We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle ½ Circle Cylindrical Conical Point (Taperpoint) HR36 mm · USP 2/0 (Metric 3) · Colourless 90 cm · Box 12 units · Ref. P2L23HR3620

Original price was: 46,08 €.Current price is: 34,80 €.

Absorbable multifilament suture PREMISUT RAPID of Polyglactin 910 (PGLAR) in Prime quality, with a ½ circle needle with cylindrical body and conical point (Taperpoint) of 36 mm (HR36). Gauge USP 2/0 (metric 3), colourless fluted thread of 90 cm, sterile by gamma radiation and single-use. Predictable absorption by hydrolysis in 40–45 days: retains 50% of tensile strength at 5 days and loses it at 14 days. Ideal for approximation of soft tissues, ligation of small and medium-calibre vessels and ophthalmic surgery. Factory reference P2L23HR3620 · Presentation in box of 12 units with a minimum order of 30 boxes for the B2B channel.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 unidades por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP2L23HR3620

Description

1. Commercial Introduction

The absorbable multifilament suture PGLAR of poliglactin 910 RAPID in Prime quality (range PREMISUT RAPID) is the reference surgical closure solution when the procedure requires short-term wound support, fully predictable resorption and excellent tissue handling. This presentation incorporates a colourless 90 cm thread mounted with a ½ circle 36 mm needle, cylindrical body and tapered point (Taperpoint), ensuring maximum discretion in the surgical field and an atraumatic passage through soft and well-perfused tissues.

Especially indicated for subcutaneous tissue, mucosa, approximation of delicate tissues, ligatures of small and medium-calibre vessels and ophthalmic surgery. Presented in a box of 12 sterile units, it is a reliable and cost-effective option for operating theatres, day hospitals, ambulatory surgery, ophthalmology services and hospital supply contracts, with a minimum order of 30 boxes. A solution with traceability, consistent quality and excellent value for money for purchasing centres.

2. Technical explanation

Poliglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish. This configuration provides flexibility, low shape memory, smooth passage through tissues and firm, secure knot tying.

In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within 40 to 45 days, retaining approximately 50% of the initial tensile strength at 5 days and losing it completely at 14 days. This makes it suitable for superficial tissues and temporary approximation of soft tissues where material removal is not required. The ½ circle needle with cylindrical body and tapered point (HR36 profile, Taperpoint) offers atraumatic penetration, separating fibres without tearing them. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics (Ref. P2L23HR3620 · SKU AMP2L23HR3620)

Parameter Specification
Material Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID)
Thread structure Braided coated multifilament, fluted finish
Family / version PGLAR – RAPID (rapid absorption), Prime quality (PREMISUT RAPID)
Gauge USP 2/0 (metric 3)
Thread diameter 0.30 – 0.339 mm (indicative, according to Pharmacopoeia)
Thread colour Colourless
Thread length 90 cm
Needle shape Half circle (1/2, 160°)
Needle body Cylindrical
Needle tip Conical / Taperpoint
Needle size HR 36 mm (Prime quality)
Absorption mechanism Hydrolysis, 40–45 days
Tensile strength 50% at 5 days; 0% at 14 days
Sterilisation Gamma radiation; single-use, not re-sterilisable
Tissue reaction Minimal, with excellent tensile strength and knot tying
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Factory reference P2L23HR3620
SKU Cahnos AMP2L23HR3620
Commercial format Box of 12 units (minimum order 30 boxes)

3.2. Tensile strength retention profile

Post-implantation time Retained tensile strength
5 days 50 % of initial tensile strength
14 days 0% (total loss of tensile support)
Total absorption 40–45 days, by hydrolysis (predictable and uniform rate)

The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption poliglactin 910 (PGLA line, 56–72 days), also available in our catalogue.

4. Equivalences and Cross-References

Rapid absorption poliglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market. This reference shares material, USP 2/0 gauge, ½ circle curvature, 36 mm cylindrical tapered-point needle, colourless 90 cm thread and rapid absorption profile with the homologous line of the sector’s leading manufacturer. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue and authorised distributors is included:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Ethicon (Johnson & Johnson MedTech) VICRYL RAPIDE (polyglactin 910, braided, colourless) V9450H (EMEA) Comparable by category (not interchangeable 1:1) They match: rapid absorption poliglactin 910 material (≈42 days), USP 2/0 gauge, ½ circle 36 mm needle with tapered point (CT-1 PLUS / Taperpoint) and colourless 90 cm thread. They differ: needle nomenclature (CT-1 PLUS vs. HR36 Prime), braid coating (calcium stearate) and packaging format. Code confirmed in Ethicon’s EMEA catalogue and authorised distributors.

Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; they are not included in the table because no verified code is available for the exact combination USP 2/0 / 36 mm needle / Taperpoint conical point / 90 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (56–72 day absorption) is not comparable to this RAPID version. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.

5. Selection tips and variants of interest

USP 2/0 gauge (metric 3) offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligatures of small and medium-calibre vessels. The cylindrical tapered-point needle (Taperpoint) is especially recommended for soft and well-perfused tissues, where an atraumatic passage without cutting effect is sought, including ophthalmic surgery.

Reference Variant
AMP2L23HR3620.2 PGLAR RAPID Prime USP 2/0, HR36 needle, colourless, 2 threads of 90 cm (double strand per pack)
AM2L23HR3620 PGLAR RAPID USP 2/0 (standard quality), HR36 needle, colourless, 90 cm
AMP2L22HR3620 PGLAR RAPID Prime USP 2/0, HR36 needle, colourless, 75 cm (shorter thread length)
AMP2L23HR3610 PGLAR RAPID Prime USP 0, HR36 needle, colourless, 90 cm (larger gauge)
AM2L23HRT3620 PGLAR RAPID USP 2/0, trocar point needle Tapercut HRT36, colourless, 90 cm (firmer tissues)
AM2L23HR3601 PGLAR RAPID USP 1, HR36 needle, colourless, 90 cm (higher strength)

All references are supplied in boxes of 12 units, with a minimum order of 30 boxes to ensure continuous supply to your healthcare facility. The colourless version offers maximum discretion in the surgical field; if greater visibility is required, consider the same configuration in violet on request. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight RAPID variant

Thread structure

Braided coated multifilament, fluted finish

Quality

Prime (PREMISUT RAPID range)

Gauge

USP 2/0 (metric 3)

Thread diameter

0.30 – 0.339 mm (indicative, according to Pharmacopoeia)

Needle shape

Half circle (1/2, 160°)

Needle body

Cylindrical

Needle tip

Conical / Taperpoint

Needle size

HR 36 mm (Prime quality)

Tensile strength

50% at 5 days; 0% at 14 days

Sterilisation

Gamma radiation; single-use, not re-sterilisable

Tissue reaction

Minimal, with excellent tensile strength and knot tying

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Manufacturer reference

P2L23HR3620

Presentation

Box of 12 units (minimum order 30 boxes)

Medida de aguja

HR 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Rapid absorbable (≤ 45 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLAR Polyglactin 910 RAPID Prime · Needle ½ Circle Cylindrical Conical Point (Taperpoint) HR36 mm · USP 2/0 (Metric 3) · Colourless 90 cm · Box 12 units · Ref. P2L23HR3620”

Your email address will not be published. Required fields are marked *