Description
1. Commercial Introduction
The absorbable multifilament suture PGLA (Polyglactin 910) from the Prime range is the reference choice in the operating theatre for professionals, hospitals, private clinics and purchasing centres looking for a high-performance synthetic thread with an excellent quality-price ratio. This reference mounts a ½ circle needle with cylindrical body and Taperpoint conical point of 40 mm (HR 40), USP 0 gauge (metric 3.5) and a 70 cm violet grooved thread, under the code P1L18HR4010.
Each unit is supplied sterile and ready to use, with the guarantee of professional distribution from Cahnos. It is especially indicated for the approximation of soft tissues, ligatures and ophthalmic surgery, where precision, manageability and totally predictable absorption are required during the first weeks of healing.
2. Technical Explanation
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its braided multifilament structure with a grooved finish gives it great flexibility, low memory and a low coefficient of friction, which favours the sliding of the thread through tissue, smooth handling and firm, secure knot tying.
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, without depending on the patient’s enzymatic activity. This profile makes it suitable for tissues requiring wound support for 2 to 4 weeks, maintaining the necessary tensile strength while the tissue recovers its own resistance.
The ½ circle needle with cylindrical body and conical point (Taperpoint) penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is especially recommended in ophthalmic surgery. The violet colour ensures optimal visibility of the thread in the surgical field. Sterile single-use product, with no possibility of re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference P1L18HR4010
| Characteristic | Specification |
| Reference (SKU) | P1L18HR4010 |
| Quality | Prime (Premisut range) |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 0 (metric 3.5) |
| Thread colour | Violet (also available in colourless) |
| Thread length | 70 cm |
| Needle shape | 1/2 circle |
| Needle body | Cylindrical |
| Needle tip | Taperpoint conical |
| Needle size | 40 mm (HR 40 Prime) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention profile
| Period | Remaining tensile strength |
| 2 weeks | 75% of initial tensile strength |
| 3 weeks | 50% of initial tensile strength |
| 4 weeks | 30 % of initial tensile strength |
| Total absorption | 56-72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying, indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture belongs to the family of synthetic braided absorbable sutures with medium absorption, clinically equivalent in composition, absorption profile and mechanical behaviour to the reference lines on the international market:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl / Vicryl Plus (braided polyglactin 910, violet) |
| B. Braun | Safil (braided polyglactin 910, violet) |
| Medtronic / Covidien | Polysorb (absorbable braided range) |
| SMI | Surgicryl (polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with cylindrical ½ circle needles (TC/HR series) |
Within the Cahnos catalogue, this reference is directly related to the following variants of the same PGLA Prime family with HR 40 mm needle: P1L13HR4010 (same configuration with 90 cm thread), 1L18HR4010 (standard quality, same 70 cm configuration), P1L18HR4030 (USP 3/0 gauge), P1L18HR4001 (USP 1 gauge) and P1L18HR4002 (USP 2 gauge). As an alternative in polyglycolic acid with 60 to 90 day absorption, reference AMP118HR4010 is available (PGA Prime, HR 40 mm needle, USP 0, violet, 70 cm). The equivalences indicated are for guidance; for a formal substitution, please consult our technical-commercial department.
5. Selection tips and variants of interest
USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, soft tissue approximation and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during healing of 2 to 4 weeks.
| Reference | Variant |
| P1L18HR4010 | PGLA Prime USP 0, HR 40 mm Taperpoint needle, violet, 70 cm (current product) |
| P1L13HR4010 | PGLA Prime USP 0, HR 40 mm needle, violet, 90 cm (longer thread length) |
| 1L18HR4010 | PGLA standard quality USP 0, HR 40 mm needle, violet, 70 cm |
| P1L18HR4030 | PGLA Prime USP 3/0, same HR 40 mm needle, violet, 70 cm (smaller gauge) |
| P1L18HR4001 | PGLA Prime USP 1, same HR 40 mm needle, violet, 70 cm (larger gauge) |
| P1L18HR4002 | PGLA Prime USP 2, same HR 40 mm needle, violet, 70 cm (larger gauge) |
| P1L18HS4010 | PGLA Prime USP 0, HS 40 mm triangular needle, violet, 70 cm (firm tissues) |
| AMP118HR4010 | PGA Prime USP 0, HR 40 mm needle, violet, 70 cm (60 to 90 day absorption) |
In ophthalmic surgery, prioritise ½ circle needles with Taperpoint conical point, which separate the fibres without cutting them and are ideal for soft and delicate tissues; for fibrous structures or the sclera, reverse cutting or trocar points are recommended. If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units with a minimum order of 30 boxes to ensure continuous supply to your healthcare centre. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight.





Reviews