We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) PREMISUT Prime | Needle ⅜ Circle Triangular Point Reverse Cutting DS 24 mm | USP Size 2/0 (Metric 3) | Violet Braided Thread 75 cm | Ref. P1L12DS2420 – Box of 12 units

Original price was: 39,90 €.Current price is: 31,30 €.

Absorbable suture PREMISUT Prime of Polyglactin 910 (PGLA): violet braided fluted multifilament thread, 75 cm and USP 2/0 gauge (metric 3). Includes a ⅜ circle needle with reverse cutting triangular point of 24 mm (DS 24 mm), ideal for firm tissues such as sclera, skin, fascia and ligatures. Predictable absorption by hydrolysis in 56-72 days with strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use and minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. P1L12DS2420, presentation in box of 12 units with special B2B conditions.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L12DS2420

Description

1. Commercial presentation

The multifilament absorbable suture of Polyglactin 910 (PGLA) reference P1L12DS2420, from the PREMISUT Prime quality range, is the reference solution for B2B supply to operating theatres, ophthalmology clinics, purchasing centres and distributors. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security for the approximation of soft tissues, ligatures and ophthalmic surgery.

Its ⅜ circle needle with reverse cutting triangular point of 24 mm (DS 24 Prime) ensures firm and controlled penetration even in dense and non-compliant tissues, while the 75 cm violet braided fluted thread offers smooth glide during suturing and optimal visibility on the surgical field. It is a synthetic absorbable medical device, sterile by ethylene oxide, single-use and non-resterilisable, with an excellent value-for-money ratio for the continuous supply of your centre.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 2/0.

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, independent of the patient’s enzymatic activity. This profile maintains the necessary tensile strength during the first weeks of healing (75% at 2 weeks, 50% at 3 weeks and 30% at 4 weeks), while the tissue recovers its own resistance.

The ⅜ circle needle with reverse cutting triangular point penetrates firm and fibrous tissues with controlled trauma, avoiding tears, which is why it is especially indicated in sclera and ophthalmic tissues, as well as in tissue approximation and ligatures. The violet colour improves thread visibility on the surgical field. The product is supplied sterile by ethylene oxide and must not be resterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L12DS2420

Parameter Specification
Brand / Range PREMISUT (Prime quality, premium range)
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 2/0 (metric 3)
Thread colour Violet (also available undyed in the range)
Needle shape ⅜ circle
Tip type Triangular with reverse cutting (inverted triangular)
Needle size DS 24 mm (Prime)
Thread length 75 cm
Absorption mechanism By hydrolysis, between 56 and 72 days
Sterilisation Ethylene oxide (single-use, not re-sterilisable)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L12DS2420

3.2. Tensile strength retention profile after implantation

Time point Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days (hydrolysis)

Complete absorption by hydrolysis between 56 and 72 days with minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

3.3. Size equivalence

USP size Metric size Approximate diameter
2/0 3 0.30 – 0.349 mm (indicative according to Pharmacopoeia)

4. Equivalences and Cross-References

Polyglactin 910 is the most widely used medium-term absorbable multifilament in the surgical market. This PREMISUT Prime suture is equivalent in composition and behaviour to the main commercial ranges of braided polyglactin 910:

Manufacturer / commercial house Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910, violet colour)
Assut Assucryl 910 (polyglactin 910)
Laboratorio Aragó (Premisut range) Braided multifilament polyglactin 910 with ⅜ circle needles (DS series)

Within the Cahnos catalogue, its direct equivalent in the standard range with the same configuration (triangular needle DS 24 mm, USP 2/0, violet and 75 cm) is reference 1L12DS2420. The Prime variant in colourless is P1L22DS2420, and in the polyglycolic acid (PGA) family with longer absorption (60-90 days) you will find AMP112DS2420. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.

5. Selection tips and variants of interest

To choose the most suitable suture, assess the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2/0 gauge (metric 3) is indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, muscle and ligatures, and is widely used in ophthalmic surgery. The reverse cutting triangular point needle (DS 24) is especially recommended for firm and non-compliant tissues, where the needle passage must be clean and without tears.

Reference Variant
P1L12DS2420 PGLA Prime USP 2/0, ⅜ triangular needle DS 24 mm, violet, 75 cm (current product)
P1L22DS2420 PGLA Prime USP 2/0, same needle DS 24 mm, colourless, 75 cm (maximum discretion in the field)
1L12DS2420 PGLA standard USP 2/0, same configuration DS 24 mm, violet, 75 cm (standard range)
P1L12DS2430 PGLA Prime USP 3/0, same needle DS 24 mm, violet, 75 cm (finer gauge)
P1L12DS2410 PGLA Prime USP 0, same needle DS 24 mm, violet, 75 cm (larger gauge)
P1L12DS2620 PGLA Prime USP 2/0, triangular needle DS 26 mm, violet, 75 cm (longer needle)
AMP112DS2420 PGA Prime USP 2/0, triangular needle DS 24 mm, violet, 75 cm (absorption 60-90 days)

In the Cahnos catalogue you will find other thread lengths (45, 70 and 75 cm), gauges from 4/0 to 0, double needle versions and other needle geometries (HS 22 mm, DS 26 and 30 mm, precision XDS and cylindrical types), as well as the PGLAR fast absorption range. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee the continuous supply of your healthcare centre. For special B2B conditions, volume orders or enquiries about additional gauges, lengths and colours on request, contact our Cahnos technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 2/0 (metric 3)

Needle size

DS 24 mm (Prime)

Tip type

Triangular with reverse cutting (inverted triangular)

Tensile strength

75 % (2 weeks), 50 % (3 weeks), 30 % (4 weeks)

Sterilisation

Ethylene oxide (single-use, not re-sterilisable)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Quality

Prime (range PREMISUT)

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

DS 24

Usp

2/0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) PREMISUT Prime | Needle ⅜ Circle Triangular Point Reverse Cutting DS 24 mm | USP Size 2/0 (Metric 3) | Violet Braided Thread 75 cm | Ref. P1L12DS2420 – Box of 12 units”

Your email address will not be published. Required fields are marked *