Description
1. Commercial Introduction
The multifilament absorbable suture PREMISUT RAPID made of Polyglactin 910 (PGLAR) is the reference choice for B2B supply to operating theatres, day hospitals, outpatient minor surgery services, ophthalmology clinics and purchasing centres that need a synthetic reabsorbable thread with predictable behaviour, excellent handling and early loss of resistance.
This configuration combines a ⅜ circle needle with a 19 mm reverse cutting triangular body and point (DS19 profile), USP 4/0 gauge and a 75 cm colourless grooved thread: a highly valued combination for approximating fine tissues, ligating small-calibre vessels and ophthalmic surgery, where the needle passage must be clean and without tearing. It is presented in a box of 12 sterile units with batch traceability and an excellent quality-price ratio for hospital replenishment, tenders and continuous supply contracts.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a coating and grooved finish that favours thread sliding, smooth handling and firm, secure knot tying.
In its RAPID variant (low molecular weight polyglactin 910), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days: it retains approximately 50% of the initial tensile strength at 5 days and loses it completely at 14 days. This profile makes it suitable for superficial tissues and temporary approximations where removal of the material is not required.
The ⅜ circle needle with a 19 mm reverse cutting triangular body and point (reverse cutting) directs the cutting edge away from the wound: it creates a clean entry hole that preserves the skin edge and prevents the cut from widening in the puncture bed, ideal for skin, mucous membranes and firm thin tissues. The colourless thread offers maximum discretion on the surgical field. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. 2L22DS1940 · SKU AM2L22DS1940)
| Parameter | Specification |
|---|---|
| Thread material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Range | PREMISUT RAPID |
| Gauge | USP 4/0 (metric 1.5; approximate diameter 0.15 – 0.199 mm according to Pharmacopoeia) |
| Thread length | 75 cm |
| Thread colour | Colourless (undyed) |
| Needle shape | ⅜ circle (3/8, 135°) |
| Needle body and point | Triangular, reverse cutting, DS19 size (19 mm) |
| Swaged | 1 needle / 1 suture per unit |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Retained tensile strength (5 days) | 50 % |
| Retained tensile strength (14 days) | 0 % |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Absorption profile and tensile strength retention
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
3.3. Gauge equivalence (USP Pharmacopoeia)
| USP size | Metric size | Approximate diameter |
|---|---|---|
| 4/0 (this product) | 1.5 | 0.15 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread category of braided multifilament absorbable in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line from Ethicon (Johnson & Johnson MedTech), with which it shares composition, hydrolysis absorption mechanism and accelerated resistance loss profile. This reference shares material, USP 4/0 gauge, ⅜ circle curvature, 19 mm reverse cutting needle, colourless thread and 75 cm armed length with the following references, whose codes and attributes have been verified in the manufacturer’s official catalogue and authorised distribution:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | W9922 – USP 4/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 75 cm | Comparable by category (not interchangeable 1:1) | Almost total match of attributes: same material and rapid absorption profile, USP 4/0 gauge, ⅜ circle curvature, 19 mm reverse cutting needle, colourless thread and 75 cm length. They differ in the needle profile nomenclature (DS vs PS-2) and the braid coating. Code verified in Ethicon EMEA catalogue and authorised distribution (box of 12 units). |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VR496 – USP 4/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 45 cm | Comparable by category (not interchangeable 1:1) | Same needle and gauge configuration (4/0, 19 mm, ⅜ circle, reverse cutting) but 45 cm thread instead of 75 cm. |
| B. Braun / Aesculap | Safil Quick (low molecular weight polyglycolic acid, braided and coated) | C0046629 – USP 4/0, ⅜ circle reverse cutting needle with micro-point (DSMP) of 19 mm, undyed thread of 45 cm | Comparable by category (not interchangeable 1:1) | Same USP 4/0 gauge, ⅜ circle curvature and 19 mm reverse cutting needle; the base material differs (polyglycolic acid vs polyglactin 910), the needle profile (DSMP vs DS) and the thread length (45 cm vs 75 cm). |
Homologous ranges in the rapid absorption segment also include Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category in terms of material and absorption profile; for the exact combination USP 4/0 / DS19 mm needle / 75 cm thread, their specific codes must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tenders, verifying in each official datasheet the USP 4/0 gauge (metric 1.5), the ⅜ circle curvature, the needle type and size (19 mm reverse cutting triangular), the thread length (75 cm) and the colourless colour.
5. Selection tips and variants of interest
The USP 4/0 gauge (metric 1.5) is a common choice in fine skin, mucous membranes, paediatrics and fast-healing tissues where an optimal balance between strength and fineness is required: conjunctival suture in ophthalmology, approximation of mucous membranes, subcutaneous tissue and ligation of small-calibre vessels. The 19 mm ⅜ circle reverse cutting needle is especially recommended when a firm and precise passage through the skin or mucous membranes is required without tearing the edge.
Within the same PGLAR Polyglactin 910 RAPID range, Cahnos offers complementary configurations to adjust the reference to the protocol:
| SKU | Variant |
|---|---|
| AM2L22DS1940 (2L22DS1940) | PGLAR RAPID, DS19 reverse cutting needle, USP 4/0, colourless, 75 cm (this product) |
| AMP2L22DS1940 (P2L22DS1940) | PGLAR RAPID Prime, same needle and gauge, USP 4/0, colourless, 75 cm (Prime range) |
| AM2L22DS1930 (2L22DS1930) | PGLAR RAPID, same needle, USP 3/0, colourless, 75 cm |
| AMP2L21DS1940FN (P2L21DS1940FN) | PGLAR RAPID Prime, DS19 needle, USP 4/0, colourless, 45 cm, fine profile (FN) |
| AMP2L22XDS1940 (P2L22XDS1940) | PGLAR RAPID Prime, XDS19 precision needle with square body, USP 4/0, colourless, 75 cm |
| AMP2L22DS2630 (P2L22DS2630) | PGLAR RAPID Prime, DS26 needle, USP 3/0, colourless, 75 cm (longer needle) |
If your protocol prefers a longer tensile support (56–72 days), consider the standard PGLAR Polyglactin 910 range. The colourless version offers maximum aesthetic discretion; if greater visibility is required, request the same configuration in dyed colour on demand. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.