Description
1. Product Presentation
The absorbable multifilament suture of Polyglactin 910 (PGLA) from Cahnos, within the Premisut range, is the reference synthetic resorbable solution for professionals who demand predictable behaviour, excellent tensile strength and great knot security. This presentation incorporates a ½ circle needle with a cylindrical body and conical point (taperpoint) of 17 mm (HR 17), USP 6/0 gauge (metric 0.7) and a 70 cm violet thread. It is the ideal choice for the approximation of soft tissues, ligatures and ophthalmic surgery, in a professional box format of 12 units, ideal for managing operating theatre stock, ophthalmic clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers.
2. Technical explanation of the material and procedure
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides smooth handling, low thread memory and firm, secure knot tying, even in fine gauges such as USP 6/0. Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. During the first weeks of healing it maintains the necessary tensile strength —75% at 2 weeks, 50% at 3 and 30% at 4—, the precise time for the tissue to recover its own resistance. The ½ circle needle with a cylindrical body and conical point (taperpoint geometry) combines an atraumatic point that separates fibres without a cutting effect with smooth passage through tissue: it is the usual configuration in ophthalmic surgery and in the approximation of delicate tissues. The violet colour of the thread guarantees optimal visibility on the surgical field, highly valued in deep planes and in microsurgery. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. Technical data sheet for reference 1L18HR1760
| Characteristic | Specification |
| Reference (SKU) | 1L18HR1760 |
| Brand / Quality | Premisut – Standard quality |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Suture type | Synthetic absorbable multifilament |
| Thread structure | Braided multifilament with grooved finish |
| Gauge | USP 6/0 (metric 0.7) |
| Thread colour | Violet (high visibility) |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Atraumatic conical (taperpoint) |
| Needle size | 17 mm (HR 17) |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56–72 days, by hydrolysis |
The absorbable Premisut suture of Polyglactin 910 offers controlled reabsorption and high technical performance, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
4. Equivalences and Cross-References
Polyglactin 910 is one of the most well-established synthetic multifilament absorbable suture raw materials on the market. This reference is clinically equivalent, in chemical composition, absorption profile (56–72 days) and tensile strength retention, to the main international lines:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
| Laboratory Aragó | Range 4xxxx (polyglactin 910) |
Within the Cahnos catalogue, its direct equivalent by needle profile and gauge is reference P1L18HR1760 (same HR 17 mm configuration in superior quality of the Premisut range), as well as the version in polyglycolic acid (PGA) AM118HR1760, with identical needle geometry and gauge. The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.
5. Selection tips and variants of interest
The USP 6/0 gauge (metric 0.7) is the finest in the HR 17 needle range, indicated for very delicate and low-tension tissues: mucosa, subcutaneous tissue, superficial planes and precision approximations, with special application in ophthalmic surgery, where aesthetic healing and minimal trauma are sought. The ½ circle 17 mm conical point needle is the most atraumatic option for these tissues.
- 1L18HR1730: same HR 17 mm needle and violet thread in USP 3/0 gauge (intermediate and versatile range).
- 1L28HR1750: same HR 17 mm needle in 5/0 gauge, colourless thread (minimal thread visibility).
- 1L18HRT1740: trocar point needle HRT 17 mm, USP 4/0 gauge (greater penetration in firm tissues).
- 1L12HR1360: short 13 mm needle, 6/0 gauge, violet, 75 cm thread (microsurgery).
- 1L18HR1730-2: double needle version for ophthalmic techniques.
All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews
There are no reviews yet.