Description
1. Commercial Introduction
The multifilament absorbable suture PREMISUT RAPID of polyglactin 910 (PGLAR) in Prime grade is the benchmark accelerated-absorption surgical closure for general and ambulatory surgery operating theatres, emergency departments, ophthalmology clinics and B2B purchasing centres that need a braided, flexible thread with early and fully predictable strength loss.
Its ⅜ circle 30 mm needle with reverse cutting triangular body and point (DS30) pierces firm and non-compliant tissues with a clean and controlled passage without tearing the skin edge. The double thread 2 × 90 cm format provides twice the usable material per envelope, optimising performance per unit and reducing cost per procedure. Presentation in a box of 12 sterile units with batch traceability and factory reference P2L23DS3010.2.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a fluted finish that promotes thread glide, very smooth handling and a firm, secure knot.
In the RAPID variant (low molecular weight), absorption occurs by hydrolysis — a predictable process independent of the patient’s enzymatic activity — within 40 to 45 days: it retains 50% of initial tensile strength at 5 days and loses it completely at 14 days. This profile makes it particularly suitable for fast-healing superficial tissues (skin closure, mucosa, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture, in many cases without the need to remove stitches.
The ⅜ circle (135°) needle with triangular reverse cutting body and point (reverse cutting) directs the cutting edge away from the wound, creating a clean entry hole that preserves the skin edge. Product sterilised by gamma radiation, single-use and not re-sterilisable: check the integrity of the packaging and the expiry date before each procedure.
3. Technical Specifications
3.1. General characteristics (Ref. P2L23DS3010.2 · SKU AMP2L23DS3010.2)
| Parameter | Specification |
| Material | Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime |
| Gauge | USP 0 (metric 3.5; approximate diameter 0.35 – 0.399 mm according to Pharmacopoeia) |
| Thread colour | Colourless (undyed) |
| Thread length | 2 × 90 cm (double thread) |
| Needle shape | ⅜ circle (3/8, 135°) |
| Needle body and point | Triangular reverse cutting (reverse cutting), size DS30 (30 mm) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Factory reference | P2L23DS3010.2 |
| SKU Cahnos | AMP2L23DS3010.2 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
Profile corresponding to the RAPID formulation; must not be confused with standard polyglactin 910 (PGLA line, absorption 56 – 72 days).
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 0 | 3.5 | 0.35 – 0.399 mm (indicative, according to Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widespread categories of rapid-action braided multifilament absorbable in the surgical market. The international clinical benchmark is the Coated VICRYL RAPIDE™ line (Ethicon / Johnson & Johnson MedTech), which shares composition (90% glycolide / 10% L-lactide), braided structure, undyed thread and the same accelerated absorption profile (strength loss at 14 days and absorption around 42 days).
For the exact configuration of this datasheet (USP 0 gauge, ⅜ circle reverse cutting needle 30 mm, Prime grade, undyed thread and double thread configuration 2 × 90 cm) it has not been possible to verify in public sources a specific VICRYL RAPIDE code that simultaneously meets all attributes, therefore it is not included in the table and any substitution must be checked against the official catalogue and the manufacturer’s IFU.
Homologous ranges in the rapid absorption segment include Safil Quick™ and Novosyn Quick™ (B. Braun), DemeCRYL™ Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; nor is a verified code available for the exact combination USP 0 / needle 30 mm / reverse cutting / 2 × 90 cm (pending confirmation from each manufacturer before use). Standard VICRYL (absorption 56 – 72 days) is not comparable to this RAPID version due to its longer strength retention profile.
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official datasheet the USP 0 gauge (metric 3.5), the ⅜ circle curvature, the needle type and size (reverse cutting triangular 30 mm), the thread length and number (2 × 90 cm) and the undyed colour.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) is one of the most versatile: indicated for approximation of subcutaneous tissues, superficial fascia, skin and mucosa closure, ligation of small and medium-calibre vessels and ophthalmic surgery, with good initial strength and rapid reabsorption that avoids removal in fast-healing tissues. The ⅜ circle reverse cutting needle 30 mm is especially recommended in restricted working fields and firm tissues, where a clean passage without tearing the edge is required.
Within the same PGLAR Polyglactin 910 RAPID range with reverse cutting needle, Cahnos offers complementary configurations: the same DS30 needle in Normal grade (SKU AM2L23DS3010) and in Prime single thread format 1 × 90 cm (SKU AMP2L23DS3010), the DS30 needle in USP 2/0 gauge (AM2L22DS3020 and Prime AMP2L22DS3020), the DS36 needle in USP 2/0 and USP 0 (AM2L22DS3620 / AM2L22DS3610) and the ½ circle reverse cutting needle HS40 in USP 0 (AMP2L23HS4010) for deeper tissues. If your protocol prefers a taper point, consult the HR family; and if you need the same absorption profile in rapid polyglycolic acid, consider the PGAR RAPID family.
The double thread format (2 × 90 cm) is designed for high-volume departments: it reduces the number of envelopes opened per session and improves profitability per unit. The undyed version offers maximum discretion on the surgical field; if you need greater visibility, request the same configuration in dyed thread on demand. Single-use sterile product: store in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions, volume orders or equivalents from other manufacturers, contact the technical-commercial team of Cahnos.





Reviews