Absorbable Multifilament PGLA Polyglactin 910 Prime Suture | 1/2 Circle Reverse Cutting Triangular Point Needle HS 26 mm | USP 2/0 (Metric 3) Gauge | Colourless 70 cm | Ref. P1L28HS2620 – Box of 12 units

Original price was: 39,90 €.Current price is: 32,60 €.

Absorbable multifilament polyglactin 910 (PGLA) Prime suture, reference P1L28HS2620, with ½ circular needle with reverse cutting triangular point of 26 mm (HS 26), USP 2/0 (metric 3) gauge and 70 cm colourless fluted thread. Synthetic copolymer of 90% glycolide and 10% L-lactide with predictable hydrolysis absorption between 56 and 72 days and tensile strength retention of 75% at 2 weeks, 50% at 3 and 30% at 4. Sterile by ethylene oxide, minimal tissue reaction and excellent knot security. Indicated for tissue approximation, ligatures and ophthalmic surgery. Presentation in a box of 12 units with a minimum order of 30 boxes for institutional supply.

Se fabrica bajo pedido: el fabricante exige un mínimo de 30 boxes por referencia.

International shipping. Import duties and taxes are payable by the recipient.

Reference
P1L28HS2620

Description

1. Introduction

The absorbable multifilament suture of polyglactin 910 (PGLA) from the Prime range, reference P1L28HS2620, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, purchasing centres and ambulatory surgery units. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.

Its ½ circle needle with reverse cutting triangular point of 26 mm (HS 26) ensures firm, controlled penetration even in dense, non-compliant tissues, while the 70 cm colourless fluted thread offers smooth sliding during suturing. It is a synthetic absorbable medical device, sterile, single-use and with an excellent quality-price ratio.

2. Technical explanation of the product and procedure

Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying in medium gauges such as USP 2/0 (metric 3).

Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with reverse cutting triangular point penetrates firm tissues with controlled trauma, avoiding tearing, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.

3. Technical Specifications

3.1. General characteristics of reference P1L28HS2620

Characteristic Specification
Material Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide
Thread structure Braided multifilament with grooved finish
Quality Prime (range PREMISUT)
Gauge USP 2/0 (metric 3)
Thread colour Colourless
Needle shape ½ circle
Tip type Reverse cutting triangular (inverted triangular)
Needle size HS 26 mm
Thread length 70 cm
Absorption mechanism Hydrolysis (56-72 days)
Sterilisation Ethylene oxide (EO)
Tissue reaction Minimal
Presentation Box of 12 units
Minimum order 30 boxes
Reference (SKU) P1L28HS2620

3.2. Tensile strength retention profile

Time Tensile strength retention
2 weeks 75 %
3 weeks 50 %
4 weeks 30 %

Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.

4. Equivalences and Cross-References

This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:

Manufacturer / Company Equivalent line
Ethicon (Johnson & Johnson) Vicryl (coated braided polyglactin 910, violet colour)
B. Braun Safil (braided polyglactin 910, violet colour)
Medtronic Polysorb (absorbable braided range of polyglactin 910)
Laboratory Aragó Polyglactin 910 range with 1/2 circle needles (C / TC / HS series)

Within the Cahnos catalogue, its direct equivalent in gauge and material within the same PGLA Prime range is reference P1L28HR2620 (same USP 2/0, colourless 70 cm thread, with HR 26 mm cylindrical needle with conical point, more atraumatic). In the polyglycolic acid family, the equivalent reference by structure and needle is AMP128HS2620 (PGA, HS 26 mm triangular needle, USP 2/0, with an absorption profile of 60 to 90 days).

5. Selection tips and variants of interest

To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2/0 (metric 3) is ideal for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures. The 26 mm reverse cutting triangular needle is especially recommended for firm tissues and in ophthalmic surgery, where the needle passage must be clean and without tearing.

Reference Variant
P1L28HS2620 PGLA Prime USP 2/0, HS 26 mm triangular needle, colourless, 70 cm (current product)
P1L28HR2620 PGLA Prime USP 2/0, HR 26 mm cylindrical needle, colourless, 70 cm (conical point, more atraumatic)
P1L28HS2610 PGLA Prime USP 0, same needle HS 26 mm, undyed, 70 cm (smaller gauge)
P1L28HS2601 PGLA Prime USP 1, same HS 26 mm needle, colourless, 70 cm (larger gauge)
P1L18HS2610 PGLA Prime USP 0, HS 26 mm needle, violet, 70 cm (dyed thread for greater visibility)
AMP128HS2620 PGA Prime USP 2/0, HS 26 mm needle (absorption profile of 60 to 90 days)

If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.

Additional information

Material

Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide

Thread structure

Braided multifilament with grooved finish

Quality

Prime (range PREMISUT)

USP size

2/0 (metric 3)

Tip type

Reverse cutting triangular (inverted triangular)

Tensile strength

75 % (2 weeks), 50 % (3 weeks), 30 % (4 weeks)

Sterilisation

Ethylene oxide (EO)

Tissue reaction

Minimal

Indications

Tissue approximation, ligatures and ophthalmic surgery

Presentation

Box of 12 units

Minimum order

30 boxes

Reference

P1L28HS2620

Medida de aguja

HS 26

Usp

2/0

Color

Colourless

Medida de hilo

70 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Prime

Absorcion

Absorbable medium (46–120 days)

Reviews

There are no reviews yet.

Be the first to review “Absorbable Multifilament PGLA Polyglactin 910 Prime Suture | 1/2 Circle Reverse Cutting Triangular Point Needle HS 26 mm | USP 2/0 (Metric 3) Gauge | Colourless 70 cm | Ref. P1L28HS2620 – Box of 12 units”

Your email address will not be published. Required fields are marked *