Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR Polyglactin 910 RAPID from the PREMISUT range is the technical choice when the procedure requires short-term wound support, predictable absorption and excellent tissue handling. Its ½ circle 36 mm needle with trocar point (Tapercut) combines the ease of penetration of a conical point with the ability to pass through fibrous and dense tissues without tearing, minimising tissue trauma. Supplied in a box of 12 units, it is a reliable and sterile solution for operating theatres, day hospitals, ambulatory surgery, ophthalmology and hospital supply contracts.
2. Technical explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided grooved multifilament structure that provides flexibility, smooth passage through tissues and a firm, secure knot. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis in 40–45 days, retaining approximately 50% of the initial tensile strength at 5 days and losing it completely at 14 days; this makes it suitable for superficial tissues, mucous membranes and temporary approximation of soft tissues where material removal is not required.
The ½ circle needle with cylindrical body and trocar point (HRT36 profile) combines the strength of a round body with a sharp point that penetrates dense tissues without aggressive cutting effect. The colourless grooved thread facilitates handling and firm knotting. Gamma radiation sterilisation guarantees final sterility with minimal alteration of the material’s mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
| Material | Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament, grooved |
| Family / version | PGLAR – RAPID (rapid absorption), standard quality |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle | ½ circle, cylindrical body, 36 mm (HRT36) |
| Needle tip | Trocar / Tapercut |
| Absorption | By hydrolysis, 40–45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Factory reference | 2L22HRT3620 |
| Commercial format | Box of 12 units (minimum order 30 boxes) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread absorbable multifilament category in the surgical market. This reference shares material, USP 2/0 gauge, ½ circle curvature, cylindrical needle with 36 mm trocar point, colourless thread and rapid absorption profile with the homologous line of the sector’s leading manufacturer. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | VR945 (EMEA: family V9450H) | Comparable by category (not interchangeable 1:1) | Same material and rapid absorption (±42 days), USP 2/0 gauge, colourless braided thread and ½ circle 36 mm needle with Tapercut point (CT-1) match in dimensions. They differ in thread length (90 cm / 36” in Ethicon versus 75 cm), needle nomenclature (CT-1 versus HRT36) and the braid coating. Code confirmed in Ethicon’s official catalogue and authorised distributors. |
Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; they are not included in the table because no verified code is available for the exact combination USP 2/0 / 36 mm needle / Tapercut trocar point / 75 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.
5. Selection tips and variants of interest
USP 2/0 gauge (metric 3) offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small and medium-calibre vessels. The trocar point needle (Tapercut) is especially recommended when it is necessary to pass through somewhat firmer tissues than with a conventional conical point, without the cutting effect of triangular needles.
Within the same PGLAR RAPID range with HRT36 needle, Cahnos offers complementary configurations: the version with 90 cm thread (SKU AM2L23HRT3620) and USP 0 gauge with 75 cm thread (SKU AM2L22HRT3610). If a taperpoint conical point is preferred in the same gauge and length, consult the HR36 family (SKU AM2L22HR3620); and if the tissue is firm and reverse cutting is required, consider the triangular variant of the equivalent family. The colourless version offers maximum discretion in the field; if greater visibility is required, consider the same configuration in violet on demand. Check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions or volume orders, contact the technical-commercial team at Cahnos.





Reviews