Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID of Polyglactin 910 (PGLAR) is the technical choice when the procedure requires short-term wound support, predictable reabsorption and excellent handling. Its ½ circular 22 mm needle with reverse cutting triangular point (HS22) penetrates firm and non-lax tissues with minimal tissue trauma, ideal for ophthalmic surgery, approximation of superficial tissues and ligatures.
Presented in a box of 12 units, it is a sterile and reliable solution for operating theatres, day hospitals, ambulatory surgery and hospital supply contracts.
2. Technical explanation
Polyglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided and grooved multifilament structure that provides flexibility, smooth passage and a secure knot. In the RAPID variant (low molecular weight), absorption occurs by hydrolysis in 40–45 days, retaining 50% of its tensile strength at 5 days and losing it completely at 14 days; this makes it suitable for tissues that only require transient support (7–10 days) without the need to remove the material.
The ½ circle needle (160°) with reverse cutting triangular body and point (type HS22, 22 mm) penetrates firm tissues such as skin, mucosa or conjunctiva with a clean exit path, reducing tearing. The colourless thread facilitates clinical concealment, and gamma radiation sterilisation guarantees final sterility with minimal alteration of mechanical properties.
3. Technical Specifications
| Characteristic | Specification |
| Material | Polyglactin 910 (copolymer 90 % glycolide / 10 % L-lactide) |
| Structure | Braided multifilament, grooved |
| Family / version | PGLAR – RAPID (rapid absorption) |
| Gauge | USP 3/0 |
| Colour | Colourless (undyed) |
| Thread length | 45 cm |
| Needle | ½ circle, triangular body and point, 22 mm (HS22) |
| Needle tip | Triangular – reverse cutting (reverse cutting) |
| Absorption | By hydrolysis, 40–45 days |
| Tensile strength | 50% at 5 days; 0% at 14 days |
| Wound support | 7–10 days |
| Sterilisation | Gamma radiation |
| Indications | Approximation of superficial tissues, ligatures and ophthalmic surgery |
| Manufacturer reference | P2L21HS2230 |
| Commercial format | Box of 12 units |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. At category level, this suture is comparable by family with the rapid absorption polyglactin 910 lines on the market. The following code has been verified in the official catalogue and authorised distributors, but it does not reproduce the exact combination of reverse cutting / 22 mm needle / 45 cm thread of this reference:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon / Johnson & Johnson | VICRYL RAPIDE (polyglactin 910, braided, colourless) | W9927 | Comparable by category (not interchangeable 1:1) | Same material and rapid absorption (≈42 days), same USP 3/0 gauge, 22 mm needle in ½ circle and 45 cm of thread; however, it mounts a conventional cutting point (PC-22/PS-22) and not a reverse cutting one. Code confirmed in the Ethicon EMEA catalogue and authorised distributors. |
Other homologous lines in the rapid absorption segment are Safil Quick and NOVOSYN QUICK (B. Braun), braided multifilaments of poly(glycolide-co-L-lactide) with short retention of tensile strength; they are not included in the table because no verified code is available for this exact combination of gauge, needle and point (pending confirmation with the manufacturer before use).
5. Selection tips and variants of interest
For this same PGLAR RAPID family, Cahnos offers variants with other configurations: ⅜ circle reverse cutting triangular needle in gauges 2/0 (DS24 mm, ref. AMP2L22DS2420) and 4/0 (DS16 mm, ref. AMP2L22DS1640); ½ circle cylindrical needle with conical point in gauge 5/0 (HR17 mm, ref. AMP2L22HR1750); or Tapercut trocar point in gauge 0 (HRT36 mm, ref. AMP2L22HRT3610).
If the service prefers reverse cutting with a smaller radius for very delicate tissues, the HS family of 3/8 circle is the natural alternative; if the tissue is lax, the cylindrical conical point reduces trauma even further. Remember to verify gauge, needle geometry and thread length against your protocol before substituting one reference for another.





Reviews