Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime | 3/8 Circle Needle Triangular Reverse Cutting Point 26 mm (DS26) | USP 3/0 | Colourless | Double Thread 2×75 cm | PREMISUT RAPID · Box of 12 units (Ref. P2L22DS2630.2)

84,84 €

Absorbable multifilament suture PREMISUT RAPID Prime of polyglactin 910 (PGLAR) with a ⅜ circle body and reverse cutting triangular point of 26 mm (DS26 profile), gauge USP 3/0 (metric 2) and colourless fluted thread in a double-thread presentation of 2 × 75 cm. Predictable absorption by hydrolysis in 40–45 days: retains 50% of tensile strength at 5 days and loses it completely at 14 days. Sterilised by gamma radiation, single-use, with minimal tissue reaction and excellent knot tying. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P2L22DS2630.2 · Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS2630.2

Description

1. Commercial Introduction

The PGLAR Polyglactin 910 RAPID Absorbable Multifilament Suture in Prime quality (PREMISUT RAPID range) is the accelerated-absorption surgical closure solution for hospitals, general and day surgery operating theatres, emergency departments, ophthalmology clinics and minor surgery. Its ⅜-circle needle with triangular reverse-cutting point (reverse cutting) of 26 mm ensures clean penetration in fine and firm tissues, while the double-strand presentation (2 × 75 cm) maximises yield per unit: two mounted strands ready for two consecutive sutures. A cost-effective and predictable option for B2B purchasing centres, supplied in a box of 12 units.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a lubricant coating and a grooved finish that promotes thread glide, very smooth handling and a firm, secure knot. In the RAPID variant (low molecular weight polyglactin 910), the thread loses tensile strength in an accelerated and programmed manner: it retains 50% of initial strength at 5 days and 0% at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucosa, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery.

The reverse-cutting needle directs the cutting edge away from the wound, creating a clean entry hole that preserves the skin edge and avoids enlarging the cut in the puncture bed. Prime quality ensures consistency of sharpness and finish batch to batch. Sterile single-use product, not to be re-sterilised.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS2630.2 · SKU AMP2L22DS2630.2)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant
Thread structure Braided coated multifilament, fluted finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 3/0 (metric 2)
Thread diameter 0.20 – 0.249 mm (indicative, according to USP Pharmacopoeia)
Thread colour Colourless (undyed)
Thread length 2 × 75 cm (2 strands of 75 cm per unit)
Needle shape 3/8 circle (⅜ circular, 135°)
Needle tip Triangular, reverse cutting (reverse cutting), triangular body and point
Needle size DS 26 mm (Prime)
Swaged Double suture: 1 needle per strand, 2 strands per unit
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Commercial format Box of 12 units
Factory reference P2L22DS2630.2 · SKU Cahnos AMP2L22DS2630.2

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

3.3. Gauge equivalence (USP Pharmacopoeia)

USP size Metric size Approximate diameter
3/0 (this product) 2 0.20 – 0.249 mm
4/0 1.5 0.15 – 0.199 mm
2/0 3 0.30 – 0.339 mm

3.4. Reference code decoding

The official reference P2L22DS2630.2 breaks down as follows: P (Prime range) + 2L22 (75 cm thread in PGLAR family) + DS26 (⅜-circle needle with triangular reverse-cutting point of 26 mm, triangular body and point) + 30 (USP 3/0 gauge) + .2 (double presentation, 2 threads of 75 cm). Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.

4. Equivalences and Cross-References

Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line (low molecular mass polyglactin 910), with which this reference shares material, hydrolysis absorption mechanism, accelerated tensile loss profile (50% at 5 days / 0% at 14 days), USP 3/0 gauge, ⅜-circle curvature, 26 mm reverse-cutting needle, undyed thread and box of 12 units. Only the code whose attributes have been verified in authorised distribution catalogues is included; none of these references should be considered 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (J&J MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9932 – USP 3/0, PS needle 26 mm in ⅜ circle, reverse cutting point, colourless 75 cm thread, box of 12 Comparable by category (not interchangeable 1:1) Almost complete attribute match: same material (rapid-absorption polyglactin 910), USP 3/0 gauge, ⅜-circle curvature, 26 mm reverse-cutting point, undyed 75 cm thread and box of 12 units format; they differ in needle nomenclature (PS vs DS26), manufacturer, exact braid coating and configuration (1 thread of 75 cm vs 2 × 75 cm of this reference). Code verified in authorised distributors.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tendering. Comparable ranges in the rapid-absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast / DemeQUICK (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category, material and absorption profile, although their specific codes for the exact combination USP 3/0 / DS 26 mm reverse-cutting needle / double thread 2 × 75 cm must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not equivalent to this RAPID version.

5. Selection tips and variants of interest

USP 3/0 gauge (metric 2) is a common choice for skin, mucosa, subcutaneous tissue, paediatrics and procedures with healing times of 5 to 10 days where short-term tensile support and early absorption are required: conjunctival and ophthalmic suture, mucosa approximation, small vessel ligation and minor surgery. The ⅜-circle reverse-cutting 26 mm needle is especially recommended when a firm, precise passage through skin or mucosa is needed without tearing the edge. The double-thread format (2 × 75 cm) provides two sterile strands per package, optimising yield per box.

Within the same PGLAR Polyglactin 910 RAPID Prime range with reverse-cutting needle, Cahnos offers complementary configurations to tailor the reference to the protocol:

SKU Variant
AMP2L22DS2630.2 (P2L22DS2630.2) PGLAR RAPID Prime, DS26 reverse-cutting needle, USP 3/0, undyed, 2 × 75 cm (this product)
AMP2L22DS2630 (P2L22DS2630) PGLAR RAPID Prime, same needle and gauge, single 75 cm thread
AMP2L22DS1930.2 (P2L22DS1930.2) PGLAR RAPID Prime, DS19 reverse-cutting needle, USP 3/0, undyed, 2 × 75 cm (shorter needle)
AMP2L22DS2430.2 (P2L22DS2430.2) PGLAR RAPID Prime, DS24 reverse-cutting needle, USP 3/0, undyed, 2 × 75 cm
AMP2L22DS1940 (P2L22DS1940) PGLAR RAPID Prime, DS19 needle, USP 4/0, undyed, 75 cm (finer gauge)
AMP2L22DRT1630 (P2L22DRT1630) PGLAR RAPID Prime, ⅜ trocar point needle DRT16, USP 3/0, undyed, 75 cm (Tapercut profile)

The colourless version offers maximum aesthetic discretion in the surgical field; if greater visibility is required, request the same configuration in dyed thread on demand. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Quality

Prime (PREMISUT RAPID range)

USP size

3/0 (metric 2)

Thread diameter

0.20 – 0.249 mm (indicative, USP Pharmacopoeia)

Thread length

2 × 75 cm (2 strands per unit)

Needle shape

3/8 circle (⅜, 135°)

Needle tip

Triangular reverse cutting (reverse cutting), triangular body and point

Swaged

Double suture: 1 needle per strand, 2 strands per unit

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

P2L22DS2630.2

Medida de aguja

DS 26

Usp

3/0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)