Description
1. Introduction
PREMISUT RAPID is Cahnos’ rapid-action absorbable multifilament suture line, formulated in Polyglactin 910 for procedures where tissue quickly recovers its strength and prolonged support is not required. The Prime version incorporates a silicone-free atraumatic needle for a cleaner passage and less tissue damage, with excellent knotting, sliding and knot security behaviour.
2. Technical explanation
The PGLAR Polyglactin 910 RAPID suture is a braided copolymer of 90 % glycolide and 10 % L-lactide that is reabsorbed by hydrolysis, leaving no residues and with minimal tissue response. Its rapid absorption profile makes it suitable for approximating tissues with accelerated healing: skin, mucosa, superficial subcutaneous tissue and ophthalmic surgery. The ⅜ circle needle with reverse cutting triangular point (body and point in triangular section) penetrates firm and dense tissues without the cutting edge cutting towards the wound edge, preventing tearing when the needle exits; it is the geometry of choice in dermis, mouth and plastic and aesthetic surgery. The colourless grooved thread improves knot grip and reduces the sawing effect.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Material | Polyglactin 910 (90 % glycolide / 10 % L-lactide) |
| Structure | Braided grooved multifilament, undyed |
| USP size | 2/0 |
| Thread length | 75 cm |
| Needle | ⅜ circle, triangular reverse cutting point (reverse cutting), 36 mm |
| Absorption | By hydrolysis, 40-45 days |
| Tensile retention | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation |
| Presentation | Box of 12 units |
| Reference | P2L22DS3620 |
Strength and absorption profile:
| Time | Retained tensile strength | Thread condition |
|---|---|---|
| 5 days | ≈ 50 % | In degradation process |
| 14 days | 0 % | No useful strength |
| 40-45 days | — | Complete absorption by hydrolysis |
4. Equivalences and Cross-References
This suture complies with the international standard for rapid-absorption polyglactin 910, whose reference family on the market is VICRYL RAPIDE from Ethicon (Johnson & Johnson MedTech), verified in the GUDID/FDA regulatory database as a synthetic absorbable multifilament polyglactin 910 suture (GMDN: polyester suture, bioabsorbable, multifilament, non-antimicrobial). There is no equivalence table validated by the manufacturer that cross-references this specific reference (⅜ circle needle, 36 mm reverse cutting, USP 2/0, 75 cm, colourless) with codes from other brands; consult the technical department before use in tenders. For any substitution, the following must be verified field by field: USP gauge (2/0), thread length (75 cm), needle geometry (⅜ circle, reverse cutting, 36 mm), point type, colour and presentation.
5. Selection tips and variants of interest
For the same DS36 mm needle point in Polyglactin 910 RAPID Prime, Cahnos offers the variant in USP 0 gauge with 75 cm thread (ref. P2L22DS3610) and the double-thread format 2 x 75 cm in USP 2/0 (ref. P2L22RDS3620.2), indicated for prolonged procedures or high-volume operating theatres. If a ½ circle needle arc is required, the HS36 mm family in USP 2/0 with 90 cm thread (ref. P2L23HS3620) facilitates work in deep spaces, and for finer sutures in cosmetic areas, the DS19 mm needle is available in USP 5/0 and 4/0 (refs. P2L22DS1950 and P2L22DS1940). For standard healing tissues (not rapid), evaluate the equivalent line of normal-absorption Polyglactin 910; for any doubt regarding indication or gauge selection, contact our technical service.





Reviews
There are no reviews yet.