Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID Prime (polyglactin 910 – PGLAR) is the technical choice when the procedure requires short-term wound support with predictable resorption and excellent tissue handling. This presentation mounts a ½ circle needle with cylindrical body and conical Taperpoint point of 36 mm (HR 36), USP 1 gauge and 75 cm colourless grooved thread: a combination highly valued in general surgery, ligatures and ophthalmic surgery for its atraumatic passage and firm, secure knot.
Presented in a box of 12 sterile units, it is a reliable and cost-effective solution for operating theatres, day hospitals, ambulatory surgery and hospital supply contracts, with advantageous conditions for centralised replenishment (minimum order 30 boxes).
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure with a grooved finish and lubricating coating that favours thread sliding, smooth handling and firm knotting. In its RAPID variant (low molecular weight), absorption occurs by hydrolysis in 40–45 days, independent of the patient’s enzymatic activity, retaining 50% of the initial tensile strength at 5 days and losing it completely at 14 days. This short support window makes it suitable for superficial tissues, mucous membranes and temporary approximation of soft tissues where suture removal is not required.
The ½ circle needle with cylindrical body and conical Taperpoint point (HR 36) combines the strength of a round body with a point that separates fibres without aggressive cutting effect, minimising tissue trauma. The colourless grooved thread facilitates handling and sliding in the field. The product is supplied sterile by gamma radiation, is single-use and cannot be re-sterilised: check the integrity of the packaging and the expiry date before each procedure.
3. Technical Specifications
3.1. General characteristics (Factory ref. P2L22HR3601 · SKU AMP2L22HR3601)
| Parameter | Specification |
| Thread material | Polyglactin 910 (copolymer 90% glycolide / 10% L-lactide), low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 1 (metric 4) |
| Thread diameter | 0.40 – 0.499 mm (indicative, according to Pharmacopoeia) |
| Thread colour | Colourless |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Conical grooved (Taperpoint) |
| Needle size | HR 36 mm |
| Thread length | 75 cm (1 strand) |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal; excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units (minimum order 30 boxes) |
| Factory reference | P2L22HR3601 |
| SKU Cahnos | AMP2L22HR3601 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
3.3. Size equivalence
| USP size | Metric size | Approximate diameter |
| 1 | 4 | 0.40 – 0.499 mm (indicative, according to Pharmacopoeia) |
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is the most widespread category of fast-acting braided multifilament absorbable in the surgical market. This reference shares material (polyglactin 910 RAPID), absorption profile (≈42 days), tensile retention (≈50% at 5 days / 0% at 14 days), USP 1 gauge, ½ circle curvature and colourless thread with the VICRYL RAPIDE line from the leading company in the sector. Only references whose codes and attributes have been verified in official catalogues and authorised distributors are included:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | W9964 – USP 1, ½-circle needle 36 mm tapercut point, 90 cm | Comparable by category (not interchangeable 1:1) | Same material and rapid absorption profile (≈42 days), USP 1 gauge, colourless thread and ½ circle curvature with 36 mm needle; the differences are the point geometry (tapercut versus Taperpoint HR 36 of this reference), thread length (90 cm versus 75 cm) and the braid coating. Code confirmed in EMEA catalogue and authorised distributors. |
| Ethicon (J&J MedTech) | VICRYL RAPIDE (braided polyglactin 910, colourless) | VR944 – USP 3/0, ½ circle 36 mm needle conical point (CT-1), 90 cm | Comparable by category (not interchangeable 1:1) | It matches in material, rapid absorption, 36 mm conical point and colourless colour, but differs in gauge (USP 3/0 versus USP 1) and thread length (90 cm versus 75 cm). It does not reproduce the USP 1 / 75 cm combination of this reference. |
There is no equivalence table validated by the manufacturer for the exact configuration USP 1 + ½ circle needle conical Taperpoint HR 36 mm point + 75 cm colourless thread; consult the technical department before use in tenders. Homologous ranges in the rapid absorption segment include Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), comparable in material and absorption profile, although their specific codes for this exact combination must be confirmed with each manufacturer. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
5. Selection tips and variants of interest
To choose the most appropriate suture, assess the wound support time required by the tissue and the gauge according to the anatomical area. USP 1 gauge (metric 4) with 36 mm Taperpoint conical needle is a common choice for approximation of skin and mucous membranes, subcutaneous tissue, ligatures of small and medium-calibre vessels and ophthalmic surgery, with early strength loss (50% at 5 days; 0% at 14 days) that avoids suture removal in many indications.
Within the same PGLAR Polyglactin 910 RAPID Prime range with cylindrical conical-point needle, Cahnos offers complementary configurations: the standard quality of the same assembly (AM2L22HR3601), the 90 cm version (AMP2L23HR3601), the lower gauge USP 0 with HR 36 needle in 75 cm (AMP2L22HR3610), the HR 30 needle in USP 0 (AMP2L22HR3010) and the polyglycolic acid PGAR variant of the same format (AMP223HR3601). If the service prefers to thread, consult the needle-free presentations of the family. The colourless version offers maximum discretion in the field; if greater visibility is required, request the same configuration in dyed thread on demand. For special B2B conditions, volume orders or equivalences from other commercial houses, contact the technical-commercial team of Cahnos.