Description
1. Commercial Introduction
The Absorbable Multifilament Suture PREMISUT RAPID of Polyglactin 910 (PGLAR) in Prime quality is the high-performance reference from Cahnos for closures requiring short wound support, predictable resorption and excellent handling. Its ½ circle needle with cylindrical body and 17 mm taper point Taperpoint (HR17) penetrates delicate tissues with minimal trauma, making it especially suitable for ophthalmic surgery, approximation of soft tissues, mucous membranes and ligation of small-calibre vessels.
Presented in a box of 12 units with advantageous terms for supply contracts, it is a sterile, reliable and cost-effective solution for operating theatres, day hospitals, ambulatory surgery and B2B purchasing centres.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, spun into a braided and grooved multifilament structure that provides great flexibility, excellent glide and a firm, secure knot. In its RAPID variant (low molecular weight), the thread is formulated to lose tensile strength in an accelerated and programmed manner: it retains 50 % of the initial strength at 5 days and 0 % at 14 days, with complete absorption by hydrolysis between 40 and 45 days.
This rapid absorption profile makes it ideal for tissues that heal quickly and only need transient support (7–10 days), without the need to remove the material. The ½ circle needle (160°) with atraumatic taper point minimises trauma during thread passage, and the colourless colour facilitates maximum discretion on the surgical field. Sterile single-use product, sterilised by gamma radiation, not re-sterilisable.
3. Technical Specifications
| Material | Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide), RAPID variant |
| Structure | Braided multifilament, grooved finish |
| Gauge | USP 5/0 (metric 1; approximate diameter 0.10–0.149 mm according to Pharmacopoeia) |
| Colour | Colourless (undyed) |
| Thread length | 75 cm |
| Needle shape | ½ circle, cylindrical body |
| Needle tip | Taperpoint conical (atraumatic) |
| Needle size | 17 mm (HR17) |
| Absorption | By hydrolysis, complete at 40–45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal |
| Indications | Approximation of delicate tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units · Minimum order 30 boxes |
| Manufacturer reference | P2L22HR1750 · SKU AMP2L22HR1750 |
Absorption and strength retention profile
| Parameter | Value |
| Absorption type | Hydrolysis |
| Absorption time | 40–45 days |
| Tensile strength at 5 days | 50% of initial strength |
| Tensile strength at 14 days | 0% (total loss of tensile support) |
| Wound support | 7–10 days |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. At category level, rapid-absorption polyglactin 910 (low molecular weight) is the most widely used absorbable multifilament in the surgical market. Only one code is included whose attributes have been consistently verified in Ethicon / J&J MedTech datasheets and catalogues of authorised distributors:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon / Johnson & Johnson MedTech | VICRYL RAPIDE™ (polyglactin 910, braided, colourless) · RB-1 ½ circle taper point needle 17 mm · 75 cm | W9969 | Comparable by category (not interchangeable 1:1) | Same material (Polyglactin 910 RAPID), same USP 5/0 gauge, 75 cm colourless thread, ½ circle taper point needle of 17 mm: almost total match of specifications. Only formal difference: the needle designation (RB-1 Ethicon vs HR17 Cahnos), with equivalent geometry and size. Code confirmed in Ethicon EMEA catalogue and multiple authorised distributors. |
Homologous ranges in the rapid absorption segment include Safil Quick and NOVOSYN Quick (B. Braun), braided multifilaments of poly(glycolide-co-L-lactide) with short tensile strength retention, as well as DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI); no specific codes are included because no verified references are available for this exact combination of gauge, needle and point. Standard VICRYL (absorption 56–72 days) is not comparable to this RAPID version.
5. Selection tips and variants of interest
Before substituting this reference for another, verify three fields against the service protocol: thread gauge (USP 5/0), needle curvature and length (½ circle, 17 mm) and point type (taper point Taperpoint). Gauge 5/0 is a common choice in microsurgery and very delicate tissues (conjunctival suture, mucous membranes, approximation of fine tissue), where the taper point minimises trauma.
Within the same cylindrical PGLAR RAPID range, Cahnos offers complementary configurations: the standard (non-Prime) version in this same configuration (AM2L22HR1750), USP 4/0 gauge with the same needle and thread (AM2L22HR1740), 3/0 in Prime quality (AMP2L22HR1730) and standard (AM2L22HR1730), as well as larger needle sizes HR22, HR26 and HR36 for higher gauges. If the tissue is firm, the triangular reverse cutting family (HS17, HS22, HS40) is the alternative; for fibrous tissues, the Tapercut trocar point (HRT36). For recurrent operating theatre purchases, remember that the minimum order is 30 boxes of 12 units, ideal for supply contracts and centralised replenishment.