Description
1. Commercial Introduction
The absorbable multifilament suture of poliglactin 910 (PGLA) from the Premisut Prime range, reference P1L18HS2230.2, is the professional reference solution for B2B supply to operating theatres, ophthalmology clinics and purchasing centres. It combines a synthetic copolymer with predictable behaviour, exceptional handling and excellent knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its half-circle needle with a 22 mm triangular reverse cutting point (HS 22) ensures firm and controlled penetration even in dense tissues, while the presentation as a double strand of 70 cm in fluted violet offers optimal visibility on the surgical field, smooth passage during suturing and greater autonomy per sachet. It is a synthetic absorbable medical device, sterile and single-use, with an excellent quality-price ratio.
2. Technical explanation of the product and procedure
Poliglactin 910 is a synthetic absorbable copolymer composed of 90 % glycolide and 10 % L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying, even in fine gauges such as USP 3/0 (metric 2).
Absorption occurs by hydrolysis, i.e., by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The half-circle needle with triangular body and reverse cutting point (inverted triangle) of 22 mm penetrates firm and non-compliant tissues with controlled trauma, avoiding tears, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L18HS2230.2
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Range / Quality | Prime (Premisut Prime) |
| Gauge | USP 3/0 (metric 2) |
| Thread colour | Violet grooved |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (triangular body and point) |
| Needle size | HS 22 mm |
| Thread length | 2 x 70 cm (double strand per sachet) |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO), single-use |
| Tissue reaction | Minimal |
| Indications | Tissue approximation, ligatures and ophthalmic surgery |
| Presentation | Box of 12 units (sachets with 2 strands of 70 cm) |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L18HS2230.2 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
| Complete absorption | 56-72 days (hydrolysis) |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery.
4. Equivalences and Cross-References
This multifilament poliglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with ½ circle needles (HS / TC series) |
Within the Cahnos catalogue, its direct equivalent in the same needle, gauge and colour configuration in the standard range is reference 1L18HS2230 (triangular needle HS 22 mm, USP 3/0, violet, 70 cm), and in the polyglycolic acid (PGA) family, the AMP118HS2230 stands out, recommended when an absorption profile of 60 to 90 days is preferred. The version with a single strand of 70 cm is supplied as P1L18HS2230.
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the gauge needed according to the anatomical area. The USP 3/0 (metric 2) gauge is indicated for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general. The 22 mm triangular reverse cutting needle is especially recommended in firm and non-compliant tissues, as well as in ophthalmic surgery, where the passage of the needle must be clean and without tears. The double-strand presentation of 70 cm optimises the use of the sachet in procedures with multiple suture points.
Variants of interest in the Cahnos catalogue:
- P1L18HS2230: same configuration with 1 strand of 70 cm (standard presentation).
- P1L18HS2220: PGLA Prime HS 22 mm, gauge 2/0, violet, 70 cm (finer needle for delicate tissues).
- P1L18HS2630: PGLA Prime HS 26 mm, USP 3/0, violet, 70 cm (larger needle).
- P1L18HS3630: PGLA Prime HS 36 mm, USP 3/0, violet, 70 cm (longer needle for deep access).
- P1L12HR2230.2: PGLA Prime cylindrical HR 22 mm, USP 3/0, violet, 2×75 cm (conical point for soft tissues).
- P1L28HS2630: same configuration in colourless thread (greater aesthetic discretion).
If you need a longer force retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare centre. For special B2B conditions and volume orders, contact our technical-commercial team.