Description
The absorbable multifilament suture of Polyglactin 910 (PGLA) from Cahnos, within the Premisut range, is the reference synthetic resorbable solution for the professional who demands predictable behaviour, excellent tensile strength and great knot security. This presentation incorporates a ½ circle needle with cylindrical body and Taperpoint conical point of 17 mm (HR17), USP 2/0 gauge and 75 cm violet fluted thread. It is the ideal choice for soft tissue approximation, ligatures and ophthalmic surgery, in a professional format of box of 12 units, ideal for stock management in operating theatres, ophthalmology clinics and purchasing centres, with special B2B conditions for hospitals and volume buyers.
What this suture is and how it works
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted surface. This configuration provides great flexibility, smooth passage of the thread through tissue, low memory and firm, secure knot tying, even in working gauges such as USP 2/0, suitable for moderate tension tissues.
Its absorption occurs by hydrolysis, i.e., by progressive degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days and independent of the patient’s enzymatic activity. During the first weeks of healing it maintains the necessary tensile strength, the precise time for the tissue to recover its own resistance. The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) combines an atraumatic tip that separates fibres without cutting effect with smooth passage through tissue: it is the usual configuration in ophthalmic surgery and in delicate tissue approximation. The violet colour ensures optimal visibility on the surgical field, highly valued in deep planes and microsurgery. The product is sterilised by ethylene oxide (EO), is single-use and does not allow re-sterilisation.
Technical specifications
| Characteristic | Specification |
|---|---|
| Reference (SKU) | 1L12HR1720 |
| Brand / Quality | Premisut – standard |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament (grooved) |
| Gauge | USP 2/0 |
| Thread colour | Violet |
| Thread length | 75 cm |
| Needle shape | ½ circle |
| Needle body | Cylindrical |
| Needle tip | Conical (Taperpoint), atraumatic |
| Needle size | 17 mm (HR17) |
| Absorption mechanism | Hydrolysis (56–72 days) |
| Sterilisation | Ethylene oxide (EO), sterile, single-use |
| Tissue reaction | Minimal |
| Indications | Approximation of soft tissues, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
Tensile strength retention and absorption profile
| Period after implantation | Retained tensile strength |
|---|---|
| 2 weeks | 75 % of initial tensile strength |
| 3 weeks | 50 % of initial tensile strength |
| 4 weeks | 30% of initial tensile strength |
| Total absorption | 56–72 days, by hydrolysis |
Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot security. Price per box of 12 units.
Equivalences and cross-references
Polyglactin 910 is one of the most proven multifilament synthetic absorbable suture raw materials on the market. This reference is clinically equivalent, in chemical composition, absorption profile (56–72 days) and tensile strength retention, to the main international lines:
| Manufacturer / Company | Equivalent line |
|---|---|
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic (Covidien) | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (braided polyglactin 910) |
| Assut | Assucryl 910 (polyglactin 910) |
| DemeTECH | Vitacryl (coated braided polyglactin 910) |
Within the Cahnos catalogue, it shares the HR 17 needle configuration with references 1L12HR1750 (USP 5/0), 1L12HR1740 (USP 4/0) and 1L18HR1760 (USP 6/0), as well as with the polyglycolic acid (PGA) family with similar performance and absorption of 60–90 days, allowing comparison of suppliers and unification of stocks. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.
Selection tips and variants of interest
To choose the most suitable reference, consider the tissue support time required for each intervention: PGLA 910 offers an average absorption of 56 to 72 days, ideal for soft tissues that heal in 3–4 weeks. The USP 2/0 gauge provides a medium diameter that combines manageability and strength, suitable for approximation of tissues with moderate tension, ligatures and deep planes.
- 1L12HR1740: same HR 17 mm needle in standard quality, USP 4/0 gauge, 75 cm violet thread (finer gauge).
- 1L12HR1750: same HR 17 mm needle, USP 5/0 gauge, 75 cm violet thread (delicate tissues).
- 1L18HR1760: same HR 17 mm needle, USP 6/0 gauge, 70 cm violet thread with double needle.
- 1L28HR1740 / 1L28HR1750: same configuration with colourless thread, when minimal thread visibility is preferred.
- P1L12HR1720 (Prime range): same configuration in superior quality, for protocols requiring high performance.
If you need a longer retention profile (180–210 days) or a monofilament thread, the polydioxanone (PDO) family is the recommended alternative. All references are supplied in a box of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. As it is sterile single-use material, check the integrity of the packaging before each intervention, respect the expiry date and store in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other manufacturers, contact our technical-commercial team.