Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR Polyglactin 910 RAPID in Prime quality is the reference surgical closure solution when the procedure requires short-term wound support, fully predictable resorption and exceptional tissue handling. It features a ½ circle needle with cylindrical body and Taperpoint conical tip of 26 mm (HR26) that penetrates soft tissues with atraumatic passage, a quality especially valued in ophthalmic surgery, ligation of small-calibre vessels and tissue approximation. Designed for B2B supply to operating theatres, general surgery and ophthalmology departments, it is presented in a box of 12 individually packaged, sterile, single-use units.
2. Technical Explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure with a crimped finish and lubricant coating, providing smooth passage through tissue, excellent handling and secure, reliable knot tying. In the RAPID variant, the polymer has a low molecular weight and accelerates loss of strength and mass: it retains 50 % of the initial tensile strength at 5 days and loses all strength at 14 days, with complete absorption by hydrolysis between 40 and 45 days and minimal tissue reaction.
The ½ circle needle (160°) with cylindrical body and crimped Taperpoint conical tip of 26 mm separates tissue fibres rather than cutting them, minimising trauma and bleeding at the entry point. The undyed thread offers maximum discretion on the surgical field, a quality especially appreciated in ophthalmic surgery. Sterilisation by gamma radiation guarantees the final sterility of the product; it is single-use and does not allow re-sterilisation.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Factory reference | P2L22HR2620 |
| SKU Cahnos | AMP2L22HR2620 |
| Brand / Quality | PREMISUT RAPID – PGLAR Prime |
| Material | Polyglactin 910 (copolymer 90 % glycolide / 10 % low molecular weight L-lactide) |
| Thread structure | Braided coated multifilament, fluted finish |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless |
| Thread length | 75 cm |
| Needle shape | ½ circle (1/2, 160°), cylindrical body |
| Needle tip | Conical grooved (Taperpoint) |
| Needle size | 26 mm (HR 26) |
| Absorption mechanism | Hydrolysis (40 – 45 days) |
| Sterilisation | Gamma radiation; sterile, single-use, non-resterilizable |
| Tissue reaction | Minimal; excellent tensile strength and knot security |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40 – 45 days by hydrolysis, predictable and uniform rate |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widely used short-acting braided absorbable suture category on the market. The international clinical reference is the VICRYL RAPIDE line from Ethicon (J&J MedTech), with which this reference shares composition, accelerated strength loss profile, ½ circle curvature, conical needle, USP 2/0 gauge and undyed 75 cm thread. Only codes whose attributes have been verified in public sources and authorised distributors are included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided poliglactin 910, undyed), MH-1 ½ circle needle with conical point 31 mm, 75 cm | W9975 (EMEA) | Comparable by category (not interchangeable 1:1) | Same material, rapid absorption (≈42 days), USP 2/0 gauge (metric 3), ½ circle curvature, conical tip and undyed braided 75 cm thread. They differ in needle size (MH-1 of 31 mm vs HR 26 mm), the exact needle design and the packaging format. Code confirmed in Ethicon EMEA catalogue and authorised distributors. |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided poliglactin 910, undyed), PS 3/8 circle needle with reverse cutting point 26 mm, 75 cm | W9933 (EMEA) | Comparable by category (not interchangeable 1:1) | Shares material, rapid absorption (wound support 7-10 days), USP 2/0 gauge, 26 mm needle and undyed 75 cm thread. They differ in curvature (3/8 circle vs ½ circle) and tip (reverse cutting vs Taperpoint conical). Code confirmed in Ethicon EMEA catalogue and several authorised distributors. |
Among the homologous families of rapid-absorption polyglactin 910 without a verified cross-reference code for this exact configuration are Safil Quick and Novosyn Quick (B. Braun), Surgicryl Fast Absorb (SMI) and DemeCRYL Fast (DemeTECH); in all cases, gauge, tip geometry, needle size and thread length must be confirmed before any substitution. Standard VICRYL (absorption 56-72 days) is not comparable to the RAPID profile in terms of tensile strength retention. There is no manufacturer-validated equivalence table cross-referencing this product with other brands; consult the technical department before use in tenders, verifying in each official data sheet the USP 2/0 gauge (metric 3), ½ circle curvature, needle type and size (Taperpoint conical 26 mm), thread length (75 cm) and undyed colour.
5. Selection tips and variants of interest
The USP 2/0 gauge with Taperpoint conical 26 mm needle is a common choice for approximation of skin and mucous membranes, subcutaneous tissue, ligatures and ophthalmic surgery, with early strength loss that avoids suture removal in many indications. For tissues requiring short-term support (7-10 days) it is the ideal configuration; if the protocol requires a thicker or thinner gauge, in the same PGLAR RAPID range with cylindrical conical-tip needle you will find complementary references in Prime and standard quality, in needle sizes HR22, HR30 and HR40 and gauges from USP 4/0.
As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours, contact our technical-commercial team at Cahnos.





Reviews