We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice
Sale!

Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture | 1/2 Circle Cylindrical Taperpoint Needle HR 48 mm | USP 0 Gauge | Violet Thread 75 cm | Ref. P1L12HR4810 – Box of 12 units

Original price was: 34,90 €.Current price is: 29,80 €.

Absorbable multifilament suture of Polyglactin 910 (PGLA) in Prime quality (range Premisut), reference P1L12HR4810. It features a ½ circle needle, cylindrical body and conical point (Taperpoint) of 48 mm (HR 48), USP 0 gauge (metric 3.5) and violet thread of 75 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction, excellent tensile strength and optimal knot security. Ideal for approximation of tissues, ligatures and ophthalmic surgery. Presentation in a box of 12 units; minimum order of 30 boxes.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L12HR4810

Description

1. Introduction

The absorbable multifilament suture of Polyglactin 910 (PGLA) in Prime quality from the Premisut range is the reference choice in the operating theatre for hospitals, private clinics, ophthalmologists and purchasing centres seeking a high-performance synthetic thread with a very competitive price-quality ratio.

This presentation combines a ½ circle needle, cylindrical body and conical point (Taperpoint) of 48 mm (HR 48), USP 0 gauge and violet thread of 75 cm. Each unit is supplied sterile and ready to use, with the professional distribution warranty of Cahnos. It is especially indicated for the approximation of soft tissues, ligatures and ophthalmic surgery, where precision, manageability and totally predictable absorption are required during the first weeks of healing.

2. Technical explanation

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide. Its multifilament braided structure with a grooved finish gives it great flexibility, low memory and a contained friction coefficient, which favours the sliding of the thread through the tissue and a firm and secure knot tying.

Absorption occurs by hydrolysis, that is, by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, maintaining wound support during the critical 2 to 4 weeks. It presents minimal tissue reaction and excellent tensile strength. The ½ circle needle with cylindrical body and conical point passes through tissues separating the fibres without cutting them, which minimises trauma to delicate structures. The violet colour guarantees optimal visibility in the surgical field. Sterilisation by ethylene oxide; sterile single-use product, with no possibility of re-sterilisation.

3. Technical Specifications

3.1. Technical data sheet

Characteristic Specification
Reference (SKU) P1L12HR4810
Quality Prime (Premisut range)
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Colour Violet
Gauge USP 0 (metric 3.5)
Thread length 75 cm
Needle shape 1/2 circle
Needle body Cylindrical
Needle tip Conical (Taperpoint)
Needle size 48 mm (HR 48 Prime)
Absorption mechanism Hydrolysis
Absorption period 56-72 days
Sterilisation Ethylene oxide (EO), single-use
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery

3.2. Tensile strength retention profile

Time after implantation Retained tensile strength
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days by hydrolysis

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a totally predictable absorption rate.

3.3. Presentation and ordering conditions

Value Value
Reference (SKU) P1L12HR4810
Presentation Box of 12 units
Minimum order 30 boxes
Format Sterile, single-use

4. Equivalences and Cross-References

This multifilament Polyglactin 910 suture belongs to the family of synthetic braided absorbable sutures of medium absorption, clinically equivalent in composition, absorption profile and mechanical behaviour to the reference lines of the international market:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl / Vicryl Plus (braided polyglactin 910, violet)
B. Braun Safil (braided polyglactin 910, violet)
Medtronic / Covidien Polysorb (absorbable braided range of polyglactin 910)
SMI Surgicryl (braided polyglactin 910, violet)
Laboratory Aragó Polyglactin 910 range with 1/2 circle needles (HR series)

The ½ circle format with cylindrical body and conical point of 48 mm corresponds to the classic pattern of taper-type needles of medium gauge used in general surgery, gynaecology, abdominal wall and ophthalmology. Within the Cahnos catalogue, this reference is directly related to:

  • P1L13HR4810 – same Prime quality, USP 0 gauge and HR 48 mm needle, with violet thread of 90 cm.
  • AMP113HR4810 – alternative in the PGA family (polyglycolic acid) with the same HR 48 mm needle, USP 0 and violet (absorption 60-90 days).
  • P1L12HR4820 – same configuration with USP 2/0 gauge for more delicate tissues.
  • P1L15HR48L10 – same HR 48 mm needle in loop format with thread of 150 cm.
  • P1L13HR4010 – same quality and gauge with a shorter 40 mm needle (HR 40).

The indicated equivalences are for guidance; for a formal substitution, consult our technical-commercial department.

5. Selection tips and variants of interest

The USP 0 gauge (metric 3.5) is very versatile: suitable for subcutaneous tissue, superficial muscle planes, approximation of soft tissues and ophthalmic surgery procedures, with an excellent balance between initial strength and predictable absorption during healing of 2 to 4 weeks.

In ophthalmic surgery, prioritise ½ circle needles: the conical point (Taperpoint) separates the fibres without cutting them, ideal for soft and delicate tissues; the blunt point offers maximum atraumaticity (see P1L13HRN4810) and the trocar point is reserved for fibrous and dense structures such as the sclera (reference P1L18HRT4810). Verify the needle radius (HR 40 or 48 mm) according to the depth and the surgical area to be treated.

For longer strength retention needs (180-210 days), the polydioxanone (PDO) family is the recommended alternative. As it is a sterile single-use product, always check the integrity of the packaging before each procedure and respect the traceability required by the centre. Consult our technical-commercial team for special volume conditions: the minimum order is 30 boxes, with scheduled deliveries for hospitals, clinics and purchasing centres.

Additional information

Reference

P1L12HR4810

Product line

Prime (Premisut range)

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 0 (metric 3.5)

Needle body

Cylindrical

Needle tip

Conical (Taperpoint)

Needle size

48 mm (HR 48)

Absorption mechanism

Hydrolysis (56-72 days)

Strength retention

75% at 2 weeks, 50% at 3, 30% at 4

Sterilisation

Ethylene oxide (EO), single-use

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HR 48

Usp

0

Color

Violet

Medida de hilo

75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA (Polyglactin 910) Prime Suture | 1/2 Circle Cylindrical Taperpoint Needle HR 48 mm | USP 0 Gauge | Violet Thread 75 cm | Ref. P1L12HR4810 – Box of 12 units”

Your email address will not be published. Required fields are marked *