We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Polyglactin 910) Prime – Double Needle ½ Circle Cylindrical Body Taper Point HR17 mm – USP 3/0 – Grooved Violet Thread 2×70 cm – Box of 12 Units (Ref. P1L18HR1730-2)

Original price was: 39,90 €.Current price is: 34,10 €.

Absorbable multifilament Polyglactin 910 (PGLA) suture in Premisut Prime quality with atraumatic double needle, half circle, cylindrical body and taper point (Taperpoint) of 17 mm (HR17). USP gauge 3/0, grooved violet thread of 2×70 cm, with predictable hydrolysis absorption in 56-72 days and tension retention of 75 % at 2 weeks. Sterile by ethylene oxide and minimal tissue reaction; indicated for approximation of soft tissues, ligatures and ophthalmic surgery. Reference P1L18HR1730-2, presented in a box of 12 units with special B2B conditions for hospitals, clinics and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L18HR1730-2

Description

1. Product Presentation

The absorbable multifilament Polyglactin 910 (PGLA) suture in Premisut Prime quality, reference P1L18HR1730-2, is the benchmark synthetic absorbable solution for the professional who demands predictable performance, excellent tensile strength and high knot security. Its configuration of double needle, half circle with cylindrical body and taper point (Taperpoint) of 17 mm (HR17) allows continuous sutures with anchoring at both ends, optimising times and consumption in the operating theatre. It is the ideal choice for approximation of soft tissues, ligatures and ophthalmic surgery, in a professional box of 12 units.

2. Technical explanation of the material and procedure

Polyglactin 910 (PGLA) is a synthetic copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided (grooved) multifilament structure that provides great flexibility, smooth passage through tissue and excellent knotting behaviour. Its absorption occurs by hydrolysis, not by enzymatic action, over an interval of 56 to 72 days, allowing progressive, constant and predictable mass loss. It maintains tensile strength retention of 75 % at 2 weeks, 50 % at 3 weeks and 30 % at 4 weeks, a period sufficient for the healing of most soft tissues. The grooved violet thread ensures optimal visibility on the surgical field, highly valued in deep planes and microsurgery. The half-circle needle with cylindrical body and taper point (HR designation of 17 mm) passes through tissue with less resistance and without cutting effect on adjacent tissue, being ideal for ophthalmic procedures and lax tissues. The double needle (2xHR17 mm) format facilitates continuous sutures and bidirectional anchoring techniques, reducing thread manipulation during the procedure.

3. Technical Specifications

General characteristics:

Parameter Specification
Reference / SKU P1L18HR1730-2
Brand / Quality Premisut – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament (grooved)
Gauge USP 3/0
Thread length 70 cm per needle (2×70 cm, double needle)
Colour Violet
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (Taperpoint)
Needle size 17 mm (HR17) – double needle
Sterilisation Ethylene oxide
Presentation Box of 12 units
Minimum order 30 boxes

Absorption profile and tensile strength retention:

Parameter Value
Tensile strength retention at 2 weeks 75 %
Tensile strength retention at 3 weeks 50 %
Tensile strength retention at 4 weeks 30 %
Total absorption by hydrolysis 56 – 72 days
Tissue reaction Minimal, with excellent tensile strength and knot security
Indications Approximation of soft tissues, ligatures and ophthalmic surgery

4. Equivalences and Cross-References

Polyglactin 910 (PGLA) is one of the most widely used synthetic absorbable multifilament sutures on the market, which is why this Premisut Prime reference is clinically comparable with Ethicon’s Vicryl® line (Johnson & Johnson), with B. Braun’s Safil®, with Medtronic/Covidien’s Polysorb® and with SMI’s (Surgicryl) polyglactin 910 ranges, facilitating homologation processes in operating theatre protocols and hospital tenders. As for the needle, the half-circle format with cylindrical body and taper point of 17 mm corresponds to the classic pattern of small-format taper needles used in ophthalmic surgery and delicate tissues. Within the Cahnos catalogue, its direct equivalent in single needle with identical gauge, colour and length is reference P1L18HR1730 (USP 3/0, violet, 70 cm); the single-needle version with 75 cm thread is P1L12HR1730, and the colourless thread version is P1L28HR1730. In polyglycolic acid (PGA) material with similar performance, reference AMP118HR1730-2 offers the same double-needle format with 60-90 day absorption, allowing supplier comparison and stock unification.

5. Selection tips and variants of interest

To choose the most suitable reference, consider the tissue support time required for each procedure: PGLA 910 offers an average absorption of 56 to 72 days, ideal for soft tissues that heal in 3-4 weeks. The double-needle presentation P1L18HR1730-2 (3/0, 2×70 cm) is very practical for continuous sutures requiring anchoring at both ends; if you prefer a single needle of the same profile, you have P1L18HR1730 (3/0, 70 cm) and P1L12HR1730 (3/0, 75 cm). When the tissue is more fibrous and greater penetration capacity is required, the Tapercut trocar point variant P1L18HRT1730 is the recommended alternative; for a higher-grade taper point in double needle, consider P1L18HRP1730-2 (Ultra Plus). There are also alternative gauges with the same HR17 profile in violet thread: P1L12HR1720 (USP 2/0, 75 cm), P1L12HR1740 (USP 4/0) and P1L12HR1750 (USP 5/0). Consult our technical-commercial team to validate homologation with your purchasing centre and optimise your minimum order of 30 boxes with advantageous B2B rates.

Additional information

Reference

P1L18HR1730-2

Product line

Premisut – Prime

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Braided multifilament (grooved)

Gauge

USP 3/0

Thread length

2×70 cm (double needle)

Needle body

Cylindrical

Needle tip

Conical (Taperpoint)

Needle size

17 mm (HR17) – double needle

Sterilisation

Ethylene oxide

Tissue reaction

Minimal

Presentation

Box of 12 units

Minimum order

30 boxes

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Medida de aguja

2xHR 17 prime, HR 17

Usp

3/0

Color

Violet

Medida de hilo

2 × 70 cm, 70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)