We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID (PREMISUT RAPID Prime) — Triangular Needle 3/8 Circle Reverse Cutting DS36 mm, USP 2/0, Thread 75 cm, Colourless | Box of 12 units | Ref. P2L22DS3620

Original price was: 42,70 €.Current price is: 34,80 €.

Absorbable multifilament suture PGLAR Polyglactin 910 RAPID (PREMISUT RAPID Prime) with atraumatic ⅜ circle needle, triangular reverse cutting point (reverse cutting) of 36 mm. Gauge USP 2/0, colourless grooved thread of 75 cm. Rapid absorption by hydrolysis (40-45 days), ideal for accelerated healing tissues, ophthalmic, plastic and dermatological surgery. Sterile by gamma radiation. Box of 12 units. Manufacturer’s reference: P2L22DS3620.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS3620

Description

1. Introduction

PREMISUT RAPID is Cahnos’ rapid-action absorbable multifilament suture line, formulated in Polyglactin 910 for procedures where tissue quickly recovers its strength and prolonged support is not required. The Prime version incorporates a silicone-free atraumatic needle for a cleaner passage and less tissue damage, with excellent knotting, sliding and knot security behaviour.

2. Technical explanation

The PGLAR Polyglactin 910 RAPID suture is a braided copolymer of 90 % glycolide and 10 % L-lactide that is reabsorbed by hydrolysis, leaving no residues and with minimal tissue response. Its rapid absorption profile makes it suitable for approximating tissues with accelerated healing: skin, mucosa, superficial subcutaneous tissue and ophthalmic surgery. The ⅜ circle needle with reverse cutting triangular point (body and point in triangular section) penetrates firm and dense tissues without the cutting edge cutting towards the wound edge, preventing tearing when the needle exits; it is the geometry of choice in dermis, mouth and plastic and aesthetic surgery. The colourless grooved thread improves knot grip and reduces the sawing effect.

3. Technical Specifications

Parameter Specification
Material Polyglactin 910 (90 % glycolide / 10 % L-lactide)
Structure Braided grooved multifilament, undyed
USP size 2/0
Thread length 75 cm
Needle ⅜ circle, triangular reverse cutting point (reverse cutting), 36 mm
Absorption By hydrolysis, 40-45 days
Tensile retention 50% at 5 days; 0% at 14 days
Sterilisation Gamma radiation
Presentation Box of 12 units
Reference P2L22DS3620

Strength and absorption profile:

Time Retained tensile strength Thread condition
5 days ≈ 50 % In degradation process
14 days 0 % No useful strength
40-45 days — Complete absorption by hydrolysis

4. Equivalences and Cross-References

This suture complies with the international standard for rapid-absorption polyglactin 910, whose reference family on the market is VICRYL RAPIDE from Ethicon (Johnson & Johnson MedTech), verified in the GUDID/FDA regulatory database as a synthetic absorbable multifilament polyglactin 910 suture (GMDN: polyester suture, bioabsorbable, multifilament, non-antimicrobial). There is no equivalence table validated by the manufacturer that cross-references this specific reference (⅜ circle needle, 36 mm reverse cutting, USP 2/0, 75 cm, colourless) with codes from other brands; consult the technical department before use in tenders. For any substitution, the following must be verified field by field: USP gauge (2/0), thread length (75 cm), needle geometry (⅜ circle, reverse cutting, 36 mm), point type, colour and presentation.

5. Selection tips and variants of interest

For the same DS36 mm needle point in Polyglactin 910 RAPID Prime, Cahnos offers the variant in USP 0 gauge with 75 cm thread (ref. P2L22DS3610) and the double-thread format 2 x 75 cm in USP 2/0 (ref. P2L22RDS3620.2), indicated for prolonged procedures or high-volume operating theatres. If a ½ circle needle arc is required, the HS36 mm family in USP 2/0 with 90 cm thread (ref. P2L23HS3620) facilitates work in deep spaces, and for finer sutures in cosmetic areas, the DS19 mm needle is available in USP 5/0 and 4/0 (refs. P2L22DS1950 and P2L22DS1940). For standard healing tissues (not rapid), evaluate the equivalent line of normal-absorption Polyglactin 910; for any doubt regarding indication or gauge selection, contact our technical service.

Additional information

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide)

Structure

Multifilament braided fluted

Needle

⅜ circle, reverse cutting triangular point, 36 mm

Sterilisation

Gamma radiation

Presentation

Box of 12 units

Reference

P2L22DS3620

Use

Tissue approximation, ligatures, ophthalmic, plastic and dermatological surgery

Medida de aguja

DS 36

Usp

2/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID (PREMISUT RAPID Prime) — Triangular Needle 3/8 Circle Reverse Cutting DS36 mm, USP 2/0, Thread 75 cm, Colourless | Box of 12 units | Ref. P2L22DS3620”

Your email address will not be published. Required fields are marked *