Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID Prime of Polyglactin 910 (PGLAR) is the reference for accelerated absorption surgical closure for operating theatres of general and day surgery, emergency departments, ophthalmology clinics and B2B purchasing centres that need a braided, flexible thread with early and totally predictable loss of strength. Its ⅜ circle 30 mm needle with reverse cutting triangular body and point (DS30) perforates firm, non-compliant tissues with a clean, controlled pass, without tearing the skin edge, while the 75 cm colourless thread offers maximum discretion on the surgical field. It is presented in a box of 12 sterile units with batch traceability and factory reference P2L22DS3020, optimising institutional stock management and cost per procedure.
2. Technical explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure with a grooved finish that favours thread glide, very soft handling and a firm, secure knot, even in medium gauges such as USP 2/0. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis — a predictable process independent of the patient’s enzymatic activity — within 40 to 45 days: it retains approximately 50 % of initial tensile strength at 5 days and loses it completely by 14 days. This profile makes it especially suitable for fast-healing superficial tissues (skin closure, mucous membranes, subcutaneous tissue), ligation of small-calibre vessels and conjunctival suture, in many cases without the need to remove the material.
The ⅜ circle needle (135°) with reverse cutting triangular body and point (reverse cutting) directs the cutting edge away from the wound, creating a clean entry orifice that preserves the skin edge; the Prime quality incorporates an atraumatic silicone-free needle for a cleaner pass and less tissue damage. The product is sterilised by gamma radiation, is single-use and non-reesterilisable: check the integrity of the packaging and the expiry date before each procedure.
3. Technical Specifications
3.1. General characteristics (Ref. P2L22DS3020 · SKU AMP2L22DS3020)
| Parameter | Specification |
| Material | Polyglactin 910 (PGLAR): copolymer 90% glycolide / 10% L-lactide, RAPID low molecular weight variant |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 2/0 (metric 3; approximate diameter 0.30 – 0.339 mm according to Pharmacopoeia) |
| Thread colour | Colourless (undyed) |
| Thread length | 75 cm |
| Needle shape | ⅜ circle (3/8, 135°) |
| Needle body and point | Triangular reverse cutting (reverse cutting), body and point |
| Needle size | DS30 (30 mm) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Factory reference | P2L22DS3020 |
| SKU Cahnos | AMP2L22DS3020 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Complete absorption | 40 – 45 days by hydrolysis (predictable and uniform rate) |
Profile corresponding to the RAPID formulation; not to be confused with standard polyglactin 910 (PGLA line, absorption 56 – 72 days).
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 2/0 | 3 | 0.30 – 0.339 mm (indicative, according to Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable in the surgical market, whose international clinical reference is the Coated VICRYL RAPIDE line from Ethicon (Johnson \u0026 Johnson MedTech), which shares composition (90 % glycolide / 10 % L-lactide), braided structure, colourless colour and accelerated absorption profile (loss of strength at 10-14 days and complete absorption around 42 days). Comparable ranges in the rapid absorption segment include Safil Quick and Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH), Surgicryl Fast Absorb (SMI) and AssuCryl (Assut Medical), comparable by category, material and absorption profile.
A cross-reference table with codes from other manufacturers is not included because for the exact configuration of this data sheet (USP 2/0 gauge, ⅜ circle reverse cutting needle 30 mm, Prime quality, colourless grooved thread 75 cm) it has not been possible to verify in an official catalogue a code from another brand that simultaneously meets all attributes within tolerance: the EMEA catalogue of Coated VICRYL RAPIDE does not include a 30 mm needle in ⅜ circle reverse cutting for gauge 2/0 (its reverse cutting needles in this gauge are 16, 19, 24 and 26 mm), and the specific codes from the other manufacturers are pending confirmation with each manufacturer.
There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender, verifying in each official data sheet the USP 2/0 gauge (metric 3), the ⅜ circle curvature, the type and size of needle (30 mm reverse cutting triangular), the attachment (without double needle), the thread length (75 cm) and the colourless colour. Standard VICRYL (absorption 56 – 72 days) is not comparable to this RAPID version due to its longer strength retention profile.
5. Selection tips and variants of interest
The USP 2/0 gauge (metric 3) with a 30 mm ⅜ circle reverse cutting triangular point needle offers an ideal balance between initial strength and manageability, indicated for skin closure, subcutaneous tissue, mucous membranes, soft tissue approximation, ligation of small-calibre vessels and ophthalmic surgery, with early loss of strength that in many indications avoids the removal of stitches. Always verify three parameters on the surgical report: USP gauge, needle geometry and size, and thread length.
Within the same PGLAR Poliglactina 910 RAPID Prime range with reverse cutting needle DS, Cahnos offers complementary configurations: the same DS30 needle in Normal quality (SKU AM2L22DS3020), the DS30 needle in USP 0 gauge with 90 cm thread (SKU AMP2L23DS3010), the DS19 needle in USP 3/0 (SKU AMP2L22DS1930) for finer areas, the DS36 needle in USP 2/0 (SKU AMP2L22DS3620) and its double-thread format 2 × 75 cm (SKU AMP2L22DS3620.2) for high-volume services. If your protocol prefers a conical tip (taperpoint), please refer to the HR family; and if you require a longer tensile support profile, consider the standard PGLA family of poliglactina 910 (absorption 56 – 72 days).
The colourless version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand. Sterile single-use product: store in a cool, dry place, protected from sunlight, and check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions, volume orders or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.