Description
1. Commercial Introduction
We offer you the absorbable monofilament suture of poliglecaprone 25 (PGCL / caprolactone) from the PREMISUT Prime range, factory reference P322DS2420.2 (SKU Cahnos AMP322DS2420.2), in a professional double-strand presentation: 2 colourless grooved strands of 75 cm in USP 2/0 gauge, mounted on a ⅜ circle needle with a grooved reverse cutting triangular point of 24 mm (DS24 Prime profile). It is the ideal B2B supply solution for operating theatres, general and digestive surgery departments, gynaecology, urology and purchasing centres looking for a synthetic absorbable thread with exceptional handling, firm knot, minimal tissue reaction and complete batch traceability. Each unit is delivered sterile, ready for immediate use, in a box of 12 units in individual sachets.
2. Technical explanation of the material and procedure
Poliglecaprone 25 (PGCL) is a synthetic copolymer of poly(glycolic acid 75 % – co-caprolactone 25 %) in an uncoated monofilament structure. Its single-strand design reduces drag (saw effect) during passage through tissue, minimises capillarity and provides excellent handling smoothness and knot security compared with braided multifilaments.
Absorption occurs by controlled hydrolysis —a predictable mechanism independent of enzymatic activity— over a period of 90 to 120 days (medium absorption), with an approximate retention of the original strength of 60 % at 7 days and 30 % at 14 days after implantation, comfortably covering the critical healing phase of most soft tissues. It is not recommended when prolonged tissue support is required (e.g., fascia).
The DS24 needle of 24 mm, with ⅜ circle curvature and a grooved reverse cutting triangular point, concentrates the cutting edge on the outer side of the curvature: it penetrates firm, non-distensible tissues (skin, aponeurosis, dense subcutaneous tissue) with minimal resistance and better aesthetic results, preventing the cut from widening in the puncture bed. The double 2×75 cm presentation provides two strands per package for continuous or multi-point sutures without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. Technical data sheet for reference P322DS2420.2
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT Prime (premium range, grooved needle) |
| Factory reference | P322DS2420.2 |
| Reference Cahnos (SKU) | AMP322DS2420.2 |
| Thread material | Poliglecaprone 25 (PGCL) – copolymer 75 % glycolic acid / 25 % ε-caprolactone |
| Thread structure | Synthetic absorbable monofilament, grooved surface |
| Coating | Uncoated |
| Gauge / size | USP 2/0 (metric EP 3), conforming to USP and European Pharmacopoeia |
| Approximate thread diameter | 0.30 – 0.339 mm |
| Thread length | 2 × 75 cm (double strand, 150 cm per pouch) |
| Thread colour | Colourless (grooved) |
| Needle shape | 3/8 circle (⅜ circular), body and point |
| Tip type | Triangular reverse cutting (Reverse Cutting), grooved |
| Needle size | DS24 Prime (24 mm) |
| Swaged | 2 needles / 2 threads of 75 cm per unit |
| Absorption mechanism | Hydrolysis |
| Absorption period | 90 – 120 days (average absorption) |
| Sterilisation | Ethylene oxide (EO); sterile, single-use, non-resterilisable |
| Tissue reaction | Minimal |
| Indications | Soft tissue approximation and general ligatures |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Conforms to USP and European Pharmacopoeia (EP) gauges |
| Storage | Below 30 °C, away from moisture and direct sunlight |
3.2. Tensile strength retention profile
| Period after implantation | Tensile strength retention |
|---|---|
| 1 week | 60% of initial tensile strength |
| 2 weeks | 30% of initial tensile strength |
| Complete absorption | 90–120 days, by hydrolysis |
3.3. Gauge equivalence according to USP / EP Pharmacopoeia (absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 (this product) | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
4. Equivalences and Cross-References
Reference P322DS2420.2 corresponds to the official nomenclature of the PREMISUT Prime range (DS24 profile: ⅜ circle needle with reverse cutting triangular point of 24 mm, USP 2/0 gauge, colourless grooved thread of 75 cm, double 2×75 cm presentation) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Poliglecaprone 25 is one of the most standardised synthetic absorbable monofilaments of medium absorption on the international market, with the MONOCRYL® line from Ethicon (Johnson & Johnson MedTech) being the clinical reference of the category, along with homologous families such as MONOSYN® from B. Braun (based on gluconate, with different degradation kinetics) and the PGCL lines from DemeTECH (DemeCAPRONE), SMI (Caprofyl®), Healthium (Monoglyde®), Assut Medical, Dolphin Sutures (Petcryl Mono), WEGO and CP Medical. The following correspondences have been verified against the manufacturer’s official catalogue (EPC Ethicon) and authorised distribution, all comparable by category and not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | MONOCRYL® (poliglecaprone 25) colourless monofilament, USP 2/0, 70 cm, Prime needle of 24 mm, ⅜ circle, reverse cutting | Y684H | Comparable by category (not interchangeable 1:1) | Confirmed in the official Ethicon catalogue and authorised distribution: the polymer (poliglecaprone 25), monofilament structure, colourless colour, USP 2/0 gauge, ⅜ circle geometry, needle size 24 mm and reverse cutting point family coincide. The thread length (70 cm vs 75 cm) and the configuration (1 needle/1 thread vs double thread 2×75 cm) differ. Validate in the technical data sheet/IFU before substituting in a tender. |
| Ethicon (J&J MedTech) | MONOCRYL® Plus Antibacterial (poliglecaprone 25) colourless monofilament, USP 2/0, 70 cm, Prime needle of 24 mm, ⅜ circle, reverse cutting | MCP684H | Comparable by category (not interchangeable 1:1) | Confirmed in the official Ethicon catalogue and authorised distribution: same configuration 2/0 · 24 mm · 70 cm colourless with antibacterial coating (triclosan), absent in this reference. The antibacterial load represents a relevant functional difference. Validate IFU before substituting. |
There is no equivalence table validated by the manufacturer that cross-references this specific configuration (PGCL monofilament, DS24 needle of 24 mm reverse cutting, USP 2/0 gauge, colourless thread of 75 cm and double configuration 2×75 cm, ref. P322DS2420.2) with references from other houses in identical configuration; consult the technical department before using in a tender. The homologous families mentioned must be reviewed property by property (material, gauge, curvature, point family, length and number of strands, colour, coating and current CE/MDR regulatory classification) before any substitution. MONOCRYL® codes with a 26 mm needle (W3327 series and variants) fall outside the ±1 mm tolerance with respect to the DS24 needle of 24 mm and should not be used as a direct exchange. The factory reference of this article does not appear in public regulatory databases (GUDID/EUDAMED) and must be confirmed with the supplier before use in tender documents. The trademarks cited belong to their respective manufacturers and are mentioned only as comparative reference.
5. Selection tips and variants of interest
Tissue to suture: the USP 2/0 gauge (metric EP 3) with a 24 mm needle is suitable for approximating medium-thickness tissues: subcutaneous tissue, fascia, muscular wall, peritoneum and ligatures where strength is required during the first 2–3 weeks of healing. The reverse cutting point penetrates dense tissues without tearing the puncture bed and improves the aesthetic outcome.
Double-thread format: the 2×75 cm presentation reduces the number of envelopes opened per procedure in continuous sutures or those with multiple passes, ideal for high-turnover services; if you prefer a single strand, request the 1×75 cm variant of the same DS24 Prime profile (AMP322DS2420) or the standard quality (AM322DS2420).
Alternative gauges and needles in the same PGCL range: same DS24 profile in USP 3/0 (AMP322DS2430), DS26 profile in USP 2/0 double thread (AMP322DS2620.2) or single strand (AMP322DS2620 / AM322DS2620), DS26 profile in USP 3/0 double thread (AMP322DS2630.2) and DS30 profile in USP 3/0 (AMP322DS3030.2). All references are supplied in boxes of 12 units.
Absorption profile: if the procedure requires longer wound support, consider polydioxanone PDO (180–210 days); if a shorter absorption profile is needed, consider PGA (60–90 days) or polyglactin 910 (56–72 days).
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each procedure, keep the reference P322DS2420.2 and the batch number for traceability in the operating theatre, and store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.