Description
1. Commercial Introduction
The absorbable monofilament suture PREMISUT Poliglecaprone 25 (PGCL / caprolactone) from the Prime line is the technical choice when the procedure requires controlled resorption, minimal inflammatory response and particularly smooth passage of the thread through tissue. This presentation incorporates a ⅜ circle needle with an extra-long precision reverse cutting triangular point and a 13 mm square body (XDS 13 Prime profile), a cosmetic-type configuration designed for plastic, facial and delicate tissue surgery where controlled needle advancement is required without damaging the surrounding tissue.
The colourless thread in USP 4/0 gauge and 45 cm length is especially valued in intradermal sutures and subcutaneous closures, where minimal visibility of the material and its smooth passage make the difference in the aesthetic result. Sterile single-use product, ready for the operating theatre and presented in a box of 12 units with batch traceability.
2. Technical explanation
Poliglecaprone 25 is a synthetic copolymer of glycolide and ε-caprolactone that degrades by hydrolysis, without enzymatic activity, ensuring predictable absorption and minimal tissue reaction. As a non-barbed monofilament, it reduces bacterial carriage compared with multifilament sutures and facilitates sliding and the formation of secure knots.
- Absorption: by complete hydrolysis, with total mass loss between 90 and 120 days.
- Tensile strength retention: approximately 60 % at the first week and 30 % at the second, covering the critical healing phase.
- Needle: ⅜ circle, XDS precision reverse cutting triangular point with 13 mm square body, designed for firm penetration with minimal resistance and optimal needle holder control in firm tissues such as skin and aponeurosis.
- Indications: approximation of soft tissues and ligatures in general, dermatological, plastic and reconstructive surgery, as well as in delicate tissues where a fine gauge with a balance between strength and minimal footprint is required.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Material | Poliglecaprone 25 (PGCL) · copolymer of glycolide and ε-caprolactone |
| Structure | Synthetic absorbable monofilament, non-barbed |
| Absorption mechanism | Complete hydrolysis |
| Absorption time | 90 – 120 days |
| Tensile strength retention | ≈ 60 % at 1 week · ≈ 30 % at 2 weeks |
| USP size | 4/0 (metric EP 1.5) |
| Thread length | 45 cm (1 thread · 1 needle per unit) |
| Colour | Colourless (also available in violet depending on reference) |
| Needle shape | ⅜ circle (3/8 circular) |
| Needle tip | Precision reverse cutting triangular (XDS, Reverse Extra Cutting) |
| Needle body / section | Square (13 mm length), cosmetic configuration |
| Sterilisation | Ethylene oxide (EO); sterile, single-use product |
| Quality | Prime |
| Indications | Approximation of tissues and ligatures; plastic, cosmetic and facial surgery |
| Presentation | Box of 12 sterile units · Minimum order 10 boxes |
| Factory reference | P321XDS1340 |
| SKU Cahnos | AMP321XDS1340 |
4. Equivalences and Cross-References
Poliglecaprone 25 is a family widely established on the international market, where the clinical reference of the category is the MONOCRYL® line from Ethicon. For this specific format (USP 4/0, colourless, monofilament, ⅜ circle reverse cutting needle and 45 cm thread), the following reference, comparable by category (not interchangeable 1:1 due to the geometry of the needle body, without cosmetic square body), has been verified against the manufacturer’s official catalogue and authorised distribution sources.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | MONOCRYL® (poliglecaprone 25) | Y496G | Comparable by category (not interchangeable 1:1) | MONOCRYL 4/0, 45 cm, colourless monofilament; PS-2 ⅜ circle precision reverse cutting needle of 19 mm (without square body). Same polymer base, gauge, length and 90-120 day absorption profile; needle geometry and size differ (standard PS-2 19 mm versus extra-long XDS 13 mm with square body). |
| DemeTECH | Poliglecaprone 25 (PGCL) | Y496D | Comparable by category (not interchangeable 1:1) | PGCL 4/0, 45 cm (18″), colourless; DPS-2 ⅜ circle reverse cutting needle of 19 mm. Same polymer base and 90-120 day absorption profile; different needle geometry (19 mm, without square body). |
There is no equivalence table validated by the manufacturer for this specific reference; consult the technical department before use in tenders. The factory reference P321XDS1340 does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in specifications. Other homologous poliglecaprone 25 lines on the market (for example, MONOCRYL® Plus Antibacterial from Ethicon with triclosan, or those from Assut Medical and SMI) require case-by-case verification of needle geometry, exact material and colour before any substitution; the antibacterial load, where applicable, represents a relevant functional difference.
5. Selection tips and variants of interest
- USP 4/0 gauge: indicated for fine and delicate tissues (dermis, subcutaneous tissue, mucosa) where minimal reaction and good knot strength are sought.
- XDS needle: the extra-long precision reverse cutting with square body is the cosmetic variant of the family; its square body improves grip in the needle holder and reduces rotation, ideal for plastic, facial and dermatological surgery and delicate tissues.
- Variants of the same family in Cahnos: the PREMISUT PGCL range offers the same XDS configuration in 16 mm (SKU AMP321XDS1640), 19 mm (SKU AMP321XDS1940) and 24 mm (SKU AMP321XDS2440), maintaining gauge 4/0 and 45 cm; for a finer gauge there is the 5/0 with 13 mm XDS needle (SKU AMP321XDS1350) and for greater thread length versions of 70 cm.
- Longer absorption profile: if absorption over 180-210 days with a similar needle configuration is sought, the polydioxanone (PDO) family from the same line may be considered.
- Storage: keep in a cool, dry place, respecting the expiry date of the sterile packaging and checking the integrity of the blister before each use. Single-use material, not re-sterilisable.
Always verify the radius, needle size, USP gauge and point family required in your surgical protocol, as well as the current minimum order.





Reviews