Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID in Prime quality of Polyglactin 910 (PGLAR) is the reference surgical closure solution when the procedure requires short-term wound support, fully predictable resorption and excellent tissue handling. This presentation incorporates two undyed threads of 90 cm mounted with a ½ circle needle of 36 mm, cylindrical body and conical point (Taperpoint), ensuring maximum discretion and an atraumatic passage through soft and well-perfused tissues. Especially indicated for subcutaneous tissue, mucosa, approximation of delicate tissues, ligation of small and medium-calibre vessels and ophthalmic surgery.
Presented in a box of 12 sterile units, it is a reliable and cost-effective option for operating theatres, day hospitals, ambulatory surgery, ophthalmology services and hospital supply contracts, with a minimum order of 30 boxes. A solution with traceability, consistent quality and excellent value for money for purchasing centres.
2. Technical explanation
Polyglactin 910 (PGLAR) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided multifilament structure with a grooved finish that provides flexibility, low shape memory, smooth passage through tissues and firm, secure knot tying.
In its RAPID variant (low molecular weight), absorption occurs by hydrolysis —a predictable process independent of the patient’s enzymatic activity— within a period of 40 to 45 days, retaining approximately 50 % of the initial tensile strength at 5 days and losing it completely at 14 days. This makes it ideal for superficial tissues and temporary approximation of soft tissues where material removal is not required.
The ½ circle needle with cylindrical body and conical point (profile HR36, Taperpoint) offers atraumatic penetration by separating the fibres without tearing them. The undyed grooved thread facilitates handling and firm knotting. Gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties. Single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. P2L23HR3620.2)
| Parameter | Specification |
|---|---|
| Material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Family / version | PGLAR – RAPID (rapid absorption), Prime quality (PREMISUT RAPID) |
| Gauge | USP 2/0 (metric 3) |
| Thread diameter | 0.30 – 0.339 mm (indicative, according to Pharmacopoeia) |
| Thread colour | Colourless |
| Thread length | 2 threads × 90 cm (2×90 cm) |
| Needle shape | Half circle (1/2, 160°) |
| Needle body | Cylindrical |
| Needle tip | Conical / Taperpoint |
| Needle size | HR 36 mm (Prime quality) |
| Absorption mechanism | Hydrolysis, 40–45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Factory reference | P2L23HR3620.2 |
| SKU Cahnos | AMP2L23HR3620.2 |
| Commercial format | Box of 12 units (minimum order 30 boxes) |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
|---|---|
| 5 days | 50 % of initial tensile strength |
| 14 days | 0% (total loss of tensile support) |
| Total absorption | 40–45 days, by hydrolysis (predictable and uniform rate) |
The cited retention profile corresponds to the rapid absorption formulation (RAPID line); it should not be confused with standard absorption polyglactin 910 (PGLA line, 56–72 days), also available in our catalogue.
4. Equivalences and Cross-References
Rapid absorption polyglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market. This reference shares material, USP 2/0 calibre, ½ circle curvature, 36 mm cylindrical conical-point needle, undyed 90 cm thread and rapid absorption profile with the homologous line of the sector’s main manufacturer. Only the reference whose code and complete attributes have been verified in the manufacturer’s official catalogue and authorised distributors is included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | V9450H (EMEA) | Comparable by category (not interchangeable 1:1) | They match: rapid absorption polyglactin 910 material (≈42 days), USP 2/0 calibre, ½ circle 36 mm needle with conical point (CT-1 PLUS / Taperpoint) and undyed 90 cm thread. They differ: this reference adds a second thread (2×90 cm vs 1×90 cm), the needle nomenclature (CT-1 PLUS vs HR36 Prime), the braid coating (calcium stearate) and the packaging format (36 units in Ethicon). Code confirmed in Ethicon’s EMEA catalogue and authorised distributors. |
Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI), braided multifilaments with short-term tensile strength retention; they are not included in the table because no verified code is available for the exact combination USP 2/0 / 36 mm needle / Taperpoint conical point / double 90 cm thread (pending confirmation with the manufacturer before use). Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
The USP 2/0 (metric 3) calibre offers an optimal balance between strength and fineness, indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa and soft tissue in general, as well as for ligation of small and medium-calibre vessels. The cylindrical conical-point needle (Taperpoint) is especially recommended for soft and well-perfused tissues, where an atraumatic passage without cutting effect is sought, including ophthalmic surgery.
Within the same PGLAR RAPID range with HR36 needle, Cahnos offers complementary configurations:
| Reference | Variant |
|---|---|
| AMP2L23HR3620 | PGLAR RAPID Prime USP 2/0, HR36 needle, undyed, 1 thread of 90 cm |
| AM2L23HR3620 | PGLAR RAPID USP 2/0 (standard quality), HR36 needle, colourless, 90 cm |
| AM2L22HR3620 | PGLAR RAPID USP 2/0, HR36 needle, undyed, 75 cm |
| AM2L23HR3610 | PGLAR RAPID USP 0, HR36 needle, undyed, 90 cm |
| AM2L23HR3601 | PGLAR RAPID USP 1, HR36 needle, undyed, 90 cm |
| AM2L23HRT3620 | PGLAR RAPID USP 2/0, trocar point needle Tapercut HRT36, colourless, 90 cm (firmer tissues) |
All references are supplied in a box of 12 units, with a minimum order of 30 boxes to guarantee the continuous supply of your healthcare centre. The colourless version offers maximum discretion in the field; if you require greater visibility, consider the same configuration in violet on request. As this is a sterile single-use product, check the integrity of the packaging and the expiry date before each procedure and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews