Description
1. Product Presentation
The absorbable multifilament suture of Polyglactin 910 (PGLA) from the Prime Premisut range, reference P1L18HR1340, is the synthetic resorbable reference solution for the professional who demands predictable behaviour, excellent tensile strength and great security in knot tying. This presentation incorporates a 1/2 circle needle with cylindrical body and conical tip (taperpoint) of 13 mm (HR 13), USP gauge 4/0 (metric 1.5) and violet thread of 70 cm.
It is the ideal choice for approximation of soft tissues, ligatures and ophthalmic surgery, in professional format of box of 12 units, ideal for stock management of operating theatres, ophthalmology clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers.
2. Technical explanation of the material and procedure
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure. This configuration provides a regular surface that favours thread sliding through tissue, smooth handling, low memory and firm, secure knot tying, even in fine gauges such as USP 4/0.
Its absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, in a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. During the first weeks of healing it maintains the necessary tensile strength —75% at 2 weeks, 50% at 3 and 30% at 4—, the precise time for the tissue to recover its own resistance.
The 1/2 circle needle with cylindrical body and conical tip (taperpoint geometry) combines an atraumatic tip, which separates fibres without cutting effect, with a smooth and controlled passage through tissue. It is the usual configuration in ophthalmic surgery and in the approximation of delicate tissues. The violet colour guarantees optimal visibility on the surgical field. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
3. Technical Specifications
3.1. Technical data sheet for reference P1L18HR1340
| Characteristic | Specification |
|---|---|
| Reference (SKU) | P1L18HR1340 |
| Brand / Quality | Premisut – Prime |
| Suture type | Absorbable multifilament |
| Composition | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament |
| USP / metric gauge | 4/0 (metric 1.5) |
| Thread colour | Violet |
| Thread length | 70 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (taperpoint), atraumatic |
| Needle size | 13 mm (HR 13) |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
3.2. Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56–72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.
3.3. Indications for use
| Indication |
|---|
| Soft tissue approximation |
| Ligatures and internal closures |
| Ophthalmic surgery and precision techniques |
| Single-use, not re-sterilisable |
4. Equivalences and Cross-References
Polyglactin 910 is one of the most proven multifilament synthetic absorbable suture raw materials in surgical practice. This Prime reference is clinically equivalent, in chemical composition, absorption profile (56–72 days) and tensile strength retention, to the main international lines:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
| Laboratory Aragó | Range 4xxxx (polyglactin 910) |
Within the Cahnos catalogue, its closest equivalent by needle profile and gauge is reference P1L18HRP1340 (HRP needle of 13 mm with Ultra Plus trocar conical tip, same USP gauge 4/0), as well as the version with 17 mm needle P1L12HR1740 (USP 4/0, violet thread of 75 cm). The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
5. Selection tips and variants of interest
USP gauge 4/0 (metric 1.5) is indicated for fine tissues and moderate tension: mucosa, subcutaneous tissue, delicate planes and precision approximations, with special application in ophthalmic surgery, where aesthetic healing and minimal trauma are sought. The 1/2 circle conical tip needle of 13 mm is the most atraumatic option for these tissues.
- P1L18HR1330: same HR 13 mm needle, USP gauge 3/0, violet, 70 cm (intermediate and versatile range).
- P1L18HR1320: USP gauge 2/0, violet, 70 cm (larger diameter for higher tension).
- P1L18HR1310: USP gauge 0, violet, 70 cm (tissues with higher strength requirement).
- P1L18HRP1340: Ultra Plus trocar conical tip HRP 13 mm, USP 4/0 (reinforced penetration profile).
- P1L18HR1740VB: high visibility VisiBlack needle finish, HR 17 mm, USP 4/0.
- P1L28HR1740: same configuration with colourless thread, when minimal visibility of the strand is preferred.
- AMP118HR1340: equivalent in polyglycolic acid (PGA), absorption of 60–90 days.
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in a box of 12 units; the minimum order is 30 boxes to guarantee continuous supply for your healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each intervention, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.





Reviews