We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Poliglactina 910 RAPID Prime · Needle 3/8 Circle Triangular Reverse Cutting DS 19 mm · USP 5/0 (Metric 1) · Colourless · 75 cm · Box of 12 units · Ref. P2L22DS1950

Original price was: 44,86 €.Current price is: 34,80 €.

Absorbable multifilament suture PGLAR Poliglactina 910 RAPID in Prime quality (PREMISUT RAPID range), with a ⅜ circle body needle and triangular point with reverse cutting edge of 19 mm (DS19 profile), USP 5/0 (metric 1) gauge and 75 cm colourless grooved thread. Accelerated and predictable absorption by hydrolysis in 40–45 days: retains 50 % of the initial tensile strength at 5 days and loses it completely at 14 days, making it the ideal choice for fast-healing tissues. Sterilised by gamma radiation, single-use and with minimal tissue reaction; indicated for approximation of fine tissues, ligatures and ophthalmic surgery. Presentation in a box of 12 units; minimum order of 30 boxes for the B2B channel. Factory ref. P2L22DS1950 · SKU AMP2L22DS1950.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L22DS1950

Description

1. Commercial Introduction

The Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID in Prime quality (PREMISUT RAPID range) is the reference for accelerated absorption surgical closure for hospitals, general and dermatological surgery operating theatres, emergency departments, ophthalmology clinics and B2B purchasing centres that need a braided, flexible thread with a totally predictable early loss of strength.

Its ⅜ circle needle with a reverse cutting triangular body and point of 19 mm ensures clean and controlled penetration in skin and firm tissues, while the undyed grooved thread of 75 cm offers maximum discretion on the surgical field. A practical and cost-effective presentation, in a box of 12 sterile units, designed for rapidly healing tissues.

2. Technical Explanation

Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure coated with a grooved finish that favours thread sliding, smooth handling and a firm, secure knot.

In the RAPID variant (low molecular weight), the thread is formulated to lose tensile strength in an accelerated and programmed manner: it retains 50 % of the initial resistance at 5 days and 0 % at 14 days, with complete absorption by hydrolysis between 40 and 45 days. This profile makes it especially suitable for superficial tissues with rapid healing (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture in ophthalmic surgery, where prolonged tensile support or material removal is not required.

The reverse cutting needle (reverse cutting) orients the cutting edge away from the wound, generating a clean entry hole that preserves the skin edge and prevents the cut from widening in the puncture bed. Sterile single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. P2L22DS1950 · SKU AMP2L22DS1950)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant
Thread structure Braided coated multifilament, fluted finish
Quality Prime (PREMISUT RAPID range)
Gauge USP 5/0 (metric 1)
Thread diameter 0.10 – 0.149 mm (approximate, according to Pharmacopoeia)
Thread colour Colourless
Thread length 75 cm
Needle shape 3/8 circle (135°)
Needle body and point Triangular, reverse cutting
Needle size 19 mm (DS19)
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Tissue approximation, ligatures and ophthalmic surgery
Commercial format Box of 12 units (minimum order 30 boxes)

3.2. Absorption profile and tensile strength retention

Parameter Value
Absorption type Hydrolysis
Absorption time 40 – 45 days
Tensile strength at 5 days 50% of initial strength
Tensile strength at 14 days 0% (total loss of tensile support)
Absorption rate Predictable and uniform

3.3. Size equivalence

USP size Metric size Approximate diameter
5/0 1 0.10 – 0.149 mm (approximate, according to Pharmacopoeia)

4. Equivalences and Cross-References

Rapid absorption polyglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market, whose international clinical reference is the VICRYL RAPIDE line from Ethicon. This reference shares material, USP 5/0 gauge, undyed braided thread of 75 cm and rapid absorption profile with the homologous lines in the sector. Only codes whose attributes have been verified in official catalogues and authorised distributors are included; none of these references should be considered interchangeable 1:1 without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) VR2296 – USP 5/0, FS-3 needle (⅜ circle, reverse cutting), 75 cm Comparable by category (not interchangeable 1:1) Same material and accelerated absorption (≈50 % at 5 days), USP 5/0 gauge, undyed braided thread of 75 cm and ⅜ circle reverse cutting needle. The nomenclature and exact geometry of the needle differ (FS-3 versus DS19 of 19 mm), the coating of the braid and the commercial house. Code verified in authorised distributors; check the official data sheet before substituting.
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) W9969 – USP 5/0, RB-1 needle (taper point), 75 cm, undyed Comparable by category (not interchangeable 1:1) Same material, USP 5/0 gauge, undyed colour and length of 75 cm; the needle point differs (taper with cylindrical body versus triangular reverse cutting). Not recommended as a substitute if the protocol requires a cutting needle. Code verified in official catalogue and authorised distributors.

There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; consult the technical department before using in tenders.

As homologous ranges in the rapid absorption segment, Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) appear, comparable by category by material and absorption profile, although for the exact combination USP 5/0 / DS19 needle / 75 cm their specific codes must be confirmed with the manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.

5. Selection tips and variants of interest

The USP 5/0 gauge (metric 1) is ideal for fine and delicate tissues: skin, mucous membranes, conjunctiva, ophthalmic surgery, paediatric surgery and superficial approximations where maximum fineness is required with short-term support. The ⅜ circle reverse cutting needle of 19 mm is especially recommended when a firm and clean passage through the skin or mucous membranes is needed without tearing the edge, typical in dermatology, minor surgery and ophthalmology.

Within the same PGLAR Polyglactin 910 RAPID family with DS19 triangular needle, Cahnos offers complementary gauges: USP 3/0 (SKU AMP2L22DS1930) and USP 4/0 (SKU AMP2L22DS1940) in Prime quality, as well as the same 5/0 configuration in standard quality (SKU AM2L22DS1950). For smaller needle sizes, the DS16 variant is available in USP 3/0 and 5/0 gauges (SKU AMP2L22DS1630 and AMP2L22DS1650). If the protocol prefers a precision reverse cutting point with a square body, consider the XDS19 range; if a taper point for looser tissues is preferred, the HR family. The undyed version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand.

Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure and store it in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders (minimum 30 boxes) or equivalents from other commercial brands, contact the technical-commercial team of Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide), RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Quality

Prime (PREMISUT RAPID range)

USP size

5/0 (metric 1)

Thread diameter

0.10 – 0.149 mm (approximate, according to Pharmacopoeia)

Needle shape

3/8 circle (135°)

Needle tip

Triangular, reverse cutting (reverse cutting), body and point

Needle size

19 mm (DS19)

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Tissue reaction

Minimal, with excellent tensile strength and knot tying

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units (minimum order 30 boxes)

Manufacturer reference

P2L22DS1950

Medida de aguja

DS 19

Usp

5/0

Color

Colourless

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Poliglactina 910 RAPID Prime · Needle 3/8 Circle Triangular Reverse Cutting DS 19 mm · USP 5/0 (Metric 1) · Colourless · 75 cm · Box of 12 units · Ref. P2L22DS1950”

Your email address will not be published. Required fields are marked *