We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID | Needle ⅜ Circle Body and Triangular Point Reverse Cutting DS24 (24 mm) · USP 3/0 (Metric 2) · Colourless Fluted Thread 2 x 75 cm | PREMISUT RAPID Prime · Box of 12 units (Ref. P2L22DS2430.2)

84,84 €

Absorbable multifilament suture PREMISUT RAPID Prime (PGLAR, Polyglactin 910) with a ⅜ circle body needle and triangular point with reverse cutting of 24 mm (DS24), USP gauge 3/0 (metric 2) and colourless fluted thread in double format 2 x 75 cm. Rapid and predictable absorption by hydrolysis in 40–45 days, with tensile strength retention of 50% at 5 days and 0% at 14 days: ideal short-term support for skin, mucous membranes and fast-healing superficial tissues, without suture removal. Sterilised by gamma radiation, single-use and minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Factory ref. P2L22DS2430.2 · Price per box of 12 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS2430.2

Description

1. Commercial Introduction

The PGLAR (Polyglactin 910) absorbable multifilament suture in the RAPID variant and Prime quality from the PREMISUT RAPID range is the reference for accelerated-absorption surgical closure for general and ambulatory surgery operating theatres, emergency departments, ophthalmology clinics and B2B purchasing centres that need a braided, flexible thread with early and fully predictable strength loss.

Its ⅜ circle 24 mm needle with triangular body and reverse cutting point (DS24) penetrates firm, non-compliant tissues with a clean, controlled passage without tearing the edge, while the undyed thread in double 2 x 75 cm format offers maximum discretion on the surgical field and greater yield per pack. Practical and cost-effective presentation in a box of 12 units, with batch traceability and factory reference P2L22DS2430.2.

2. Technical explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a coated braided multifilament structure with a grooved finish that favours thread sliding, very smooth handling and a firm, secure knot, even in fine gauges such as USP 3/0.

In the RAPID variant (low molecular weight polyglactin 910), absorption occurs by hydrolysis over a period of 40 to 45 days, retaining 50% of the initial tensile strength at 5 days and losing it completely at 14 days. This profile makes it especially suitable for superficial fast-healing tissues (skin closure, mucosa, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suturing in ophthalmic surgery, in many cases without the need to remove the material.

The ⅜ circle needle (135°) with triangular body and reverse cutting point passes through firm tissues with precise entry and exit, minimising trauma and edge tearing. Sterile product by gamma radiation, single-use and non-reesterilizable: check the integrity of the packaging and the expiry date before each procedure.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS2430.2 · SKU AMP2L22DS2430.2)

Parameter Specification
Material Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant
Thread structure Braided coated multifilament, fluted finish
Quality Prime (range PREMISUT RAPID Prime)
Gauge USP 3/0 (metric 2; approximate diameter 0.20 – 0.249 mm according to Pharmacopoeia)
Thread colour Colourless
Thread length 2 x 75 cm (double format)
Needle shape ⅜ circle (3/8, 135°)
Needle body and point Triangular reverse cutting (reverse cutting), size DS24 (24 mm)
Absorption mechanism Hydrolysis
Absorption period 40 – 45 days
Tensile strength retention 50 % at 5 days / 0 % at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Factory reference P2L22DS2430.2
SKU Cahnos AMP2L22DS2430.2

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Complete absorption 40 – 45 days by hydrolysis (predictable and uniform rate)

Absorption by hydrolysis with minimal tissue reaction, excellent initial tensile strength and optimal knot tying, with a fully predictable absorption rate.

3.3. Size equivalence

USP size Metric size Approximate diameter
3/0 2 0.20 – 0.249 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Fast-absorbing polyglactin 910 (low molecular weight) is the most widespread fast-acting braided multifilament absorbable category in the surgical market, whose international clinical benchmark is the VICRYL RAPIDE line from Ethicon (J&J MedTech). This reference shares material, accelerated absorption profile (≈42 days), tensile strength retention (≈50% at 5 days / 0% at 14 days), USP 3/0 gauge, ⅜ circle curvature, reverse cutting point, undyed thread and 75 cm length with the following verified codes:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) W9932 – USP 3/0, PS Prime 26 mm needle in ⅜ circle, reverse cutting point, undyed 75 cm thread, box of 12 Comparable by category (not interchangeable 1:1) Almost total match of attributes: same material and fast absorption (≈42 days), USP 3/0 gauge (metric 2), ⅜ curvature, reverse cutting point, undyed 75 cm thread and box of 12; the needle size (26 mm PS vs. 24 mm DS24) and the format (single thread vs. double 2 x 75 cm) differ. Code confirmed in the official Ethicon EMEA catalogue and authorised distributors.
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (braided polyglactin 910, colourless) VR2252 – USP 3/0, FS-1 24 mm needle in ⅜ circle, reverse cutting point, undyed 75 cm thread Comparable by category (not interchangeable 1:1) Same material, fast absorption, USP 3/0 gauge, 24 mm needle size (FS-1) and reverse cutting point identical to DS24; the format (single 75 cm thread vs. double 2 x 75 cm) and the needle nomenclature (FS-1 vs. DS24) differ. Code confirmed in the Ethicon EMEA catalogue and European distributors.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders, verifying in each official datasheet the USP 3/0 gauge (metric 2), the ⅜ circle curvature, the needle type and size (24 mm reverse cutting triangular), the thread length (75 cm), the undyed colour and the double 2 x 75 cm format. Comparable ranges in the fast-absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable by category in terms of material and absorption profile, although their specific codes for this exact combination (USP 3/0 / DS24 reverse cutting needle / double 75 cm thread) must be confirmed with each manufacturer. Standard VICRYL (56 – 72 day absorption) is not equivalent to this RAPID version.

5. Selection tips and variants of interest

The USP 3/0 gauge (metric 2) with a ⅜ circle reverse cutting triangular point needle offers an ideal balance between initial strength and handling, indicated for skin closure, subcutaneous tissue, mucosa, approximation of soft tissues, ligation of small-calibre vessels and ophthalmic surgery. The double 2 x 75 cm format maximises yield per pack and reduces the number of replacements in the operating theatre.

Within the same PGLAR Polyglactin 910 RAPID Prime range, Cahnos offers complementary configurations: AMP2L22DS2430 (same DS24 needle and USP 3/0 gauge, but in single 75 cm thread), AMP2L22DS2630.2 (USP 3/0 with DS26 needle and double 2 x 75 cm format), AMP2L22DS2630 (DS26 needle, single 75 cm thread) and AMP2L22DS2420.2 (USP 2/0, larger gauge, DS24 needle and double format). For a longer tensile support profile, consider the PGLA family of standard polyglactin 910 (56 – 72 day absorption, ref. P1L22DS2430) or the PGA family of fast polyglycolic acid (ref. AMP222DS2430). The undyed version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand.

Sterile single-use product: store in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each procedure. All references are supplied in boxes of 12 units. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, low molecular weight RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Quality

Prime (PREMISUT RAPID Prime)

Gauge

USP 3/0 (metric 2)

Thread diameter

0.20 – 0.249 mm

Needle shape

3/8 circle (135°)

Tip type

Triangular reverse cutting (reverse cutting)

Needle size

DS24 (24 mm)

Tensile strength retention

50 % at 5 days / 0 % at 14 days

Sterilisation

Gamma radiation

Use

Single-use, not re-sterilisable

Presentation

Box of 12 units

Manufacturer reference

P2L22DS2430.2

Indications

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

DS 24

Usp

3/0

Color

Colourless

Medida de hilo

2 × 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID | Needle ⅜ Circle Body and Triangular Point Reverse Cutting DS24 (24 mm) · USP 3/0 (Metric 2) · Colourless Fluted Thread 2 x 75 cm | PREMISUT RAPID Prime · Box of 12 units (Ref. P2L22DS2430.2)”

Your email address will not be published. Required fields are marked *