We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA Suture (Polyglactin 910) Premisut | Half-Circle Cylindrical Taperpoint Needle HR 36 mm | USP 2/0 Gauge (Metric 3) | Undyed Thread 90 cm | Ref. 1L23HR3620 – Box of 12 units

Original price was: 34,90 €.Current price is: 26,10 €.

Absorbable multifilament Polyglactin 910 (PGLA) suture from the Premisut range, reference 1L23HR3620, with a half-circle needle with cylindrical body and taper point of 36 mm, USP 2/0 gauge (metric 3) and an undyed braided thread of 90 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile product by ethylene oxide, single-use, with minimal tissue reaction, excellent tensile strength and high knot security. Indicated for soft tissue approximation, ligatures and ophthalmic surgery. Presentation in box of 12 units with a minimum order of 30 boxes. Ideal for the supply of operating theatres, ophthalmic clinics and purchasing centres.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L23HR3620

Description

The Absorbable Multifilament PGLA Suture (Polyglactin 910) reference 1L23HR3620, from the Premisut range by Cahnos, is the professional choice for surgery departments, ophthalmology and procedures requiring secure, manageable closure with controlled absorption. It combines a half-circle needle with a cylindrical body and taper point of 36 mm, an undyed braided thread of 90 cm in USP 2/0 gauge, and an economical presentation in a box of 12 units, designed for hospital and clinical supply with a minimum order of 30 boxes. A synthetic, sterile, single-use medical device with excellent value for money for the continuous supply of your centre.

Technical product explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, formed into a braided multifilament structure with a grooved finish. This configuration provides great flexibility, low shape memory, excellent initial tensile strength and smooth passage through tissue, with firm and secure knot tying even in fine gauges such as USP 2/0.

Absorption occurs by hydrolysis, a predictable process independent of the patient’s enzymatic activity, over a period of 56 to 72 days. This profile maintains the necessary tensile strength during the first 2 to 4 weeks of healing, while the tissue recovers its own resistance. The half-circle cylindrical needle with taper point of 36 mm penetrates by separating the fibres without cutting them, minimising trauma to delicate structures; it is therefore especially recommended in ophthalmic surgery, soft tissue approximation and ligatures. The undyed colour of the thread offers maximum aesthetic discretion in the surgical field. Sterile product by ethylene oxide, with no possibility of re-sterilisation.

Technical specifications

Technical data sheet for reference 1L23HR3620

Characteristic Specification
Reference (SKU) 1L23HR3620
Brand / Quality Premisut – Normal
Material Polyglactin 910 (PGLA), copolymer of 90 % glycolide and 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 2/0 (metric 3)
Thread colour Undyed (violet version available: ref. 1L13HR3620)
Thread length 90 cm
Needle shape ½ circle
Needle body Cylindrical
Needle tip Taperpoint
Needle size 36 mm (HR 36)
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO), sterile, single-use
Tissue reaction Minimal
Indications Approximation of soft tissues, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes

Tensile strength retention profile

Period after implantation Retained tensile strength
2 weeks 75 % of initial tensile strength
3 weeks 50 % of initial tensile strength
4 weeks 30% of initial tensile strength
Total absorption 56-72 days, by hydrolysis

Absorption occurs by hydrolysis between 56 and 72 days, with a predictable rate, minimal tissue reaction, excellent tensile strength and optimal knot tying.

Gauge equivalence

USP size Metric size Approximate diameter
2/0 3 0.30 – 0.339 mm (indicative according to Pharmacopoeia)

Equivalences and cross-references

Polyglactin 910 is one of the most well-established synthetic absorbable multifilament suture raw materials on the market. This braided, medium-absorption suture is clinically equivalent, in composition, absorption profile and mechanical behaviour, to the reference lines of other commercial brands:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided polyglactin 910)
B. Braun Safil (braided polyglactin 910)
Medtronic / Covidien Polysorb (absorbable braided range)
SMI Surgicryl (polyglactin 910)
Assut Assucryl 910
Laboratory Aragó Polyglactin 910 range with ½ circle cylindrical needles (HR series)

Within the Cahnos catalogue, its direct equivalent with the same configuration (HR 36 mm needle, USP 2/0 gauge, 90 cm thread) is reference 1L13HR3620 in violet for greater visibility in the field; the superior Prime quality is processed as P1L23HR3620. In the polyglycolic acid (PGA, absorption 60-90 days) family, the alternative is AM123HR3620. The equivalences indicated are for guidance; for a formal substitution of references, consult our technical-commercial department.

Selection tips and variants of interest

The USP 2/0 gauge offers an optimal balance between strength and fineness, indicated for soft tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures of medium-calibre vessels. The half-circle taper point needle of 36 mm is atraumatic; if you need to penetrate firmer, denser tissues (skin, fascia, sclera), consider the reverse cutting (HS) or trocar (HRT) points available in the same range.

Reference Variant
1L23HR3620 PGLA USP 2/0, HR 36 mm needle, undyed, 90 cm (current product)
1L13HR3620 PGLA USP 2/0, HR 36 mm needle, violet, 90 cm (greater visibility in the field)
P1L23HR3620 PGLA Prime USP 2/0, HR 36 mm needle, undyed, 90 cm (superior quality)
1L28HR3620 PGLA USP 2/0, HR 36 mm needle, undyed, 70 cm (shorter thread length)
1L23HR3610 PGLA USP 0, HR 36 mm needle, colourless, 90 cm (larger gauge)
1L23HS3620 PGLA USP 2/0, triangular reverse cutting needle HS 36 mm, undyed (firm tissues)
2L23HS3620 PGLA Rapid USP 2/0, absorption 40-45 days (earlier loss of strength)

All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. If you need longer strength retention (180-210 days), consider the polydioxanone (PDO) family from Cahnos. As this is a sterile single-use product, check the integrity of the packaging before each procedure, respect the expiry date and store the suture in a cool, dry place, protected from sunlight. For special B2B conditions by volume or equivalences from other commercial brands, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90% glycolide / 10% L-lactide

Thread structure

Braided multifilament with grooved finish

USP size

2/0 (metric 3)

Needle body

Cylindrical

Needle tip

Taperpoint

Needle size

36 mm (HR 36)

Retained tensile strength

75% at 2 weeks, 50% at 3 weeks, 30% at 4 weeks

Sterilisation

Ethylene oxide (EO), single-use

Tissue reaction

Minimal

Indications

Approximation of soft tissues, ligatures and ophthalmic surgery

Brand

Premisut (Laboratory Aragó)

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 36

Usp

2/0

Color

Colourless

Medida de hilo

90 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Suture (Polyglactin 910) Premisut | Half-Circle Cylindrical Taperpoint Needle HR 36 mm | USP 2/0 Gauge (Metric 3) | Undyed Thread 90 cm | Ref. 1L23HR3620 – Box of 12 units”

Your email address will not be published. Required fields are marked *