Description
1. Commercial Introduction
The absorbable multifilament polyglactin 910 (PGLA) suture from the Prime PreMiSut range, reference P1L18HS2230, is the professional reference solution for B2B supply to operating theatres, ophthalmology clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its ½ circle needle with triangular reverse cutting point of 22 mm (HS 22) ensures firm and controlled penetration even in dense tissues, while the 70 cm violet fluted thread offers optimal visibility over the surgical field and smooth sliding during suturing. It is a synthetic, absorbable, sterile and single-use medical device, with an excellent quality-price ratio for the institutional channel.
2. Technical explanation of the product and procedure
Polyglactin 910 (PGLA) is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine sizes such as USP 3/0 (metric 2).
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing while the tissue recovers its own resistance. The ½ circle needle with triangular body and reverse cutting point (inverted triangle) penetrates firm, non-compliant tissues with controlled trauma, avoiding tears, which is why it is particularly indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L18HS2230
| Parameter | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Range / Quality | Prime (PreMiSut Prime) |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Violet grooved |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (inverted triangular) |
| Needle size | HS 22 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (single-use) |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HS2230 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days by hydrolysis |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic / Covidien | Polysorb (absorbable braided range of polyglactin 910) |
| SMI | Surgicryl (absorbable braided polyester of equivalent profile) |
| Laboratorio Aragó (range PreMiSut) | Multifilament polyglactin 910 with ½ circle needle (HS series) |
Within the catalogue of Cahnos, this Prime reference has its direct equivalent in the standard range, in colourless version and in PGA (polyglycolic acid) material:
| Reference | Description |
| P1L28HS2230 | PGLA Prime, triangular needle HS 22 mm, USP 3/0, colourless, 70 cm (same configuration, colourless thread) |
| 1L18HS2230 | PGLA Normal quality, HS 22 mm, USP 3/0, violet, 70 cm (standard range) |
| 1L28HS2230 | PGLA Normal quality, HS 22 mm, USP 3/0, colourless, 70 cm (colourless standard range) |
| AMP118HS2230 | PGA (polyglycolic acid), HS 22 mm, USP 3/0, violet, 70 cm (absorption from 60 to 90 days) |
5. Selection tips and variants of interest
The USP 3/0 (metric 2) size is indicated for fine tissues with moderate tension: skin, mucosa, subcutaneous tissue, intradermal sutures and ophthalmic surgery, as well as for precision ligatures. The triangular reverse cutting point needle (HS 22) is recommended when firm, non-compliant tissues need to be penetrated without tearing; the ½ circle shape is ideal in confined or limited-access spaces. In the Prime range of Cahnos the following interesting variants are offered:
| Reference | Variant |
| P1L18HS2230.2 | PGLA Prime, HS 22 mm, USP 3/0, violet, double strand 2×70 cm (more autonomy per sachet) |
| P1L18HS2220 | PGLA Prime, HS 22 mm, USP 2/0, violet, 70 cm (finer size, greater delicacy) |
| P1L18HS2630 | PGLA Prime, HS 26 mm, USP 3/0, violet, 70 cm (larger needle size) |
| P1L28HS2630 | PGLA Prime, HS 26 mm, USP 3/0, colourless, 70 cm (maximum aesthetic discretion) |
| P1L18HS3630 | PGLA Prime, HS 36 mm, USP 3/0, violet, 70 cm (longer needle for deep access) |
| P1L12HR2230.2 | PGLA Prime, cylindrical needle HR 22 mm, USP 3/0, violet, 2×75 cm (atraumatic conical point) |
If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units with a minimum order of 30 boxes, ensuring continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.