Description
1. Commercial Introduction
The absorbable multifilament suture PGLAR of Polyglactin 910 RAPID (PREMISUT RAPID range) is a high-performance surgical reference designed for the professional B2B channel: hospitals, ophthalmology clinics, purchasing centres and surgical services that need a braided, flexible thread with early, predictable and documented loss of strength. It is supplied mounted with a ½ circle needle with cylindrical body and taperpoint conical tip of 48 mm (HR 48), USP 0 gauge and 90 cm colourless grooved thread, in a box of 12 units with a minimum order of 30 boxes for hospital replenishment.
Its combination of manoeuvrability, secure knot tying and controlled reabsorption makes it a common choice in skin and mucosa approximation, ligatures, episiotomies, paediatric surgery and ophthalmic surgery, with an excellent balance between cost and clinical performance.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in this reference in its low molecular weight variant (RAPID), which accelerates the loss of strength and mass compared with conventional polyglactin 910. Its braided multifilament structure with grooved finish and coating provides very smooth handling, controlled sliding and firm knot tying.
Absorption occurs by hydrolysis, i.e. by chemical degradation of the polymer in contact with tissue fluids, without depending on enzymes, over a predictable period of 40 to 45 days and with minimal tissue reaction. The tensile strength retention profile is 50 % at 5 days and 0 % at 14 days, so it is especially indicated for tissues that only require short-term support. The ½ circle needle with taperpoint conical tip penetrates soft tissues by separating the fibres without tearing them. The product is supplied sterile by gamma radiation, is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
| Thread material | Polyglactin 910 (PGLAR), copolymer 90% glycolide / 10% L-lactide, low molecular weight variant (RAPID) |
| Thread structure | Braided coated multifilament, fluted finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint |
| Needle size | HR 48 mm |
| Thread length | 90 cm |
| Absorption mechanism | Hydrolysis |
| Absorption period | 40 – 45 days |
| Tensile strength retention | 50 % at 5 days / 0 % at 14 days |
| Sterilisation | Gamma radiation |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 sterile units |
| Minimum order | 30 boxes |
| Factory reference | 2L23HR4810 |
| SKU Cahnos | AM2L23HR4810 |
3.2. Tensile strength retention profile
| Post-implantation time | Retained tensile strength |
| 5 days | 50 % |
| 14 days | 0 % |
Complete absorption by hydrolysis between 40 and 45 days, with minimal tissue reaction, excellent initial tensile strength and optimal knot tying.
4. Equivalences and Cross-References
Rapid-absorption polyglactin 910 (low molecular weight) is one of the most widely used synthetic absorbable materials with rapid absorption on the market. The analysed reference is comparable at category level with braided polyglactin 910 RAPID sutures from other manufacturers, both in composition and in absorption profile (≈42 days) and tension retention (≈50 % at 5 days):
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE, CTX 48 mm needle, ½ circle taperpoint, USP 0, 90 cm, colourless | VR1695 | Comparable by category (not interchangeable 1:1) | Same composition (rapid-absorption polyglactin 910), USP 0 gauge, 90 cm colourless thread and ½ circle conical tip needle of 48 mm; the coating and needle body may differ slightly. Confirmed in GUDID (Ethicon LLC) as VICRYL RAPIDE Undyed Braided Polyglactin 910. |
Other homologous lines of rapid-absorption polyglactin 910 that can serve as a functional reference in the same indication, although without a 1:1 equivalence published by the manufacturer, are the families of rapid absorbable braided sutures from B. Braun (Safil Quick / Novosyn Quick type range) and the rapid absorbable braided lines from Medtronic, whose specific codes for USP 0 gauge with HR 48 needle must be confirmed with each manufacturer. There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering.
5. Selection tips and variants of interest
Before ordering, check three parameters: the USP gauge (for delicate tissues, fine gauges 4/0, 3/0 and 2/0 are recommended; USP 0 is reserved for tissues requiring intermediate-high initial strength), the needle geometry (the ½ circle with taperpoint conical tip is the most suitable for soft tissues and confined spaces) and the thread length (90 cm, ideal for general surgery and material replenishment). Variants of interest within the same family:
- AMP2L23HR4810: same reference in PRIME quality (factory ref. P2L23HR4810), same geometry and gauge, superior range.
- AMP2L23HR4810.2: PRIME in double format of 2 × 90 cm (higher yield per package).
- AM2L23HR4801 / AM2L23HR4802: PGLAR RAPID HR 48 in USP 1 and USP 2 gauges, 90 cm colourless thread (same needle, different gauge).
- 1L23HR4802: conventional polyglactin 910 (absorption 56-72 days and longer strength retention) when healing requires support for more than 2 weeks.
- AM223HR4801: rapid suture of polyglycolic acid (PGAR) HR 48 USP 1 (material alternative within rapid absorption).
- PDO family (polydioxanone): for prolonged strength retention (180-210 days) in tissues under sustained tension.
All references are supplied in boxes of 12 units. As this is a sterile single-use product, check the integrity of the packaging before each procedure. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews