Multifilament Absorbable Suture PGLA (Polyglactin 910) | ½ Circle Needle Triangular Point Reverse Cutting HS 26 mm | Gauge USP 1 (Metric 4) | Colourless Fluted Thread 70 cm | Ref. 1L28HS2601 – Box of 12 units

Original price was: 34,90 €.Current price is: 27,40 €.

Multifilament absorbable suture of polyglactin 910 (PGLA) from the PREMISUT range, reference 1L28HS2601, with ½ circular needle with triangular reverse cutting point of 26 mm (HS 26), gauge USP 1 (metric 4) and colourless fluted thread of 70 cm. Predictable absorption by hydrolysis between 56 and 72 days, with tensile strength retention of 75 % at 2 weeks, 50 % at 3 and 30 % at 4. Sterile by ethylene oxide, single-use and with minimal tissue reaction. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in a box of 12 units, with a minimum order of 30 boxes for institutional B2B supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
1L28HS2601

Description

1. Commercial Introduction

The multifilament absorbable suture of polyglactin 910 (PGLA) from the PREMISUT range, reference 1L28HS2601, is the reference technical solution for the professional seeking a surgical thread with predictable behaviour, excellent handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery. Its ½ circular needle with triangular reverse cutting point of 26 mm (HS 26) offers firm and controlled penetration even in non-compliant tissues, while the colourless fluted thread of 70 cm guarantees optimal visibility of the surgical field in delicate procedures and smooth sliding during suturing.

It is a synthetic, absorbable, sterile and single-use medical device, with a very competitive price-quality ratio for B2B supply to operating theatres, ophthalmology clinics and purchasing centres. Commercial presentation in a box of 12 units and minimum order of 30 boxes, ensuring continuous supply for your healthcare centre.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that favours the passage of the thread through tissue, smooth handling and firm, secure knot tying in medium gauges such as USP 1 (metric 4).

Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days, maintaining the necessary tensile strength during the first weeks of healing while the tissue recovers its own resistance. The ½ circle needle with triangular body and reverse cutting point of 26 mm penetrates firm tissues with controlled trauma and avoids tearing, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference 1L28HS2601

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Gauge USP 1 (metric 4)
Thread colour Colourless
Needle shape ½ circle
Tip type Triangular with reverse cutting (triangular body and point)
Needle size HS 26 mm
Thread length 70 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (single-use)
Tissue reaction Minimal
Indications Tissue approximation, ligatures and ophthalmic surgery
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) 1L28HS2601

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %
Complete absorption 56-72 days (hydrolysis)

Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Price per box of 12 units.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic Absorbable braided polyglactin 910 range
Laboratory Aragó Premisut range of polyglactin 910 with ½ circle needles (HS / HR series)

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 1 (metric 4) gauge is ideal for tissues with moderate-high tension, such as fascia, aponeurosis, abdominal wall and ligatures of medium-calibre vessels. The 26 mm triangular reverse cutting needle is especially recommended in firm tissues and in ophthalmic surgery, where the needle passage must be clean and without tearing. Polyglactin 910 offers an excellent balance between initial strength and predictable absorption for soft tissues with healing of 2 to 4 weeks.

Reference Variant
1L28HS2601 PGLA USP 1, triangular needle HS 26 mm, colourless, 70 cm (current product)
1L28HR2601 PGLA USP 1, cylindrical needle HR 26 mm, colourless, 70 cm (atraumatic conical point)
1L28HS2610 PGLA USP 0, triangular needle HS 26 mm, colourless, 70 cm (smaller gauge)
1L28HS2620 PGLA USP 2/0, triangular needle HS 26 mm, colourless, 70 cm (finer gauge)
P1L28HS2601 PGLA Prime USP 1, triangular needle HS 26 mm, colourless, 70 cm (premium range)
AMP128HS2601 PGA polyglycolic acid USP 1, HS 26 mm needle (absorption of 60 to 90 days)
1L18HS3601 PGLA USP 1, triangular needle HS 36 mm, violet, 70 cm (larger needle, dyed thread)

If you require a longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in a box of 12 units; the minimum order is 30 boxes to ensure continuous supply for your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Gauge

USP 1 (metric 4)

Tip type

Reverse cutting triangular (reverse cutting)

Sterilisation

Ethylene oxide (single-use)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Medida de aguja

HS 26

Usp

1

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Normal

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Multifilament Absorbable Suture PGLA (Polyglactin 910) | ½ Circle Needle Triangular Point Reverse Cutting HS 26 mm | Gauge USP 1 (Metric 4) | Colourless Fluted Thread 70 cm | Ref. 1L28HS2601 – Box of 12 units”

Your email address will not be published. Required fields are marked *