Description
1. Introduction
The absorbable multifilament suture of polyglactin 910 (PGLA) from the Prime range, reference P1L28HS2620, is the professional reference solution for B2B supply to operating theatres, ophthalmic clinics, purchasing centres and ambulatory surgery units. It combines a synthetic copolymer with predictable behaviour, exceptional handling and great knot security in the approximation of soft tissues, ligatures and ophthalmic surgery.
Its ½ circle needle with reverse cutting triangular point of 26 mm (HS 26) ensures firm, controlled penetration even in dense, non-compliant tissues, while the 70 cm colourless fluted thread offers smooth sliding during suturing. It is a synthetic absorbable medical device, sterile, single-use and with an excellent quality-price ratio.
2. Technical explanation of the product and procedure
Polyglactin 910 is a synthetic absorbable copolymer composed of 90% glycolide and 10% L-lactide, presented in a braided multifilament structure with a fluted finish. This configuration provides a regular surface that facilitates the passage of the thread through tissue, smooth handling and firm, secure knot tying in medium gauges such as USP 2/0 (metric 3).
Absorption occurs by hydrolysis, i.e. by degradation of the polymer in contact with organic fluids, over a predictable period of 56 to 72 days. This profile maintains the necessary tensile strength during the first weeks of healing, while the tissue recovers its own resistance. The ½ circle needle with reverse cutting triangular point penetrates firm tissues with controlled trauma, avoiding tearing, which is why it is especially indicated for tissue approximation, ligatures and ophthalmic surgery procedures. The product is supplied sterile by ethylene oxide, single-use and cannot be re-sterilised.
3. Technical Specifications
3.1. General characteristics of reference P1L28HS2620
| Characteristic | Specification |
| Material | Polyglactin 910 (PGLA), copolymer 90 % glycolide / 10 % L-lactide |
| Thread structure | Braided multifilament with grooved finish |
| Quality | Prime (range PREMISUT) |
| Gauge | USP 2/0 (metric 3) |
| Thread colour | Colourless |
| Needle shape | ½ circle |
| Tip type | Reverse cutting triangular (inverted triangular) |
| Needle size | HS 26 mm |
| Thread length | 70 cm |
| Absorption mechanism | Hydrolysis (56-72 days) |
| Sterilisation | Ethylene oxide (EO) |
| Tissue reaction | Minimal |
| Presentation | Box of 12 units |
| Minimum order | 30 boxes |
| Reference (SKU) | P1L28HS2620 |
3.2. Tensile strength retention profile
| Time | Tensile strength retention |
| 2 weeks | 75 % |
| 3 weeks | 50 % |
| 4 weeks | 30 % |
Complete absorption by hydrolysis between 56 and 72 days. Minimal tissue reaction, excellent tensile strength and optimal knot tying, with a fully predictable absorption rate. Indicated for tissue approximation, ligatures and ophthalmic surgery. Price per box of 12 units.
4. Equivalences and Cross-References
This multifilament polyglactin 910 suture is clinically positioned in the same family as the reference synthetic absorbable braided sutures on the international market, commonly used in general surgery, ophthalmology, gynaecology and urology:
| Manufacturer / Company | Equivalent line |
| Ethicon (Johnson & Johnson) | Vicryl (coated braided polyglactin 910, violet colour) |
| B. Braun | Safil (braided polyglactin 910, violet colour) |
| Medtronic | Polysorb (absorbable braided range of polyglactin 910) |
| Laboratory Aragó | Polyglactin 910 range with 1/2 circle needles (C / TC / HS series) |
Within the Cahnos catalogue, its direct equivalent in gauge and material within the same PGLA Prime range is reference P1L28HR2620 (same USP 2/0, colourless 70 cm thread, with HR 26 mm cylindrical needle with conical point, more atraumatic). In the polyglycolic acid family, the equivalent reference by structure and needle is AMP128HS2620 (PGA, HS 26 mm triangular needle, USP 2/0, with an absorption profile of 60 to 90 days).
5. Selection tips and variants of interest
To choose the most suitable suture, consider the wound support time required by the tissue to be sutured and the necessary gauge according to the anatomical area. USP 2/0 (metric 3) is ideal for tissues with moderate tension: skin, subcutaneous tissue, mucosa, fascia and soft tissue in general, as well as for ligatures. The 26 mm reverse cutting triangular needle is especially recommended for firm tissues and in ophthalmic surgery, where the needle passage must be clean and without tearing.
| Reference | Variant |
| P1L28HS2620 | PGLA Prime USP 2/0, HS 26 mm triangular needle, colourless, 70 cm (current product) |
| P1L28HR2620 | PGLA Prime USP 2/0, HR 26 mm cylindrical needle, colourless, 70 cm (conical point, more atraumatic) |
| P1L28HS2610 | PGLA Prime USP 0, same needle HS 26 mm, undyed, 70 cm (smaller gauge) |
| P1L28HS2601 | PGLA Prime USP 1, same HS 26 mm needle, colourless, 70 cm (larger gauge) |
| P1L18HS2610 | PGLA Prime USP 0, HS 26 mm needle, violet, 70 cm (dyed thread for greater visibility) |
| AMP128HS2620 | PGA Prime USP 2/0, HS 26 mm needle (absorption profile of 60 to 90 days) |
If you need longer strength retention (180-210 days) or a monofilament profile, consider the polydioxanone (PDO) family from Cahnos. All references are supplied in boxes of 12 units; the minimum order is 30 boxes to ensure continuous supply to your healthcare facility. For special B2B conditions and volume orders, contact our technical-commercial team.





Reviews
There are no reviews yet.