, minimising tearing of the wound edge. The product is sterilised by gamma radiation, is single-use and not re-sterilisable: check the integrity of the packaging and the expiry date before each procedure.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS3620.2 · SKU AMP2L22DS3620.2)

Parameter Specification
Material Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant
Thread structure Braided multifilament with grooved finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 2/0 (metric 3; approximate diameter 0.30 – 0.339 mm according to Pharmacopoeia)
Thread colour Colourless (undyed)
Thread length 2 × 75 cm (double strand format)
Needle shape ⅜ circle (3/8, 135°)
Needle body and point Triangular reverse cutting (reverse cutting), body and point
Needle size DS36 (36 mm)
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Tensile strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Factory reference P2L22DS3620.2
SKU Cahnos AMP2L22DS3620.2

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

Absorption by hydrolysis with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate. The profile cited corresponds to the RAPID formulation; it must not be confused with standard polyglactin 910 (PGLA line, absorption 56 – 72 days).

4. Equivalences and Cross-References

Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread fast-acting braided multifilament absorbable category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line from Ethicon (Johnson & Johnson MedTech). This reference shares material, accelerated absorption profile (≈42 days), tensile retention (50% at 5 days / 0% at 14 days), USP 2/0 gauge, ⅜ circle curvature, reverse cutting point, undyed 75 cm thread and 36 mm needle with the following codes, whose attributes have been verified in authorised distribution catalogues:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9961 – USP 2/0, 36 mm needle in ⅜ circle, reverse cutting point, colourless 75 cm thread, box of 12 Comparable by category (not interchangeable 1:1) Same material, rapid absorption, USP 2/0 gauge, ⅜ curvature, reverse cutting, 36 mm needle and 75 cm length; they differ in format (single strand versus double 2×75 cm), needle nomenclature and braid coating (calcium stearate). Code confirmed in authorised distribution.
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9938 – USP 2/0, PSLX needle of 38 mm in ⅜ circle, reverse cutting, colourless 75 cm thread, box of 12 Comparable by category (not interchangeable 1:1) Same material, rapid absorption, USP 2/0 gauge, undyed 75 cm thread and ⅜ reverse cutting needle; they differ in needle size (38 mm versus DS36 of 36 mm) and the double format. Code confirmed in authorised distribution.

Homologous ranges in the rapid-absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category in terms of material and absorption profile; for the exact combination of USP 2/0 / DS36 reverse cutting needle / double thread 2×75 cm, their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56 – 72 days) is not equivalent to this RAPID version. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders, verifying in each official datasheet the USP 2/0 gauge (metric 3), the ⅜ circle curvature, the needle type and size (triangular reverse cutting 36 mm), the thread length (2×75 cm) and the undyed colour.

5. Selection tips and variants of interest

The USP 2/0 gauge (metric 3) with a ⅜ circle needle with a 36 mm triangular reverse cutting point offers an optimal balance between initial strength and handling, indicated for skin closure, subcutaneous tissue, mucous membranes, approximation of soft tissues, ligation of small and medium-calibre vessels and ophthalmic surgery, with early loss of strength that in many indications avoids the removal of stitches. The double strand format (2×75 cm) maximises performance per pack in high-turnover departments and centralised replenishment.

Within the same PGLAR Polyglactin 910 RAPID Prime range with reverse cutting needle, Cahnos offers complementary configurations: the same DS36 needle in USP 0 gauge with double thread (AMP2L22DS3610.2), the single-strand version of this same reference (AMP2L22DS3620), the DS26 needle in USP 2/0 and 3/0 with double thread (AMP2L22DS2620.2 and AMP2L22DS2630.2) and the DS24 needle in USP 2/0 with double thread (AMP2L22DS2420.2). For a longer tensile support profile, consider the PGLA family of standard polyglactin 910 (absorption 56 – 72 days), for example P1L12DS3620 with the same DS36 needle in USP 2/0.

The undyed version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand. As this is a sterile single-use product, store it in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR) – copolymer 90 % glycolide / 10 % L-lactide, RAPID variant

Thread structure

Multifilament braided fluted

Quality

Prime (PREMISUT RAPID range)

USP size

2/0 (metric 3)

Thread length

2 × 75 cm (double strand)

Needle shape

⅜ circle (3/8, 135°)

Needle type

Triangular reverse cutting (reverse cutting), body and point

Needle size

DS36 (36 mm)

Sterilisation

Gamma radiation (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Manufacturer reference

P2L22DS3620.2

Medida de aguja

DS 36

Usp

2/0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Multifilament Absorbable Suture PGLAR Polyglactin 910 RAPID Prime · ⅜ Circle Reverse Cutting Triangular Point Needle DS36 (36 mm) · USP 2/0 (Metric 3) · Colourless 2×75 cm · Box of 12 units (Ref. P2L22DS3620.2)”

Your email address will not be published. Required fields are marked *