We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) | ½ Circle Needle Cylindrical Body Conical Point HR 48 mm | USP Gauge 0 (Metric 3.5) | Violet Thread 90 cm | Ref. 1L13HR4810 | Box of 12 units

Original price was: 29,90 €.Current price is: 23,20 €.

Absorbable suture multifilament polyglactin 910 (PGLA) from the Premisut range, with a ½ circle needle with cylindrical body and conical point of 48 mm (HR 48), USP gauge 0 (metric 3.5) and 90 cm violet grooved thread. Predictable absorption by hydrolysis in 56-72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, single-use, with minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Ref. 1L13HR4810. Presentation in box of 12 units and minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L13HR4810

Description

1. Commercial Introduction

The absorbable multifilament polyglactin 910 (PGLA) suture, reference 1L13HR4810 from the Premisut range, is the reference surgical closure solution for professionals who demand a flexible, resistant thread with fully predictable absorption in the operating theatre. Its ½ circle needle with cylindrical body and conical point of 48 mm (HR 48) passes through soft tissues separating the fibres without cutting them, which minimises trauma and makes it especially suitable for tissue approximation, ligatures and ophthalmic surgery. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio for B2B supply to hospitals, ophthalmic clinics and purchasing centres, guaranteeing continuous supply to the healthcare facility.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a grooved finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, very smooth handling, comfortable sliding and firm, secure knot tying. Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains wound support during the first critical weeks of healing: it retains 75% of tensile strength at 2 weeks, 50% at 3 weeks and 30% at 4 weeks, while the tissue recovers its own resistance. The ½ circle needle, cylindrical body and conical point penetrates without cutting, minimising trauma to soft and friable tissues, while the violet colouration of the thread guarantees optimal visibility on the surgical field. The product is supplied sterile by ethylene oxide (EO), single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference 1L13HR4810

Characteristic Specification
Reference (SKU) 1L13HR4810
Range / Quality Premisut, Normal quality
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Colour Violet
Gauge USP 0 (metric 3.5)
Thread length 90 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (taper point)
Needle size 48 mm (HR 48)
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (EO); single-use, non-reesterilizable
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Total absorption 56-72 days, by hydrolysis

Excellent tensile strength and knot tying, with a fully predictable absorption rate and minimal tissue reaction.

3.3. Presentation and ordering conditions

Value Value
Presentation Box of 12 units
Minimum order 30 boxes
Format Sterile, single-use

4. Equivalences and Cross-References

Polyglactin 910 is one of the most widely used synthetic absorbable materials on the European market. This reference is clinically comparable, in terms of composition, absorption profile and tension retention, to the braided multifilament sutures of the main manufacturers:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (braided coated polyglactin 910, violet)
B. Braun Safil (braided polyglactin 910, violet)
Medtronic / Covidien Absorbable braided polyglactin 910 range
SMI Surgicryl (braided polyglactin 910, violet)

Within the Cahnos catalogue, the references closest to this configuration (HR 48 mm needle, USP gauge 0, violet) are the version with 75 cm thread (1L12HR4810), the alternative in polyglycolic acid (AM113HR4810) and the equivalent in Prime quality (P1L13HR4810). The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

USP gauge 0 (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ophthalmic surgery procedures, with an excellent balance between initial resistance and predictable absorption during healing of 2 to 4 weeks. The conical point (HR) separates the fibres without cutting them and is ideal for soft tissues; if the tissue is very friable, the most atraumatic option is the blunt point (HRN), while for firm and dense tissues the reverse cutting triangular point (HS) or the trocar point (HRT) is recommended.

Reference Variant
1L13HR4810 PGLA USP 0, conical point HR 48 mm, violet, 90 cm (current product)
1L13HR4801 PGLA USP 1, conical point HR 48 mm, violet, 90 cm
1L13HR4802 PGLA USP 2, conical point HR 48 mm, violet, 90 cm
1L13HR4010 PGLA USP 0, conical point HR 40 mm, violet, 90 cm
1L12HR4810 PGLA USP 0, conical point HR 48 mm, violet, 75 cm
1L13HRN4810 PGLA USP 0, blunt point HRN 48 mm, violet, 90 cm
1L13HS4810 PGLA USP 0, reverse cutting triangular point HS 48 mm, violet, 90 cm
1L13HRT4820 PGLA USP 2/0, trocar point HRT 48 mm, violet, 90 cm

For longer force retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to guarantee continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Structure

Multifilament braided fluted

Gauge

USP 0 (metric 3.5)

Needle body

Cylindrical

Tip type

Conical (taper point)

Absorption mechanism

Hydrolysis (56-72 days)

Sterilisation

Ethylene oxide (EO), single-use

Presentation

Box of 12 units

Minimum order

30 boxes

Quality range

Premisut, Normal quality

Intended use

Tissue approximation, ligatures and ophthalmic surgery

Medida de aguja

HR 48

Usp

0

Color

Violet

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament Suture PGLA (Polyglactin 910) | ½ Circle Needle Cylindrical Body Conical Point HR 48 mm | USP Gauge 0 (Metric 3.5) | Violet Thread 90 cm | Ref. 1L13HR4810 | Box of 12 units”

Your email address will not be published. Required fields are marked *