We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament Suture PGLA (Polyglactin 910) Prime PREMISUT – ½ Circle Needle Cylindrical Body Conical Point Taperpoint HR 17 mm – USP 4/0 Gauge – Colourless Thread 70 cm – Box of 12 units | Ref. P1L28HR1740

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable suture PREMISUT Prime of Polyglactin 910 (PGLA), colourless braided multifilament of 70 cm, with ½ circle needle of cylindrical body and Taperpoint conical point of 17 mm (HR17). USP 4/0 gauge (metric 1.5), predictable hydrolysis absorption in 56-72 days with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for soft tissue approximation, ligatures and ophthalmic surgery. Ref. P1L28HR1740, presented in box of 12 units with special B2B conditions for hospitals and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L28HR1740

Description

1. Product Presentation

PREMISUT presents the absorbable suture of Polyglactin 910 (PGLA) in Prime quality, a premium option designed to deliver superior performance in demanding medical procedures. This reference combines predictable absorption, excellent tensile strength retention and great knot security, making it the ideal choice for soft tissue approximation, ligatures and ophthalmic surgery. Its configuration with a ½ circle conical point needle of 17 mm and USP 4/0 gauge makes it a reliable and versatile solution for operating theatres, ophthalmic clinics and purchasing centres, with special B2B conditions for volume buyers.

2. Technical explanation of the material and procedure

Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted surface. This configuration provides smooth passage through tissue, excellent handling, low thread memory and firm, secure knotting even in fine gauges. Its absorption occurs by hydrolysis, independent of the patient’s enzymatic activity, over a predictable period of 56 to 72 days: the precise time for the tissue to regain its own strength during healing.

The ½ circle needle with cylindrical body and conical point (Taperpoint geometry) combines an atraumatic tip that separates fibres without cutting effect with smooth, controlled penetration, being the usual configuration in ophthalmic surgery and delicate tissues. The colourless thread ensures a discreet presence in the surgical field, highly valued in superficial and aesthetic planes. The product is sterilised by ethylene oxide (EO), is single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. Technical data sheet for reference P1L28HR1740

Characteristic Specification
Reference (SKU) P1L28HR1740
Brand / Quality PREMISUT – Prime
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament (grooved)
USP / metric gauge 4/0 (metric 1.5)
Thread colour Colourless
Thread length 70 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Conical (Taperpoint), atraumatic
Needle size 17 mm (HR 17)
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

3.2. Tensile strength retention and absorption profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56-72 days, by hydrolysis

Predictable and controlled absorption profile, with minimal tissue reaction, excellent tensile strength and optimal knot tying. Price per box of 12 units.

4. Equivalences and Cross-References

Polyglactin 910 is one of the most well-established synthetic multifilament absorbable suture raw materials on the market. This Prime reference is clinically equivalent, in chemical composition, absorption profile (56-72 days) and tensile strength retention, to the main international lines:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic (Covidien) Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910)
Assut Assucryl 910 (polyglactin 910)
DemeTECH Vitacryl (coated braided polyglactin 910)

Within the Cahnos catalogue, its closest equivalent by needle profile and gauge is reference P1L12HR1740 (same HR 17 mm needle and USP 4/0 gauge, violet thread of 75 cm), as well as the VisiBlack version P1L18HR1740VB (17 mm high-visibility needle, USP 4/0). The equivalences indicated are for guidance; for a formal substitution of references, please consult our technical-commercial department.

5. Selection tips and variants of interest

The USP 4/0 gauge (metric 1.5) is indicated for fine tissues and moderate tension: mucosa, subcutaneous tissue, delicate planes and precision approximations, with special application in ophthalmic surgery, where aesthetic healing and minimal trauma are sought. The ½ circle conical point needle of 17 mm is the most atraumatic option for these tissues.

  • P1L28HR1750: same HR 17 mm needle profile, USP 5/0 gauge, colourless, 70 cm (finer, for microsurgery and ophthalmology).
  • P1L28HR1730: USP 3/0 gauge, colourless, 70 cm (intermediate and versatile range).
  • P1L12HR1740: same configuration with violet thread of 75 cm, when greater visibility on the field is preferred.
  • P1L18HR1740VB: VisiBlack high-visibility needle finish, same gauge and needle profile.
  • P1L28HRT1740: trocar point (Tapercut) HRT 17 mm, for denser tissues.
  • AMP128HR1740: equivalent in polyglycolic acid (PGA), absorption of 60-90 days.

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. As this is sterile single-use material, check the integrity of the packaging before each procedure, respect the expiry date and store it in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial houses, contact our technical-commercial team.

Additional information

Brand

PREMISUT

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Multifilament braided fluted

USP size

4/0 (metric 1.5)

Needle body

Cylindrical

Needle tip

Conical Taperpoint, atraumatic

Needle size

17 mm (HR 17)

Absorption mechanism

Hydrolysis (56-72 days)

Sterilisation

Ethylene oxide (EO)

Presentation

Box of 12 units

Minimum order

30 boxes

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Medida de aguja

HR 17

Usp

4/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime