We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · ⅜ Circle Reverse Cutting Triangular Point Needle DS36 (36 mm) · USP Size 0 (Metric 3.5) · Colourless Thread 2×75 cm · Box of 12 units (Ref. P2L22DS3610.2)

87,59 €

Absorbable multifilament suture Polyglactin 910 RAPID (PGLAR Prime) with a ⅜ circle reverse cutting triangular point needle, 36 mm (DS36), USP size 0 and colourless fluted thread in a double-strand 2×75 cm presentation. Predictable absorption by hydrolysis in 40–45 days, retaining 50% of tensile strength at day 5 and losing it at day 14, ideal for fast-healing tissues without suture removal. Sterilised by gamma radiation, single-use and minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P2L22DS3610.2 · box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS3610.2

Description

1. Commercial Introduction

The absorbable multifilament suture PGLAR Poliglactina 910 RAPID Prime is the reference accelerated-absorption surgical closure for general and day surgery operating theatres, ophthalmology departments, emergency rooms and B2B purchasing centres that require a braided, flexible thread with early and fully predictable loss of strength. This presentation mounts a ⅜ circle 36 mm needle with triangular body and reverse cutting point (DS36), USP 0 gauge and uncoloured thread in a double-strand 75 cm format: two ready-to-use threads per pack that optimise performance in each intervention. It is supplied in a box of 12 sterile units, with batch traceability and factory reference P2L22DS3610.2.

2. Technical explanation

Poliglactina 910 (PGLAR) is an absorbable synthetic copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish and coating that favours thread slippage, very smooth handling and a firm, secure knot even in medium gauges such as USP 0. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis within a predictable period of 40 to 45 days, retaining 50% of the initial tensile strength at 5 days and losing it completely at 14 days; this profile makes it especially suitable for skin, mucous membranes, subcutaneous tissue and temporary approximation of soft tissues where material removal is not required.

The ⅜ circle needle (135°) with reverse cutting triangular point combines a triangular body with a cutting edge that penetrates firm and non-compliant tissues with a clean, controlled passage, minimising tearing of the wound edge. The product is sterilised by gamma radiation, is single-use and non-reesterilisable: check the integrity of the packaging and the expiry date before each intervention.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS3610.2 · SKU AMP2L22DS3610.2)

Parameter Specification
Material Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant
Thread structure Braided multifilament with grooved finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 0 (metric 3.5)
Thread colour Colourless (undyed)
Thread length 2 × 75 cm (double strand)
Needle shape ⅜ circle (3/8, 135°)
Needle body and point Triangular reverse cutting (reverse cutting), size DS36 (36 mm)
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Tensile strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Factory reference P2L22DS3610.2
SKU Cahnos AMP2L22DS3610.2

3.2. Absorption profile and tensile strength retention

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

Absorption by hydrolysis with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate.

4. Equivalences and Cross-References

Rapid-absorption poliglactina 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable suture in the surgical market, whose international clinical reference is the Coated VICRYL RAPIDE line from Ethicon (Johnson \u0026 Johnson MedTech). This reference shares material, accelerated absorption profile (≈42 days), tensile retention (50% at 5 days / 0% at 14 days), ⅜ circle curvature, reverse cutting point and uncoloured colour with the following verified codes:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) Coated VICRYL RAPIDE (braided polyglactin 910, colourless) W9933 – USP 2/0, PRIME needle 26 mm in ⅜ circle, reverse cutting point, colourless thread 75 cm, box of 12 Comparable by category (not interchangeable 1:1) Same material and rapid absorption profile; they differ in gauge (USP 2/0 vs USP 0) and needle size (26 mm vs DS36 36 mm). Code confirmed in Ethicon EMEA catalogue and in authorised distributors.
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9932 – USP 3/0, PS Prime needle 26 mm, ⅜ circle, reverse cutting point, uncoloured thread 75 cm Comparable by category (not interchangeable 1:1) Same needle configuration and material family; they differ in gauge (3/0 vs 0) and needle size (26 mm vs 36 mm). Code confirmed in official Ethicon EMEA catalogue.

As homologous ranges in the rapid absorption segment, Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) are listed, comparable by category for material and absorption profile, although for the exact combination USP 0 / DS36 reverse cutting needle / double thread 2×75 cm their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.

There is no equivalence table validated by the manufacturer; consult with the technical department before use in tenders, verifying in each official datasheet the gauge USP 0 (metric 3.5), the ⅜ circle curvature, the needle type and size (reverse cutting triangular 36 mm), the thread length (2×75 cm) and the uncoloured colour.

5. Selection tips and variants of interest

The USP 0 gauge (metric 3.5) with ⅜ circle reverse cutting triangular point needle 36 mm offers high initial strength with clean passage in firm tissues, indicated for tissue approximation, ligatures and ophthalmic surgery. The double-strand format (2×75 cm) optimises performance per pack in high-turnover services and centralised replenishment.

Within the same PGLAR Poliglactina 910 RAPID range with ⅜ circle reverse cutting needle, Cahnos offers complementary configurations: the same DS36 needle in USP 2/0 gauge with 75 cm thread (SKU AM2L22DS3620), the DS26 Prime needle in USP 3/0 (SKU AMP2L22DS2630) and the ½ circle HS40 variant in USP 0 with 90 cm thread (SKU AM2L23HS4010). For a longer tensile support profile, consider the standard poliglactina 910 PGLA family (absorption 56–72 days), for example P1L12RDS3602.2 with DS36 needle in USP 2 gauge and double violet thread. The uncoloured version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand.

As it is a sterile single-use product, store it in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each intervention. For special B2B conditions, volume orders or equivalences from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight RAPID variant

Thread structure

Multifilament braided fluted

Quality

Prime (PREMISUT RAPID range)

Gauge

USP 0 (metric 3.5)

Thread length

2 x 75 cm (double strand)

Needle shape

3/8 circle (135°)

Needle type

Reverse cutting triangular point, size DS36 (36 mm)

Sterilisation

Gamma radiation (single-use, not re-sterilisable)

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Manufacturer reference

P2L22DS3610.2

Medida de aguja

DS 36

Usp

0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · ⅜ Circle Reverse Cutting Triangular Point Needle DS36 (36 mm) · USP Size 0 (Metric 3.5) · Colourless Thread 2×75 cm · Box of 12 units (Ref. P2L22DS3610.2)”

Your email address will not be published. Required fields are marked *