Description
1. Commercial Introduction
The absorbable multifilament suture PREMISUT RAPID Poliglactin 910 (PGLAR) in Prime quality is the technical solution when the procedure requires short-term wound support with predictable and controlled resorption. This presentation incorporates a ½ circular needle of 17 mm with a triangular reverse cutting point, which facilitates penetration into fine and firm tissues with minimal trauma, and a colourless 45 cm thread in USP 3/0 gauge. It is a reliable and sterile option for general surgery operating theatres, emergency departments, ophthalmology clinics and B2B purchasing centres, available in a box of 12 units with advantageous conditions for supply contracts.
2. Technical Explanation
Poliglactin 910 is a synthetic copolymer composed of 90% glycolide and 10% L-lactide, spun into a braided multifilament structure coated with a grooved finish that favours thread sliding, smooth handling and a firm, secure knot. In its RAPID variant (low molecular weight poliglactin 910), absorption occurs by hydrolysis in 40-45 days, retaining approximately 50% of its tensile strength at 5 days and losing it completely at 14 days, making it suitable for superficial tissues, mucous membranes and temporary approximation of soft tissues. The reverse cutting needle creates a clean entry hole by directing the cut away from the wound, preserving the skin edge and preventing the cut from enlarging in the puncture bed. The product is sterile, single-use and non-resterilisable.
3. Technical Specifications
3.1. General characteristics (Ref. AMP2L21HS1730)
| Parameter | Specification |
| Material | Polyglactin 910 (PGLAR), copolymer 90 % glycolide / 10 % L-lactide, RAPID variant |
| Thread structure | Braided coated multifilament, fluted finish |
| Quality | Prime (PREMISUT RAPID range) |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Colourless |
| Thread length | 45 cm |
| Needle shape | ½ circle |
| Needle tip | Triangular, reverse cutting |
| Needle size | HS 17 mm |
| Sterilisation | Gamma radiation; single-use, not re-sterilisable |
| Tissue reaction | Minimal, with excellent tensile strength and knot tying |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Commercial format | Box of 12 units (minimum order 30 boxes) |
| Reference | AMP2L21HS1730 |
3.2. Absorption profile and tensile strength retention
| Parameter | Value |
| Absorption type | Hydrolysis |
| Absorption time | 40 – 45 days |
| Tensile strength at 5 days | 50% of initial strength |
| Tensile strength at 14 days | 0% (total loss of tensile support) |
| Absorption rate | Predictable and uniform |
4. Equivalences and Cross-References
Rapid-absorption poliglactin 910 (low molecular weight) is the most widespread multifilament absorbable category in the surgical market. This reference shares material, USP 3/0 gauge, colourless 45 cm thread and rapid absorption profile with the homologous lines of the main manufacturers in the sector. Only codes whose attributes have been verified in official catalogues and authorised distributors are included:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | MPVR4970H – USP 3/0, PS-2 needle 19 mm, ⅜ circle, reverse cutting, 45 cm | Comparable by category (not interchangeable 1:1) | Same material, USP 3/0 gauge, colourless colour and 45 cm length; the needle curvature differs (⅜ circle vs ½ circle) and the size (19 mm vs HS 17 mm). Code confirmed in authorised distributors. |
| Ethicon (Johnson & Johnson MedTech) | VICRYL RAPIDE (polyglactin 910, braided, colourless) | V6830H – USP 3/0, PS-1 needle, 45 cm, colourless | Comparable by category (not interchangeable 1:1) | Same material, gauge and length; the needle geometry differs from the ½ circle HS 17 mm profile. Verify the official datasheet before any substitution. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. As homologous ranges in the rapid absorption segment, Safil Quick / Novosyn Quick (B. Braun), DemeCRYL Fast (DemeTECH) and Surgicryl Fast Absorb (SMI) appear, comparable by category by material and absorption profile, although for the exact combination USP 3/0 / HS 17 mm needle / 45 cm, their specific codes must be confirmed with the manufacturer. Standard VICRYL (absorption 56-72 days) is not comparable to this RAPID version.
5. Selection tips and variants of interest
The USP 3/0 gauge (metric 2) is a common choice in ophthalmic surgery and in fine tissues where an optimal balance between strength and fineness is required: conjunctival suture, mucosal approximation, subcutaneous tissue and ligation of small-calibre vessels. The ½ circle reverse cutting needle of 17 mm is especially recommended when a firm and precise passage through skin or mucous membranes is required without tearing the edge, typical in microsurgery and ophthalmology. Within the same PGLAR RAPID range, Cahnos offers complementary configurations: the 75 cm variant with the same needle and gauge (AMP2L22HS1730), the USP 4/0 gauge with 45 cm thread (AMP2L21HS1740), the HS 40 mm needle in USP 0 with 90 cm thread (AM2L23HS4010), the version with cylindrical needle with conical point HR 17 (AMP2L22HR1730) for looser tissues, and the rapid polyglycolic acid line PGAR (AMP221HS1730) as a material alternative within the same absorption profile. Sterile single-use product: check the integrity of the packaging and the expiry date before each procedure. For special B2B conditions or volume orders (minimum 30 boxes), contact the technical-commercial team of Cahnos.





Reviews