Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR of poliglactina 910 RAPID in Prime quality (range PREMISUT RAPID) is a high-performance surgical reference designed for the professional B2B channel: hospitals, clinics, purchasing centres and surgical services that need a braided, flexible thread with early, predictable and documented loss of strength.
It is presented mounted with a ½ circle needle with cylindrical body and trocar point (tapercut) of 40 mm (HRT 40), USP 1 gauge and 90 cm colourless grooved thread, in a box of 12 units. The trocar point offers firmer penetration in slightly denser or fibrous tissues than a conventional conical point, maintaining the precision of a cylindrical body and without enlarging the exit hole. It is the usual choice for approximation of skin and mucous membranes, ligatures, episiotomies and ophthalmic surgery.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. In its RAPID variant (low molecular weight), the loss of strength and mass is accelerated compared to conventional polyglactin 910: absorption occurs by hydrolysis, that is, by chemical degradation of the polymer in contact with tissue fluids, over a predictable period of 40 to 45 days and with minimal tissue reaction.
The tensile strength retention profile is 50% at 5 days and 0% at 14 days, so it is especially indicated for tissues that only require short-term support (7-10 days of wound support). Its braided multifilament structure with grooved finish and coating provides very smooth handling, controlled sliding and firm, secure knot tying. The product is supplied sterile by gamma radiation, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics (Ref. P2L23HRT4001)
| Parameter | Specification |
| Thread material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Gauge | USP 1 (metric 4, approximate diameter 0.40–0.499 mm) |
| Thread colour | Colourless |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Trocar (tapercut) |
| Needle size | HRT 40 mm |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Quality | Prime (PREMISUT RAPID range) |
| Presentation | Box of 12 sterile units |
| Minimum order | 30 boxes |
| Factory reference | P2L23HRT4001 |
| SKU Cahnos | AMP2L23HRT4001 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 1 | 4 | 0.40 – 0.499 mm (indicative, according to Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widespread synthetic absorbable materials with rapid absorption in the surgical market. The analysed reference is comparable at category level with braided polyglactin 910 RAPID sutures from other manufacturers, both in composition and in absorption profile (≈42 days) and tension retention (≈50% at 5 days). Only the reference whose attributes have been verified in the manufacturer’s official catalogue and authorised distributors is included:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE – braided polyglactin 910 with rapid absorption, colourless, ½ circle tapercut needle | W9964 | Comparable by category (not interchangeable 1:1) | Same composition (90% glycolide / 10% L-lactide), same USP 1 gauge, 90 cm colourless thread, ½ circle curvature and tapercut point; the needle size differs: tapercut of 36 mm (V-34) compared to HRT 40 mm of this reference. Code confirmed in the official Ethicon EMEA catalogue and authorised distributors. |
As homologous reference ranges in the sector, the braided rapid-absorption polyglactin 910 sutures from B. Braun (Safil Quick / NOVOSYN QUICK lines), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) are listed, whose specific codes for the exact combination USP 1 / 40 mm trocar needle / 90 cm thread must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
There is no equivalence table validated by the manufacturer; consult the technical department before using in tendering.
5. Selection tips and variants of interest
Before ordering, verify three parameters: the USP gauge (USP 1 / metric 4 is reserved for tissues requiring intermediate initial strength: skin, subcutaneous tissue, mucosa and approximation of soft tissues), the needle geometry (the ½ circle with trocar point is recommended when firmer penetration is required in somewhat denser tissues, while the conical point is the most common in lax tissues) and the thread length (90 cm, ideal for general surgery and material replenishment).
Within the same PGLAR RAPID Prime range with trocar point you will find complementary configurations: the HRT 40 variant in standard quality (ref. AM2L23HRT4001), the HRT 40 in USP 2/0 gauge (ref. AMP2L23HRT4020), the HRT 36 in USP 2/0 (ref. AM2L23HRT3620) and the HRT 48 in USP 2 (ref. AMP2L23HRT4802). If the protocol prefers a taperpoint conical point in similar gauges, consult the HR family (ref. AMP2L23HRP4010 / AMP2L23HRP4810); and if the tissue is firm and reverse cutting is required, consider the triangular HS variant (ref. AMP2L23HS4010).
The colourless version offers maximum discretion in the field; if greater visibility is required, consider the same configuration in thread dyed on demand. As it is a sterile single-use product, check the integrity of the packaging and the expiry date before each intervention and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions or volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.